Pelco C841M-Aの取扱説明書

16ページ 0.38 mb
ダウンロード

ページに移動 of 16

Summary
  • Pelco C841M-A - page 1

    INST ALLA TION/OPERA TION V A6200 Series Sequential Switcher C841M-A (7/02) ...

  • Pelco C841M-A - page 2

    2 C841M-A (7/02) LIST OF ILLUSTRA TIONS Figure Page 1 Jumper Settings - V A6200 Series ............................................................................................... ..................................................................... 4 2 Fixed Cameras with T erminated Inputs ....................................................... ...

  • Pelco C841M-A - page 3

    C841M-A (7/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X ,6 or 6P enclosure ...

  • Pelco C841M-A - page 4

    4 C841M-A (7/02) INST ALLA TION 1. Remove the cover from the switcher . 2. Set the jumpers as required for your application. Refer to Figure 1 and T able A. 3. Replace the cover . 4. Place the unit on a flat surface or install it in an equipment rack using the appropriate rack-mount kit. 5. Make all equipment connections to the switcher . Refer to ...

  • Pelco C841M-A - page 5

    C841M-A (7/02) 5 Table A. Jumper Settings - VA6200 Series Jumper Position Function JP1 - JP20 A Camera input terminated (75 ohms) B Camera input looping (high impedance) JP23, JP24, JP25, JP26, JP28, JP31 A Camera titles on Monitor 1 B Camera titles on Monitor 2 JP29 or JP32 A P AL video standard B NTSC video standard JP30 or JP33 A Standard charac ...

  • Pelco C841M-A - page 6

    6 C841M-A (7/02) Figure 2. Fixed Cameras with Terminated Inputs Figure 3. Fixed Cameras with Looping Outputs ...

  • Pelco C841M-A - page 7

    C841M-A (7/02) 7 Figure 4. Movable Cameras with Terminated Inputs and Coaxitron Control Figure 5. Movable Cameras with Looping Outputs and Coaxitron Control ...

  • Pelco C841M-A - page 8

    8 C841M-A (7/02) Figure 6. Connector Assembly ...

  • Pelco C841M-A - page 9

    C841M-A (7/02) 9 OPERA TION T o operate the VA6200 Series Switcher: 1. Plug in the power cord. 2. Select the monitor by pushing the MON 1 or MON 2 button. 3. Press a camera button to view video from the corresponding camera. SEQUENCING T o run a sequence: 1. Select a monitor by pushing the MON 1 or MON 2 button. 2. Press the SEQ button. The camera ...

  • Pelco C841M-A - page 10

    10 C841M-A (7/02) DWELL TIME The time between switching from one camera to another is known as the dwell time. The dwell time can be set differently for each camera or it can be set the same (global) for all cameras on a monitor . T o check the dwell time: 1. Select a camera by pressing the button for that camera. 2. Press the camera button again. ...

  • Pelco C841M-A - page 11

    C841M-A (7/02) 11 ALARMS The alarm inputs must be enabled or disabled if you connected alarms on the switcher to them. T o enable or disable alarms: 1. Press the MON 1 button. 2. Press the recessed ALARM switch. The switch toggles the alarm inputs on and off. When the ON LED is lit, the alarm inputs are enabled. When the ON LED is out, the alarm in ...

  • Pelco C841M-A - page 12

    12 C841M-A (7/02) TROUBLESHOOTING PROBLEM SOLUTION No power Check the fuse . Video output quality poor Check jumper settings (Refer to Figure 1, T able A). (Examples: Squiggly video, poor contrast, picture not centered) Locked system or sequencing not working as desired Reset the switcher . There are two types of reset operations: 1. Restart operat ...

  • Pelco C841M-A - page 13

    C841M-A (7/02) 13 SPECIFICA TIONS VIDEO Inputs: T erminating (75 ohms) or looping (high impedance) NTSC and PAL compatible Outputs Monitor 1: 75 ohms Monitor 2: 75 ohms; half duplex (Coaxitron ® compatible). Requires field jumper change Gain: Unity Dwell: Camera dwell independently adjustable from 1 to 60 seconds nominal Frequency Response: 10 MHz ...

  • Pelco C841M-A - page 14

    14 C841M-A (7/02) GENERAL Construction Chassis: Steel, zinc plated Cover: Steel, textured black enamel Panel: Aluminum, with LEXAN ® overlay Dimensions V A6204 Series: 1.75 (H) x 5.50 (W) x 9.25 (D) inches (4.44 x 13.97 x 23.49 cm) V A6208 Series: 1.75 (H) x 8.75 (W) x 11.75 (D) inches (4.44 x 22.23 x 29.84 cm) V A6212 Series: 1.75 (H) x 14.25 (W) ...

  • Pelco C841M-A - page 15

    C841M-A (7/02) 15 REVISION HISTORY Manual # Date Comments C841M 12/99 Original version. C841M-A 7/02 Updated manual to new format. Removed reference to alarm breakout panel. PRODUCT WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco. © Copyright 2002, Pelco. En ...

  • Pelco C841M-A - page 16

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ...

メーカー Pelco カテゴリー Switch

Pelco C841M-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C841M-Aの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C841M-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C841M-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C841M-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C841M-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C841M-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C841M-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C841M-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C841M-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C841M-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C841M-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C841M-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C841M-Aデバイスの基本機能を使うにあたってのヒント。 Pelco C841M-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C841M-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C841M-Aのメーカー/サービスへの連絡先に関する情報。

Pelco C841M-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C841M-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C841M-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)