Bryant 345MAVの取扱説明書

12ページ 0.15 mb
ダウンロード

ページに移動 of 12

Summary
  • Bryant 345MAV - page 1

    USER’S INFORMA TION MANU AL MODEL 345MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance. — Do not touch any electrical switch; do not use any phone in y our building. • Imm ...

  • Bryant 345MAV - page 2

    INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No . Model No . Serial No . INDOOR COIL: Product No . Model No . Serial No . 2 WELCOME T O A NEW GENERA TION OF COMFOR T Congratulations! In light of rising energy costs, the 345MA V Mu ...

  • Bryant 345MAV - page 3

    3 FURN A CE COMPONENTS Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating. Combustion-air intake connection (right or left side). Redundant gas valve. Safe, efficient. Features 1 gas control with 2 internal shutoff valves. Junction b ...

  • Bryant 345MAV - page 4

    4 IMPOR T ANT F A CTS Y our g as furnace uses air adjacent to the furnace for comb ustion and vents to the outside. Do not enclose it in an airtight room or seal it behind solid doors. It must hav e adequate airflow for ef ficient combustion and safe v entilation. The vent pipe must terminate outside the structure and must not be obstructed in an ...

  • Bryant 345MAV - page 5

    5 STEPS FOR ST AR TING Y OUR FURN A CE 1. Set your room thermostat to the lo w- est temperature setting. (See Fig. 6.) 6 7 8 2. Close the e xternal manual gas v alve. (See Fig. 7.) 3. T urn of f electrical supply to the fur - nace. (See Fig. 8.) 4. Remo ve the main furnace door . (See Fig. 9.) 5. Gas v alve will ha ve EITHER a con- trol switch or c ...

  • Bryant 345MAV - page 6

    6 14 15 16 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 17 18 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting. (See Fig. 17.) 2. Close the external manual g as v alve. (See Fig. 7.) 3. T urn of ...

  • Bryant 345MAV - page 7

    7 21 22 NO TE: It will be necessary to remov e 2 scre ws. 4. Remov e air filter from furnace. • AIR FIL TER(S) LOCA TED IN BO TTOM: a. Slide filter retainer sidew ays until it is free of latch. (See Fig. 23.) b . Slide air filter out of furnace. (See Fig. 24.) 23 24 • AIR FIL TER LOCA TED IN SIDE: a. Remov e filter retainer from latch. (See ...

  • Bryant 345MAV - page 8

    8 1. T urn of f gas and electrical supplies to the furnace and remov e the main furnace door . (See Fig. 7, 8, and 9.) 2. Remov e burner enclosure front. (See Fig. 29 or 30.) Inspect the gas b urners and ignitor area for dirt, rust, soot, or scale. 29 30 3. Inspect the comb ustion-air and vent pipes for sags, holes, cracks, or disconnections. 4. Re ...

  • Bryant 345MAV - page 9

    9 A CHECK-UP CHECKLIST Y our furnace represents an important in vestment in your f amily’ s comfort and your home’ s value. T o k eep it performing properly and as a pre ven- tati ve to future problems, hav e a trained service specialist gi ve your furnace a professional check-up annually . The follo wing checklist can be used as a guideline to ...

  • Bryant 345MAV - page 10

    10 MODEL 345MA V DIA GNOSTIC CHAR T (See Fig. 2.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The f ault code is a 2 digit n umber . The first digit is deter mined by the number of short flashes of the light and the second digit is determined by number of long flashes of the light. F AUL T CODE F AUL T COD ...

  • Bryant 345MAV - page 11

    11 ...

  • Bryant 345MAV - page 12

    Cancels: OM05-27 OM05-29 © 1999 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Pr inted in U.S.A. Catalog No. 5334-507 5-99 ...

メーカー Bryant カテゴリー Furnace

Bryant 345MAVのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 345MAVの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant 345MAVの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant 345MAVの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant 345MAVの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant 345MAVのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant 345MAVの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant 345MAVデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant 345MAVを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant 345MAVユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant 345MAVの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant 345MAVの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant 345MAVに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant 345MAVデバイスの基本機能を使うにあたってのヒント。 Bryant 345MAVのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant 345MAVに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant 345MAVのメーカー/サービスへの連絡先に関する情報。

Bryant 345MAVについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant 345MAVの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant 345MAVで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)