    Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER ALSO DESIGN- CERTIFIED AS A VENTED DECORATIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL 18", 24" and 30" Variable Manually-Controlled Models Patent Pending Heat Majic™ Models FVF18P , FVF24P , and FVF30P WARNING: If the informati ...

  • FMI FVF24P - page 2

    2 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! WARNING ICON G 001 WARNINGS IMPORTANT: Read this owner ’ s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, ...

  • FMI FVF24P - page 3

    3 105192 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54* . *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymar ...

  • FMI FVF24P - page 4

    4 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUATE VENTILATION The following a r e excerpts from Na- tional Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combus- tion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T igh ...

  • FMI FVF24P - page 5

    5 105192 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with d ...

  • FMI FVF24P - page 6

    6 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within ...

  • FMI FVF24P - page 7

    7 105192 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear* Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21" 30" 17" 14" 34" 24" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If y ...

  • FMI FVF24P - page 8

    8 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER INST ALLA TION Continued Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace Heat Resistant Material (A) Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using a Mantel. If not using a mantel, follow the information below. Y ...

  • FMI FVF24P - page 9

    9 105192 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non- Combustible Material 8" Min. 12" 15" 18" All minimum distances are in inches 20" 2 1 /2 " 6" 8" 10" 12" Distances to Underside of Mantel Hood (HDABK, HDABR) Top of Fireplace Opening Underside of Mantel Shelf ...

  • FMI FVF24P - page 10

    10 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER INST ALLA TION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non combustible material. You may use this heater as a vented product. There ar ...

  • FMI FVF24P - page 11

    11 105192 OWNER’S MANUAL Masonry Screw Figure 12 - Attaching Base Assembly to Fireplace Floor Bracket with Screw Holes INST ALLA TION Continued Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Fitting Continued Installation Items Needed • hardware package (provide ...

  • FMI FVF24P - page 12

    12 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER INST ALLA TION Continued Tee Joint Pipe Nipple Cap 3" Minimum Sediment Trap Gas Regulator From External Regulator (11" W.C.** to 14" W.C. Pressure) CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap Approved Flexible Gas Hose (if allowed by local codes) Figure 14 - Gas C ...

  • FMI FVF24P - page 13

    13 105192 OWNER’S MANUAL ON POSITION OFF POSITION INST ALLA TION Continued Figure 15 - Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Figure 16 - Checking Gas Joints Control Valve Location Propane/LP Supply Tank Equipment Shutoff Valve Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconn ...

  • FMI FVF24P - page 14

    14 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS It is very important to install the logs exactly as instructed. Do not ...

  • FMI FVF24P - page 15

    15 105192 OWNER’S MANUAL 1. STOP! Read the safety inf ormation, column 1. 2. Make sure equipment shutoff v alve is fully open. 3. Press in and tur n control knob clock- wise Clockwise to the OFF position. Figure 20 - Pilot OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or ...

  • FMI FVF24P - page 16

    16 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pat- tern. Figure 22 shows an incorrect pilot flame pattern. ( Note: Appearance of pilot assembly may vary by model.) The incor- rect pilot flame is not touching the t ...

  • FMI FVF24P - page 17

    17 105192 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor c ...

  • FMI FVF24P - page 18

    18 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit White powder residue forming within burner box or on adj ...

  • FMI FVF24P - page 19

    19 105192 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If you canno ...

  • FMI FVF24P - page 20

    20 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need m ...

  • FMI FVF24P - page 21

    21 105192 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Technical Service D ...

  • FMI FVF24P - page 22

    22 105192 UNVENTED PROP ANE/LP GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN HEAT MAJIC ™ FVF18P FVF24P FVF30P ODS Pilot 4 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 2 18 13 19 17 20 18 3 1 ...

  • FMI FVF24P - page 23

    23 105192 OWNER’S MANUAL P AR TS LIST FVF18P FVF24P FVF30P This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. KEY PART NUMBER FOR NO. FVF18P FVF24P FVF30P DESCRIPTION QTY 1 105186-01 105186-02 105186-03 One-Piece Log Set 1 2 098276-01 098 ...

  • FMI FVF24P - page 24

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased 105192-0 ...

メーカー FMI カテゴリー Gas Heater

FMI FVF24Pのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FVF24Pの取扱説明書
- FMIの製品カード
- パンフレット
- またはFMI FVF24Pの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、FMI FVF24Pの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、FMI FVF24Pの取り付け説明書、サービスマニュアル、簡易説明書、またはFMI FVF24Pのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、FMI FVF24Pの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

FMI FVF24Pデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFMI FVF24Pを使用するのを助ける技術的文書のことです。説明書は通常、全てのFMI FVF24Pユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

FMIの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. FMI FVF24Pの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFMI FVF24Pの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。FMI FVF24Pに関してこのドキュメントで見つけることができる全てのヒントの目次
3. FMI FVF24Pデバイスの基本機能を使うにあたってのヒント。 FMI FVF24Pのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。FMI FVF24Pに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFMI FVF24Pのメーカー/サービスへの連絡先に関する情報。

FMI FVF24Pについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFMI FVF24Pの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFMI FVF24Pで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)