CDA EVX140の取扱説明書

28ページ 関係なし
ダウンロード

ページに移動 of 28

Summary
  • CDA EVX140 - page 1

    Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu evx100 / evx140 Extractor Manual for Installation, Use and Maintenance ...

  • CDA EVX140 - page 2

    2 Important The CD A Group L td cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CD A reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment. This appliance is no ...

  • CDA EVX140 - page 3

    3 IMPORT ANT INFORMA TION FOR CORRECT DISPOSAL OF THE PRODUCT IN A CCORD ANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services. Disposing of a household appliance separately avoids possible negative conse ...

  • CDA EVX140 - page 4

    4 Please note: • Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system. • Do not vent the extractor into an attic or loft space. • Only house the extractor in rooms with adequate ventilation. R emember that the extractor is powerful and whatever air is extracted needs to ...

  • CDA EVX140 - page 5

    5 Using Y our Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for appro ximately 15 minutes after the end of cooking. T o switch on the extractor and set the speed level - T ouch key “ A ” or press button 1 on the remote. The appliance will switch on at the last speed lev ...

  • CDA EVX140 - page 6

    6 remote control. Whilst the intensive function is active “HI” appears on the centre of the display and the bottom right hand dot flashes once a second. - T o cancel the intensive function, touch key “D” or button 5 again and the extractor will return to the previous speed level. The extractor lights - T o switch the lights on and o , p ...

  • CDA EVX140 - page 7

    7 - T o activate the clean air function, touch key “E” when the appliance is either on or o . When the clean air function is running, “24” will show on the display and a dot will flash in the lower right hand corner of the display when the motor is running. - T o cancel the clean air function, touch any key ex cept the light key . Care ...

  • CDA EVX140 - page 8

    8 T o reset the filter alarm, press button “E” for appro ximately 3 seconds when the extractor is switched o . T o remove the grease filters follow the steps below: 1. Open the stainless steel cover panels by pulling them down and outwards on either side. They will remain located in their hinges. 2. Pull open the handle on each grease fil ...

  • CDA EVX140 - page 9

    9 should remove and replace the charcoal filters. T o attach a new charcoal filter , first open the cover panels and remove the grease filters as described above. Then oer up the charcoal filter to the side of the motor as shown in figure 3 and turn it clockwise until it locks into place. R epeat with the other charcoal filter on the othe ...

  • CDA EVX140 - page 10

    10 R emove the old bulb from the holder . Fit the new bulb, taking care not to touch the glass of the bulb. T ake care to ensure any tools used do not damage the extractor body . Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights. The main extractor light is designed for use during cooking only . The ambient l ...

  • CDA EVX140 - page 11

    11 Installation Positioning the vent outlet: The motor unit can be turned to position the outlet to any of the four sides. 1. Open the decorative cover panel and remove the two grease filters (fig. 5). The decorative cover can be removed, if required, to make the installation easier . T o do this, simply remove the cover fixing screws using an a ...

  • CDA EVX140 - page 12

    12 Installation Installing the extractor: The extractor can be mounted directly into the ceiling, where space between the ceiling and joists permits, or it can be built into a false ceiling. T o install the product, proceed as follows: 1. Mark the ceiling or false ceiling, as appropriate, with centre point of the hob to start the positioning of the ...

  • CDA EVX140 - page 13

    13 4. Drill the dierent holes required for the mounting, as below , using a drill bit suitable for the ceiling material: • The 150mm diameter vent outlet when the ducting will run through the ceiling. • The mains supply chord (10mm minimum). • The four fixing holes for the  10mm nuts and bolts. 5. When the extractor is to be mounted in ...

  • CDA EVX140 - page 14

    14 ceiling, use a sleeve to prevent damage to the plasterboard when the four 10mm nuts and bolts are being tightened. When the ceiling is concrete, use eight diameter symbol 10mm steel rawl bolts. Do not use plastic rawl plugs 6. The motor body incorporates top fixing mounts that can be adjusted by up to 20mm depending on the installation, as show ...

  • CDA EVX140 - page 15

    15 Installation Into a False Ceiling: (T wo persons required) 1. Open the decorative cover panel and remove the two grease filters. 2. R emove the light panels by removing the three screws securing each panel first. Lift the panel and pull towards the centre of the extractor to expose the connections. Carefully disconnect the light connections an ...

  • CDA EVX140 - page 16

    16 fig. 15 3. The extractor is intended to be secured to the ceiling using the four adjustable spring-loaded clips; these are shown in the image below: 4. Before securing the extractor to the ceiling, prepare and connect the ducting as described in the ducting section following the installation information and ensure that the mains electrical supp ...

  • CDA EVX140 - page 17

    17 the adjustment screw to secure the extractor firmly in position Note: When fixing to an 18mm MDF false ceiling, four 2mm spacers have been provided to make the mounts 20mm thick (minimum). If the extractor needs to be removed after installation for any reason, the fixing clips should be slackened and then can be accessed by removing the foil ...

  • CDA EVX140 - page 18

    18 Ducting: The extractor can be used as a recirculation device or as a extraction device, depending on your installation. The hood is more eective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150mm (6 Inches), rigid circular ...

  • CDA EVX140 - page 19

    19 R e-Circulation: An internal air vent is required, as shown below . This ensures that the air is placed back in the kitchen after it has been filtered Fit the charcoal filters to the body of the motor as shown in the maintenance section of the manual. Extraction: The extractor is provided with a non-return butterfly valve which should be fit ...

  • CDA EVX140 - page 20

    20 Adjusting the P osition of the Decorative Cover P anel: The decorative panel can be finely adjusted by moving the positions of the cover hinges, as shown here. Use a suitable allen key or small hex driver (3mm) to slacken the cover adjusting screws before sliding the cover into the correct position. When done, re-tighten the fixing screws. fi ...

  • CDA EVX140 - page 21

    21 T ypical Installation Examples: ...

  • CDA EVX140 - page 22

    22 Changing the Light IMPORT ANT : DO NO T PERFORM MAINTENANCE OR A TTEMPT T O CLEAN THE EXTRA CTOR WITHOUT FIRS T SWITCHING OFF THE ELECTRICITY SUPPL Y . DO NO T CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HO T . ALL OW T O COOL BEFORE REMOVING. 1. Unfasten the sliding brackets on either side of the cover panel and the cover ...

  • CDA EVX140 - page 23

    23 Synchronising the remote control with the extractor When the extractor is o , press and hold button “B” , and then switch the extractor on. After five seconds release button “B” and the display will light up in sections. Then press button “E” . “T C” will flash twice to confirm the remote is synchronised. “T C” will fl ...

  • CDA EVX140 - page 24

    24 Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSE SPUR OUTLET AND PRO TECTED BY A 3A FUSE. W arning! This appliance must be earthed W e recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E. ...

  • CDA EVX140 - page 25

    25 • The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red. Note: Use a 3A Fuse Assembly and electrical connection should be carried out by specialised personnel. When installing this product we recommend you seek the help of another individual. The mains isolation switch should be readily accessible ...

  • CDA EVX140 - page 26

    26 Electrical Information Mains electrical voltage: 230 – 240V ac. T otal rated power consumption evx100 / evx140: 410W . T roubleshooting Please note: Y our extractor is equipped with a motor protection device that will switch o the motor to prevent damage from overheating. This may happen during cooking when most or all of the zones/ burners ...

  • CDA EVX140 - page 27

    27 Attribute Symbol Value Units Model Identification evx100/140 Annual Energy Consumption AEC Hood 201.7 kWh Time increase factor f 1.0 Fluid Dynamic Efficiency FDE Hood 18.8 (C) Energy Efficiency Index EEI Hood 98.1 Measured airflow at Best Efficiency Point Q BEP 394.0 m 3 /h Measured Pressure at Best Efficiency Point P BEP 254.0 Pa Maximum airflo ...

  • CDA EVX140 - page 28

    Please contact our Customer Care Department for Service on the details below . Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www. cda.eu ...

メーカー CDA カテゴリー Exhaust hood

CDA EVX140のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EVX140の取扱説明書
- CDAの製品カード
- パンフレット
- またはCDA EVX140の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、CDA EVX140の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、CDA EVX140の取り付け説明書、サービスマニュアル、簡易説明書、またはCDA EVX140のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、CDA EVX140の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

CDA EVX140デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCDA EVX140を使用するのを助ける技術的文書のことです。説明書は通常、全てのCDA EVX140ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

CDAの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. CDA EVX140の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCDA EVX140の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。CDA EVX140に関してこのドキュメントで見つけることができる全てのヒントの目次
3. CDA EVX140デバイスの基本機能を使うにあたってのヒント。 CDA EVX140のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。CDA EVX140に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCDA EVX140のメーカー/サービスへの連絡先に関する情報。

CDA EVX140についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCDA EVX140の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCDA EVX140で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください