-
ADDER Adder TS4 - page 1
www .adder .com 4 3 2 1 ADDER Adder TS4 Four -port keyboard and mouse switch ...
-
ADDER Adder TS4 - page 2
1 SECT 1 Contents W elcome Introduction ................................................................................. 2 Automatic switching between systems ................. ...
-
ADDER Adder TS4 - page 3
2 Automatic switching between systems When used with Synchrony softwar e, the Adder TS4 allows automatic switching between the connected systems and screens. The switching betwe ...
-
ADDER Adder TS4 - page 4
3 Ho w does Synchrony work? Synchrony is a small softwar e utility that runs on each of your computer systems and continually tracks the current mouse cursor position. One syste ...
-
ADDER Adder TS4 - page 5
4 Optional power supply (required only when long cables are used) plus country-specific mains cable Adder P/N: PSU-IEC-5VDC-2A PS/2-style keyboard/mouse cable, 2 metres (two re ...
-
ADDER Adder TS4 - page 6
5 I nstallation Locations Please consider the following important points when planning the position of the Adder TS4 unit: • Situate the Adder TS4 unit close to the systems to ...
-
ADDER Adder TS4 - page 7
6 Making connections Connections to the Adder TS4 unit do not need to follow the precise or der given in this user guide, although if one or more systems must be hot-plugged , c ...
-
ADDER Adder TS4 - page 8
7 Keyboar d and mouse connections T o connect a keyboard and mouse 1 At the rear panel of the Adder TS4 unit, attach the connector from the keyboard to the purple socket that is ...
-
ADDER Adder TS4 - page 9
8 Installing Synchr ony This section covers the connections, switch setting and software installation procedur es required to use the Synchr ony application with the Adder TS4 u ...
-
ADDER Adder TS4 - page 10
9 Configuration for Synchrony T o correctly configure Synchrony , you need to install a copy on each system, configure one as the server and the r est as clients. Y ou then n ...
-
ADDER Adder TS4 - page 11
10 6 Beneath the Screens field, click the ‘+’ button to display the Add Screen dialog so that you can add a new screen (computer system): 7 In the ‘Screen Name’ field, ...
-
ADDER Adder TS4 - page 12
11 PC1 PC2 PC3 PC4 (PRIMARY) 0 to 100 % of the left of PC2 goes to 0 to 100 % of PC1-Primary 0 to 100 % of the bottom of PC2 goes to 0 to 100 % of PC4 0 to 100 % of the right of ...
-
ADDER Adder TS4 - page 13
12 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON Configuration switch settings The underside of the TS4 unit features a block of eight switches which ar e used to configure various fu ...
-
ADDER Adder TS4 - page 14
13 Hot plugging and mouse r estoration It is strongly r ecommended that you switch off a host system before attempting to connect it to the Adder TS4. However , if this is not p ...
-
ADDER Adder TS4 - page 15
14 SECT 4 Operation In operation, the Adder TS4 allows you to quickly switch between up to four systems. One system can be accessed at a time, whereupon the common keyboard and ...
-
ADDER Adder TS4 - page 16
15 Configuration options The Adder TS4 provides numer ous configuration options to ensure that it best suits your circumstances and the tasks carried out by the connected syst ...
-
ADDER Adder TS4 - page 17
16 Mouse button switching modes Y ou can use a three button mouse to switch between systems. However , when used in this way , the action of the middle mouse button or scroll wh ...
-
ADDER Adder TS4 - page 18
17 U pgrading Like all Adder products, the internal software (firmwar e) of the TS4 is designed to be easily upgraded in order to take advantage of a continual pr ocess of impr ...
-
ADDER Adder TS4 - page 19
18 F ur ther infor mation T roubleshooting If you experience problems when installing or using the Adder TS4, please check through this section for a possible solution. If your ...
-
ADDER Adder TS4 - page 20
19 Safety infor mation • For use in dry , oil free indoor envir onments only . • Not suitable for use in hazardous or explosive envir onments or next to highly flammable ma ...
-
ADDER Adder TS4 - page 21
20 Emissions and Immunity All interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission r egulations and en ...
-
ADDER Adder TS4 - page 22
21 www .ctxd.com Documentation by: © 2008 Adder T echnology Limited All trademarks are acknowledged. Release 1.1c November 2008 Part No. ADD0064 Adder T echnology Limited, T ec ...
ADDER Adder TS4についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもADDER Adder TS4の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがADDER Adder TS4で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。