    Manual Supplement © 2008-2009 Fluke Corporation . All rights reserv ed. Printed in the U.S .A. Manual Title: Impulse 6000D/7000DP Users Supplement Issue: 3 Print Date: August 2007 Issue Date: 3/09 Revision/Date: 1, 1/08 Page Count: 10 This supplement contai ns information nece ssary to en sure the accuracy of the above manual. This manual is distr ...

  • Fluke 7000DP - page 2

    Impulse 6000D/7000DP Users Manual Supplement 4/08 1 Change #1, 46470, 46697, 47714, 48007, 49680 Replace pages 31 through 35, with the following: Defibrillator Analyzer Specifications Energy Output Measurement Compatible Defibrillator Wa veshapes ................ Lown, Edmark, Trapezoidal, DC Bi -phasic, and AC Pulsed Bi-phasic Note AC Pulsed Bipha ...

  • Fluke 7000DP - page 3

    Manual Supplement Impulse 6000D/700 0DP Users 2 8/08 Accuracy ............................................................. ± 0.1 ms Voltage Range ................................................................. 20 to 5000 V Accuracy ............................................................. ± (1 % of reading + 2 V) Current Range ............ ...

  • Fluke 7000DP - page 4

    Impulse 6000D/7000DP Users Manual Supplement 4/08 3 Scope Output Autorange ........................................................... 2000:1, 400:1 and 80:1: depe ndant on the range Waveform Playback Output ............................................................. BNC Output impedance........................................... 50 Ω Amplitude ...

  • Fluke 7000DP - page 5

    Manual Supplement Impulse 6000D/700 0DP Users 4 3/09 Ventricular Fibrillation ......................................... Coarse and fine Monomorphic Ventricular Tachycardia ............... 120 to 300 (by 5) BPM Polymorphic Ventricular Tachycardia ................. 5 types Asystole .............................................................. Flat l ...

  • Fluke 7000DP - page 6

    Impulse 6000D/7000DP Users Manual Supplement 8/08 5 Normal Sinus waves Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 70 % 100 % 30 % 24 % 48 % 100 % 120 % 112 % 80 % Lead I reference Performance waves and R wave detection Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 100 % 150 % 50 % 100 % 100 % 100 % 100 % 100 % 100 % Normal Sinus waves Lead # I II II ...

  • Fluke 7000DP - page 7

    Manual Supplement Impulse 6000D/700 0DP Users 6 4/08 Sine waves ......................................................... 0.05, 0.5, 5, 10, 40, 50, 60, 10 0, 150, and 200 Hz Pulse ................................................................... 30 and 60 BPM, 60 ms pulse width R-Wave Detection Waveform ........................................... ...

  • Fluke 7000DP - page 8

    Impulse 6000D/7000DP Users Manual Supplement 4/08 7 Accuracy ......................................................... ±(10 % of setting + 0.2 mV) Amplitude of Transvenous Pacer Pulse Simulation signals relative to amplitude setting (in percent) Lead II reference Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 67 % 100 % 33 % 67 % 67 % 67 % 67 % 67 % ...

  • Fluke 7000DP - page 9

    Manual Supplement Impulse 6000D/700 0DP Users 8 4/08 Change #2 On page 12, prior to Analyzing Pacemakers (7000DP only) , add the following section: SCOPE OUTPUT Each time a defibrillator is fired into the An alyzer during an active defibrillator test, a delayed represe ntation of the defibrillator pulse is sent to the Scope Output jack on the rear ...

  • Fluke 7000DP - page 10

    Impulse 6000D/7000DP Users Manual Supplement 4/08 9 Pulse playback +4 V, 1 ms pulse Start of defibrillator pulse playback [1] [1] Pulse playback includes 0.4 ms before th e pulse was detected and theref ore displays any ear ly transitional signals. Use the synchronizing marker pulses to display specific information from the Scope Outpu t signal. To ...

  • Fluke 7000DP - page 11

    Manual Supplement Impulse 6000D/700 0DP Users 10 8/08 Change #3, 48038 On page 38, under Pacemaker Input, change: From: Accuracy …………..±1 % non-inductive (<2 μ H) To: Accuracy……………±2 % non-inductive (<2 μ H) ...

メーカー Fluke カテゴリー CD Player

Fluke 7000DPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 7000DPの取扱説明書
- Flukeの製品カード
- パンフレット
- またはFluke 7000DPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fluke 7000DPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fluke 7000DPの取り付け説明書、サービスマニュアル、簡易説明書、またはFluke 7000DPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fluke 7000DPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fluke 7000DPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFluke 7000DPを使用するのを助ける技術的文書のことです。説明書は通常、全てのFluke 7000DPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Flukeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fluke 7000DPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFluke 7000DPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fluke 7000DPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fluke 7000DPデバイスの基本機能を使うにあたってのヒント。 Fluke 7000DPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fluke 7000DPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFluke 7000DPのメーカー/サービスへの連絡先に関する情報。

Fluke 7000DPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFluke 7000DPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFluke 7000DPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)