    BLOOMFIELD INDUST RIES 2 ERIK CIRCLE , P . O. Box 280 V erdi , NV 8943 9 Cust omer Servi ce ( 775) 345 -0444 Ext .502 fax: (775) 345-0569 www .well sbl oomfi eld. com p/n 75804 Rev. (-) M611 011802 cps 611 OWNERS M A NUAL For MODUL A R BREWING SYSTEMS MODELS POUR OVER AUTOMATIC AUTOMATIC UNITS UNITS UNITS WITH FAUCET 8542 8541 8540 8543 8573 8572 8 ...

  • Bloomfield 8571 - page 2

    NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DAMAGE: Be certain that any vi ...

  • Bloomfield 8571 - page 3

    TABLE OF CONTENTS Thank You for purcha sing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life. This ma nual contains the information needed to properly install this appliance, and ...

  • Bloomfield 8571 - page 4

    FEATURES AND OPERATING CONTROLS Fig. 1 Fea tures & Operating Controls 2 ...

  • Bloomfield 8571 - page 5

    PRECAUTIONS AND GENERAL INFORMATION WA RNI NG: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WA RNI NG: Injury Hazard All installation procedu ...

  • Bloomfield 8571 - page 6

    INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST A LLA TIO N REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR COMPONENT NAMES/NUMBERS Unpack the unit. Inspec t all components fo r completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket (#33) and Spray Dis ...

  • Bloomfield 8571 - page 7

    INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plumbin g codes and ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause de ...

  • Bloomfield 8571 - page 8

    OPERATION Fig. 4 Brewer Operation Diagram A. STAR T-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew ga sket are properly installed in the brew head. ♦ Be sure the water supply is properly connecte d and the water supply valve is turned ON . ♦ Be sure the W ATER TANK IS ...

  • Bloomfield 8571 - page 9

    OPERAT ION (continu ed) WATER HEATER Water temperat ure is sensed by a thermobulb insert ed into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating elemen t. The setpoint temperature is adjustable at the therm ostat. The elem ent is prot ected fr om over- temperature by a hi -limit thermostat. ...

  • Bloomfield 8571 - page 10

    BREWING COFFEE CA UTI ON: Burn Hazard Exposed surfaces of the brewer, brew chamber and decanter m ay be HOT to the touch, and can cause serious burns. CA UTIO N: Burn Hazard To avoid splashing or over- flowing hot liquids, ALWAYS place an empty decanter under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns ...

  • Bloomfield 8571 - page 11

    CLEANING INSTRUC TIONS PROCEDURE: Clean Coffee Brewe r PRECAUTIONS: Disconnect bre w er fro m electric power. Allow brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean Sof t Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power. Allo w brewer to cool before cleaning. 2. Remove and empty de ca nters. 3. Remove and empty ...

  • Bloomfield 8571 - page 12

    10 TROUBLESHOOTING SUGGESTI ONS SUGGESTED REMEDY Check po wer supply cord Check / reset circuit breaker Set for desired temperature Allow to cool Reset hi-limit (8786, 8788) Examin e w iring & connec tors, thermostat and heating element Repair/replace as needed Be sure to add sufficient water Increase wat er amount Adjust am ount of ground s Ad ...

  • Bloomfield 8571 - page 13

    SERVICING INSTRUCTIONS ACCESS PANELS Each warmer plate has a center stud which screws into a bracket. Remove warmer plates by turning counter-clockwise. Solenoid door is held by two screws and a retaining lip. Front Panel (In-Line Models) and To p / Rear Panel (3-Station Models): a. Remove warmer plate b y turning counter-clockwise until it unscre ...

  • Bloomfield 8571 - page 14

    SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place an empty decanter under brew chamber. Energize brewer and pour o ne decanter (6 4 oz.) of cold ...

  • Bloomfield 8571 - page 15

    SERVICING INSTRUCTIONS ( continued) IMPORTA NT: Water pressure must be betwee n 20 p.s.i and 90 p.s.i. flowing pressure. If wate r pressure e xceeds this value, or if water pressure varies g reatly, a pressu re regulator must be installed in the w ater s upply line. IMPORTA NT: Before se tting assembly into tank, make sure tank lid gasket is proper ...

  • Bloomfield 8571 - page 16

    SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer d rips continuously from brew head. Unplug power cord or turn circuit breaker OFF . Turn OFF and disconnect w ater supply from brewer inlet fitting. A. (OLD-STYLE) Remove hex nut holding inlet fitting into back of brewer. Remove t ...

  • Bloomfield 8571 - page 17

    SERVICING INSTRUCTI ONS (continued) IMPORTA NT: When replacing water faucet coil, also rep lace seal gaskets. NOTE : Any abrasion or roughness on the flat end of the seat cup will re quire replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem. Install a ne w seat cu p, making sure the k nob on t he stem is fully ...

  • Bloomfield 8571 - page 18

    CA UTION - CH EMICA L BU RN HA Z A RD Deliming chem icals are caustic. W ear appropriate pr otective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rmed by qualified and ex- perienced service personnel. IMPORT ANT: DO NOT spill, splash or pour water or deliming s ...

  • Bloomfield 8571 - page 19

    7. Set the tank back into the bre wer. Reassemble the tank lid to the water tank. Make sure the gask et is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and ther mostat. Reinstall the hi-limit thermostat (if removed). For brew ers with hot water faucet, reassemble fa ucet piping. Verify that all inter ...

  • Bloomfield 8571 - page 20

    EXPLODED VIEW & PARTS LIST CABINET & RELATED COMPONENTS 18 ...

  • Bloomfield 8571 - page 21

    EXPLODED VIEW & PARTS LIST (continued) 19 ITEM P A RT NO. DESCR IPTION USED ON 1 8700-16 W armer Cov er Plate, Black All 8875- 149 20 8543-23 T i nnerman Nut , #8 (not shown ) All 2 3 8 543 -6 9 H ey co B us hi ng Al l 33 854 3-42 S pr ay Head Gaske t All 34 827 27 S pray Dis k All 34a 854 3-45 S pr ay Head Retai ner All 35 857 2-34 Door , Sole ...

  • Bloomfield 8571 - page 22

    EXPLODED VIEW & PARTS LIST (continued) HOT WATER TANK ASSEMBLY 20 ITEM P ART NO. DESCRI PTION USED ON 13 8043-5 Hol d Down S trap All 50 8512- 51 Therm ostat Al l 52 8512-41 Seal Washer All 54 8043-12 T an k Cover Gasket All 56 8043-30 Seal G asket All 58 8540-6 Hot Water Coil 8540, 857 2, 8574 59 8043-8 Inl et Elbow All 60 8043-15 Vent Tube Al ...

  • Bloomfield 8571 - page 23

    ELECTRICAL COMPONENTS EXPLODED VIEW & PARTS LIST (continued) 21 2 8572-18 W armer Element, 120V 100W All 30 6710-23 W ar mer ON /OFF Switc h All 31 8572-24 B REW Sw itch, push-button 8572, 8573 , 8574 8707-55 B REW SWI TCH , momen tary rock er 8540, 8541 32 8718-31 R EADY TO BREW Indicator Light All 36 6407-15 C ord & Cap As semb ly , NEMA ...

  • Bloomfield 8571 - page 24

    EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS 22 ITEM P ART NO. DESCRIPTION USED ON 60 8043-15 V ent T ube All 61l 8 8540-3 Faucet Outlet T ub e As sembly 8540, 8572 & 8574 9 8540- 4 Formed Inlet T ube Assembly 8540, 8572 & 8574 10 8551-30 1/4“ Male Flare x 1/ 8 ” FPT 8540, 8572 & 8574 1 1 8514-26 N eedle V ...

  • Bloomfield 8571 - page 25

    WIRING DIAGRAMS 23 ...

  • Bloomfield 8571 - page 26

    WIRING DIAGRAM 24 ...

  • Bloomfield 8571 - page 27

    WIRING DIAGRAM (continued) 25 ...

  • Bloomfield 8571 - page 28

    Bloo mfield In dustri es, Inc. Divisi on of C arrier Refrig eratio n Blo om fiel d In dust ri es Canad a Li mi ted Divisi on of C arrier Refrig eratio n PO. Box 280 V erd i, NV . 894 39 T elephone ( 775)345-0 444 Fax (888)492-27 83 Service: (888)492-2782 website: ww w .wellsbloomfield.com 5850 Keaton Cr esent Mississauga, Ont ario , Canada L5R 3K 2 ...

メーカー Bloomfield カテゴリー Coffeemaker

Bloomfield 8571のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 8571の取扱説明書
- Bloomfieldの製品カード
- パンフレット
- またはBloomfield 8571の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bloomfield 8571の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bloomfield 8571の取り付け説明書、サービスマニュアル、簡易説明書、またはBloomfield 8571のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bloomfield 8571の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bloomfield 8571デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBloomfield 8571を使用するのを助ける技術的文書のことです。説明書は通常、全てのBloomfield 8571ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bloomfieldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bloomfield 8571の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBloomfield 8571の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bloomfield 8571に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bloomfield 8571デバイスの基本機能を使うにあたってのヒント。 Bloomfield 8571のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bloomfield 8571に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBloomfield 8571のメーカー/サービスへの連絡先に関する情報。

Bloomfield 8571についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBloomfield 8571の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBloomfield 8571で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください