    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © 2008 Zephyr Corporation W illow AK8800AS AK8800AG READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...

  • Zephyr AK8800AS - page 2

    www .zephyronline.com ...

  • Zephyr AK8800AS - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK8800AS - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY T O PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK8800AS - page 5

    Important Safety Notice 3 CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair , fi ngers and loose clothing ...

  • Zephyr AK8800AS - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK8800AS AND AK8800AG P ARTS SUPPLIED 1 - 316S High quality stainless steel Power Pack (AK8800AS) or 1 - Gray powder coated Power Pack (AK8800AG) 2 - Baf fl e fi lters 2 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 8” round adapter 1 - Hardware package HARDW ...

  • Zephyr AK8800AS - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...

  • Zephyr AK8800AS - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 8” round ducting must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Also use calculation (on page 5) to compute total available duct run when using e ...

  • Zephyr AK8800AS - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK8800AS - page 10

    8 www .zephyronline.com Installation – Speci fi cations top side front C L 11 7/16 ” 13/16” 2 5/8 ” 14 11 / 1 6 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 1 5/16 ” 1 1/2 ” C L elec. k/o 5” 7 3/4 ” 4 3/8 ” 1 1/2 ” 1 3/4 ” elec k/o 6 1/2 ” 15 13/16 ” 14 11 / 1 6 ” 11 7/16 ” 11 7/16 ” 4 ...

  • Zephyr AK8800AS - page 11

    9 ELECTRICAL W ARNING All Electrical work must be performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK8800AS - page 12

    10 www .zephyronline.com Installation – Installing the Power Pack Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. (FIG 3) 2. Install optional AK088xAS Stainless Steel Liner under custom hood opening. Review manual included with lin ...

  • Zephyr AK8800AS - page 13

    11 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Controls – Rocker Switch Controls ...

  • Zephyr AK8800AS - page 14

    12 www .zephyronline.com Maintenance – Cleaning and Installing Filters SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier s ...

  • Zephyr AK8800AS - page 15

    13 Maintenance – Lights REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, ...

  • Zephyr AK8800AS - page 16

    14 www .zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR WILLOW Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power con ...

  • Zephyr AK8800AS - page 17

    List of Parts and Accessories 15 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210010 Optional Accessories Liner , 36” AK0886AS Liner , 42” AK0882AS Liner , 48” AK0888AS Liner , 54” AK0884AS Liner , 60” AK0880AS T o order parts, visit us online at http://store.zephyronline.com o ...

メーカー Zephyr カテゴリー Ventilation Hood

Zephyr AK8800ASのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AK8800ASの取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr AK8800ASの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr AK8800ASの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr AK8800ASの取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr AK8800ASのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr AK8800ASの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr AK8800ASデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr AK8800ASを使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr AK8800ASユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr AK8800ASの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr AK8800ASの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr AK8800ASに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr AK8800ASデバイスの基本機能を使うにあたってのヒント。 Zephyr AK8800ASのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr AK8800ASに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr AK8800ASのメーカー/サービスへの連絡先に関する情報。

Zephyr AK8800ASについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr AK8800ASの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr AK8800ASで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)