Miller Electric IHの取扱説明書

76ページ 1.81 mb
ダウンロード

ページに移動 of 76

Summary
  • Miller Electric IH - page 1

    IH/TS Processes Description OM-203 185F 2005 − 09 Induction Heating Single Induction Heating Power Source T emperature Control/Recorder Visit our website at www.MillerWelds.com File: Induction Heating ...

  • Miller Electric IH - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .Mille ...

  • Miller Electric IH - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Induction Heating Hazards 1 . . . . . ...

  • Miller Electric IH - page 4

    T ABLE OF CONTENTS 6-3-5. Recovering From An Interruption 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3-6. V iewing Data In Review Software 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3-6-1. Installing Review Softw ...

  • Miller Electric IH - page 5

    OM-203 185 Page 1 SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage safety_ihom 5/05 Means Warning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special s ...

  • Miller Electric IH - page 6

    OM-203 185 Page 2 FIRE OR EXPLOSION hazard. D Do not overheat parts and adhesive. D W atch for fire; keep extinguisher nearby . D Keep flammables away from work area. D Do not locate unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not operate unit in explosive atmosphere. INDUCTION HE A TING can cause burns ...

  • Miller Electric IH - page 7

    OM-203 185 Page 3 1-6. EMF Information Considerations About Induction Heating And The Effects Of Low Fre- quency Electric And Magnetic Fields Th e following is a quotation from the General Conclusions Section of the U.S. Congress, Office of T echnology Assessment, Biological Effects of Power Frequency Electric & Magnetic Fields − Background P ...

  • Miller Electric IH - page 8

    OM-203 185 Page 4 SECTION 2 − MESURES DE SECURITE POUR LE CHAUFF AGE P AR INDUCTION ihom_fre 8/03 PRENDRE LES MESURES NECESSAIRES POUR EVITER LES RISQUES DE BLESSURES GRA VES, VOIRE MORTELLES. TENIR LES ENF ANTS A DIST ANCE. LES PORTEURS D’UN STIMULA TEUR CARDIAQUE DOIVENT PREALABLEMENT CONSUL TER LEUR MEDECIN. Pendant les opérations de chauf ...

  • Miller Electric IH - page 9

    OM-203 185 Page 5 DES FUMEES ET DES GAZ peuvent être dangereux pour votre santé. Le chauf fage à induction génère des fumées et des gaz. Leur inhalation peut être dangereuse pour votre santé. 1. Eloigner la tête des fumées. Ne pas respirer les fumées. 2. A l’interieur , ventiler la zone et/ou utiliser un extracteur pour l’évacuation ...

  • Miller Electric IH - page 10

    OM-203 185 Page 6 2-2. Informations concernant les champs électro-magnétiques (Information EMF) Considérations relatives au chauffage à induction et aux ef fets des champs électriques et magnétiques basse fréquence. Le texte suivant est extrait des conclusions générales Département du Congrès U.S., Office of T echnology Assessment, Effet ...

  • Miller Electric IH - page 11

    OM-203 185 Page 7 SECTION 3 − INTRODUCTION The Induction Heating T emperature Station (IH/TS) is designed to be used with Induction Heating Systems for pre-heat and post-heat (stress relieving) applications. The station is built in two dif ferent configurations; as a controller only or as a controller with a digital recorder . The controller in t ...

  • Miller Electric IH - page 12

    OM-203 185 Page 8 SECTION 4 − INST ALLA TION 4-1. Specifications Specification Description Overall Dimensions Height: 10 in (254 mm); Width: 14-1/2 in (368 mm); Depth: 16 in (406 mm) W eight Net: IH/TS (no recorder) 13.1 lb (5.9 kg); IH/TS (digital recorder) 21.1 lb (9.6 kg) T ype Of Input Power 24 V olts DC, 1 15 V olts AC Memory Capacity One Pr ...

  • Miller Electric IH - page 13

    OM-203 185 Page 9 4-3. Connecting T o Power Source T ur n Off power source. 1. IH/TS 2. Interconnecting Cord 3. 14-Socket Plug 4. 14-Pin Plug Obtain cord with 14-socket plug on one end and 14-pin plug on other end. 5. Keyway 6. Remote 14 Receptacle RC1 (See Section 4-4) T o connect cord to a receptacle, align keyway , insert plug, and tighten threa ...

  • Miller Electric IH - page 14

    OM-203 185 Page 10 4-5. Connecting 25kW System Cords And Cables Connect the power output cable and coolant lines as shown. Connect 1 10-volt power cable as shown. Plug the 1 10-volt cooler power cord into th e duplex at the rear of the power source cart. O n the 25kW system, the cooler must be plugged into the right side duplex. This is identified ...

  • Miller Electric IH - page 15

    OM-203 185 Page 1 1 4-6. Connecting 5kW System Cords And Cables Connect the power output cable and coolant lines as shown. Connect 1 10-volt power cable as shown. Plug the 1 10-volt cooler power cord into th e duplex at the rear of the power source cart. The IH/TS Control is plugged in the left side duplex. Do not use these duplex connections for o ...

  • Miller Electric IH - page 16

    OM-203 185 Page 12 4-7. Connecting External Device The IH/TS must have (as a minimum) one thermocouple connected to receptacle TC1. If multiple thermocouples are desired, either use individual thermocouple plugs or the thermocouple extension cable. T o connect thermocouples to the control, proceed as follows: T urn Off power source. 1. T emperature ...

  • Miller Electric IH - page 17

    OM-203 185 Page 13 SECTION 5 − COMPONENTS AND CONTROLS 5-1. IH/TS Front Panel Y Keep all panels, doors, and covers closed and secure during programming. 1. T emperature Controller 2. Parameter Display Screen 3. Heat On Pilot Light 4. Fault/ Limit Light 5. Run Button 6. Hold Button 7. Stop Button 8. Recorder (If Equipped) 1 2 3 4 5 6 7 8 Ref. 803 ...

  • Miller Electric IH - page 18

    OM-203 185 Page 14 5-2. IH/TS Rear Panel Y Keep all panels, doors, and covers closed and secure during programming. 1. Thermocouple Connectors 2. On/Of f Power Switch 3. 1 15 V AC Power Cord 4. 14-Pin Receptacle 5. Coolant Flow Switch “IN” Fitting 6. Coolant Flow Switch “OUT” Fitting 7. Power Source Select Switch 8. Network Connection Ref. ...

  • Miller Electric IH - page 19

    OM-203 185 Page 15 5-3. Controller Y Keep all panels, doors, and covers closed and secure during programming. 1. Digital Display 2. Page Forward Button 3. Scroll Button 4. Down Button 5. Up Button 6. Actual T emperature 7. Setpoint T emperature 8. Auto/Man Button (Disabled) 9. Run/Hold Button (Disabled) 1 2 AUT O MAN RUN HOLD B Y 34 5 200.0 200.0 O ...

  • Miller Electric IH - page 20

    OM-203 185 Page 16 SECTION 6 − SETUP AND OPERA TION 6-1. Safety Equipment W ear the following during operation: 1. Dr y , Insulating Gloves 2. Safety Glasses With Side Shields DO NOT wear rings or watches during operation. sb3.1* 1/94 12 6-2. IH/TS Setup 6-2-1. Select Power Source Energize the power source, cooler , and IH/TS. A power source sele ...

  • Miller Electric IH - page 21

    OM-203 185 Page 17 6-2-2. Time Date Setup − Digital 6-2-2-1. Digital Recorder Controls Y Keep all panels, doors, and covers closed and secure during programming. 1. Page Up 2. Page Down 3. Left 4. Right 5. Option 6. Menu Additional keys that appear as needed for specific applications are as follows: 7. Close Folder 8. Open Folder 9. Left Cursor 1 ...

  • Miller Electric IH - page 22

    OM-203 185 Page 18 In general, for those locations that observe DST : DST begins at 2:00 am on the first Sunday in April. DST ends at 2:00 am on the last Sunday in October . See “http://deil.lang.uiuc.edu/web.pages/holidays/DST .html for exceptions. NOTE 8. T ouch Apply . 6-2-2-5. Time And Date Setup 1. T ouch System. 2. T ouch Clock. 3. Adjust t ...

  • Miller Electric IH - page 23

    OM-203 185 Page 19 6-3. Operation 1. Energize IH/TS and power source. A coolant flow error should appear on the IH/TS display . Energize the cooler and the error will clear from the display . 2. Se t up T emperature Profile − per code requirements (see Section 6-3-2 Programming The 2408 Controller). 3. Set up and start Digital Recorder Digital Re ...

  • Miller Electric IH - page 24

    OM-203 185 Page 20 6-3-1. 2408 Controller The 2408 controller in the IH/TS provides a means of establishing a heat profile for heating or stress relieving as dictated by “code” requirements, and controls the power source to meet the programmed profile. The 2408 controller has several screens (main and sub-menu) that are used to monitor status a ...

  • Miller Electric IH - page 25

    OM-203 185 Page 21 6-3-2. Programming The 2408 Controller Identify the “code” requirements for the heat treat. For Preheat program refer to Figure 6-1. For Postweld stress relief program refer to Figure 6-2. For a complex stress relief program (multiple temperature rise and cool rates) refer to Figure 6-3. Use worksheet in Figure 6-4 to help pr ...

  • Miller Electric IH - page 26

    OM-203 185 Page 22 Step to 3 00 ° F as fast as possible Dwell @ 300 ° F for 8 hours Free fall to ambient SEG.n 1 tYPE StEP tGt 300 (step) (deg) SEG.n 2 tYPE dwEl dur 8.0 (soak) (in hrs) SEG.n 3 tYPE End End.t S OP (end) (sets output to 0) 0 50 100 150 200 250 300 350 0 1 02 03 04 05 06 0 Time (minutes) Degrees F Example Pre − heat Profile Figur ...

  • Miller Electric IH - page 27

    OM-203 185 Page 23 Step to 6 00 ° F as fast as possible* Ramp to 1350 ° F @ 600 ° /hr SEG.n 1 tYPE StEP tGt 600 (step) (deg) SEG.n 2 tYPE rmP.r tGt 1350 (ramp rate) SEG.n 3 tYPE dwEl dur 0.5 (soak) (in hrs) 0 200 400 600 800 1000 1200 1400 0 30 60 90 120 150 180 Time (minutes) Degrees F Example Stress Relief Profile SEG.n 4 tYPE rmP.r tGt 600 (r ...

  • Miller Electric IH - page 28

    OM-203 185 Page 24 Step to 600 ° F as fast as possible Ramp to 800 ° F @ 400 ° /hr SEG.n 1 tYPE StEP tGt 600 (step) (deg) SEG.n 2 tYPE rmP.r tGt 800 (ramp rate) SEG.n 4 tYPE dwEl dur 1.0 (soak) (in hrs) 0 200 400 600 800 1000 1200 1400 0.0 1.0 2.0 3.0 4.0 5.0 6.0 Time (hours) Degrees F Example Multi − Step Stress Relief Profile SEG.n 5 tYPE rm ...

  • Miller Electric IH - page 29

    OM-203 185 Page 25 A A TGT C rAtE ( ° /hr) B TGT D dur (hrs) F rAtE ( ° /hr) E TGT SEG.n 1 tYPE StEP (step) TGT (target) (deg) SEG.n 2 tYPE rmP.r (ramp rate) B TGT (target) (deg) C rAtE (deg/hr) D SEG.n 3 tYPE dwEl (soak) dur (duration in hrs) SEG.n 4 tYPE rmP.r (ramp rate) E TGT (target) (deg) F rAtE (deg/hr) SEG.n 5 tYPE End (end) End.t S OP (s ...

  • Miller Electric IH - page 30

    OM-203 185 Page 26 6-3-3. Batch Recording Using 5100 Digital Recorder The batch file generated by the recorder will consist of: GroupDescriptor ~ BatchName ~ T imeDateStamp.uhh The default Group Descriptor is set to “Group”. This setting may be changed to something that relates to the application (i.e. Company , Contract, or Project name). T o ...

  • Miller Electric IH - page 31

    OM-203 185 Page 27 6-3-3-3. Stop Recording 1. T ouch the block with the batch name. 2. T ouch “Stop”. 3. T ouch “Close” − screen returns to the home screen and displays “No Batch In Progress”. If a batch file was not started, the temperature data is still recorded. The Job# (Batch Name), User , Comments, and Recorder ID are not record ...

  • Miller Electric IH - page 32

    OM-203 185 Page 28 6. Close the “Network and Dial-up Connection” window . 7. Close the “Control Panel”. Network Connection (Windows ) 95, 98, ME) 1. Click on “Start”, “Settings”, “Control Panel”. 2. Right click on “Network”. 3. Select “Create Shortcut”. 4. Click on “Y es” to create a shortcut on the desktop. 5. Close ...

  • Miller Electric IH - page 33

    OM-203 185 Page 29 3. Click on “Instrument”, “File Services”. 4. Click on “Generic”. 5. Enter user name: “user” (leave password field blank). 6. Click on “OK”. 7. Right click on desired files and transfer them following the procedures in Sections 6-3-6 and 6-3-7. 6-3-3-5-5. T roubleshooting Connection Problems 1. Click on “Sta ...

  • Miller Electric IH - page 34

    OM-203 185 Page 30 6-3-4. Running A Program T o Preheat Or Stress Relief T o start the Heat T reat operation, proceed as follows: Press the “RUN” button − The blue “Heat On” light turns on and the power source energizes. The power source parameters are displayed on the “Parameter Display”. The controller flashes “Hold” until the m ...

  • Miller Electric IH - page 35

    OM-203 185 Page 31 6-3-5. Recovering From An Interruption Press the “RUN” button to start profile. There are two conditions the controller looks at to determine: 1) If it should supply output power and 2) If the power source contactor should be on. 1) If the current temperature is more than 10 5 F above the target temperature in segment 1, the ...

  • Miller Electric IH - page 36

    OM-203 185 Page 32 6-3-6. V iewing Data In Review Software 6-3-6-1. Installing Review Software And First Time Setup Insert the “Chessell 5000 Series Data Management System” CD into the computer . If the installation program does not automatically start, browse to the CD using “My Computer” and run “Setup.exe”. Place a check in the box n ...

  • Miller Electric IH - page 37

    OM-203 185 Page 33 There are three files used to produce a chart in Review software as follows: 1. The .uhh file contains the actual temperature data downloaded from the recorder . 2. The c:Program FilesEurothermReviewReview.erv file contains a copy of the original data and any annotations added in the Review software. 3. The .cgp file contains ...

  • Miller Electric IH - page 38

    OM-203 185 Page 34 scrn38 Select “Files” . scrn3 Select the “history” folder on the floppy drive or browse to the folder on the PC that contains the .uhh files. ...

  • Miller Electric IH - page 39

    OM-203 185 Page 35 Single File With Batch Name scrn4 Select the desired file (highlight file name). The file name consists of: Group_Descriptor ∼ Batch_Name ∼ Time/Date_stamp.uhh For example: Miller~W41 − 1321 − 1 − S~80098A200000014B. uhh Select “Open” . scrn5 Enter the Job# (Batch Name) in the field next to “ Select or Enter Instr ...

  • Miller Electric IH - page 40

    OM-203 185 Page 36 Single File With No Batch Name scrn6 Data is continuously stored in the recorder . If a batch was not started, the temperature data is still recorded. The Job# (Batch Name), User , Comments and Recorder ID are not recorded. The file name would consist of: Group_Descriptor ∼ T ime/Date_stamp.uhh (no Batch Name). The file creatio ...

  • Miller Electric IH - page 41

    OM-203 185 Page 37 Multiple Files With Batch Names scrn8 Data is continuously stored in the recorder . The file name consists of: Group_Descriptor ∼ Batch_Name ∼ Time/ Date_stamp.uhh Select the desired files. Select “Open” . Multiple Files With No Batch Names scrn9 If a batch was not started, the temperature data is still recorded. The Job# ...

  • Miller Electric IH - page 42

    OM-203 185 Page 38 scrn1 1 New instrument is displayed. Select “ OK ” to add the Instrument tag. scrn12 Select “ File ”. Select “ New Chart ”. scrn13 Select “ Add Point ”. ...

  • Miller Electric IH - page 43

    OM-203 185 Page 39 scrn14 Select Instrument, this is the Instrument tag [Job# (Batch Name)] that was entered previously . scrn15 Select the appropriate Log Group. Select Point ID to add a specific point, then select “ OK ” or Select “ Add All ”. ...

  • Miller Electric IH - page 44

    OM-203 185 Page 40 scrn16 Change “Grid Major divisions:” to 30 resulting in 50 ° increments from 0-1500 ° F . Select “ OK ” to view chart scrn17 This display is the default view of the profile. Note the values show “No data” which is due to the dashed line on the right side of the screen being outside of the data values. ...

  • Miller Electric IH - page 45

    OM-203 185 Page 41 scrn18 Drag the slider on the left down to zoom the view out. Click the maximize box to enlarge to full screen. Click on the profile, the dashed line moves to the cursor location. The values at the cursor location appear on the right side of the screen. . These steps must be done in sequence for Batch information to display prope ...

  • Miller Electric IH - page 46

    OM-203 185 Page 42 scrn20 T o remove a TC, click on the TC# (Point ID), then click “ Delete Point ”. T o edit a TC trace properties, select a TC# (Point ID), then click “ Point Properties... ”. Select “ OK ” to return to the chart. scrn21 Span − dictates the range of tem- perature to plot for the trace. Interpolation On − will show ...

  • Miller Electric IH - page 47

    OM-203 185 Page 43 scrn22 Comments can be added to the chart by selecting “ Annotate ” from the Chart Menu . scrn23 Add comments in the Annotation field. Add time manually . Select “OK ”. (10:56:00 A M) scrn24 A warning will appear on the display stating that once added, the com- ment cannot be deleted or changed. Select “OK ”. The comm ...

  • Miller Electric IH - page 48

    OM-203 185 Page 44 scrn25 Save chart to floppy disk by select- ing “File”, then select “Save chart As...” scrn26 / scrn27 Select a path to “ Save in ”. Enter “ File name ” to save as. . File name should be the same as the Instrument name and Job# (Batch Name) for consistency . Select “ Save ”. ...

  • Miller Electric IH - page 49

    OM-203 185 Page 45 scrn28 The file name becomes part of the chart scrn29 Select “ File ”. Select “ Print ” to print entire profile on one page. ...

  • Miller Electric IH - page 50

    OM-203 185 Page 46 scrn30 Select “ Batch ”. Click in check box to select “ Print entire batch ”. Select “ Batch Name “ from pull down menu. Select “ Print ”. ...

  • Miller Electric IH - page 51

    OM-203 185 Page 47 6-3-8. T ypical Profile Chart Printout ...

  • Miller Electric IH - page 52

    OM-203 185 Page 48 SECTION 7 − CONFIGURING CONTROLLER AND RECORDER 7-1. Changing Controller Operating Window , Ramp, Dwell, Or T emperature Units Use the following instructions if changes are required to Operating Window , Ramp, Dwell, or T emperature units. NOTE Press Page to AccS LiSt codE 0 Y codE 1 W ait 2 sec. codE PASS Goto OPEr Y to Goto F ...

  • Miller Electric IH - page 53

    OM-203 185 Page 49 7-2. Changing 5100V Recorder From Degrees F to Degrees C And Change TC Descriptor scrn32 Log in as “ Engineer ” (see Section 6-2-2-2 ). Press “ Menu ” (bottom right of display). Select “ Config “. Select “ Channels ” from pull down menu. scrn33 For each Channel Number (1-6): 1. Select “ Channel Number ”. 2. Ma ...

  • Miller Electric IH - page 54

    OM-203 185 Page 50 7-3. Restoring Recorder Configuration From A Floppy Disk (For 5100 Digital Recorder) Login as Engineer . T ouch top left corner (Logged Out) or (User). T ouch Blue text (pull down menu) next to User . T ouch Engineer . T ouch Password field. T ouch Numeric. T ouch 1, then 0, then Ok. 7-3-1. Load File Insert digital recorder confi ...

  • Miller Electric IH - page 55

    OM-203 185 Page 51 7-3-3. Time Setup 1. T ouch System. 2. T ouch Clock. 3. Adjust time, if necessary . 4. T ouch Apply . 7-3-4. Login As User 1. T ouch top left corner (Engineer). 2. T ouch pull down next to User . 3. T ouch User from pull down list. 7-3-5. Go T o Home Screen 1. T ouch key in bottom right corner to open Root Menu. 2. T ouch Home. ...

  • Miller Electric IH - page 56

    OM-203 185 Page 52 SECTION 8 − MAINTENANCE & TROUBLESHOOTING 8-1. Routine Maintenance T urn Off all power before maintaining. 3 Months OR Blow Out Or V acuum Inside Replace Unreadable Labels 6 Months Replace Cracked Parts 8-2. T roubleshooting T rouble Remedy IH/TS does not power up. Be sure that power switch on rear of IH/TS is in the On pos ...

  • Miller Electric IH - page 57

    OM-203 185 Page 53 T rouble Remedy If display flashes no.io again, or if 0-10 V output card fails. Remove 2408 control from its housing by pressing locking tabs outward slightly on sides of control and pulling control forward. Look for add − on PC card in back of controller , and remove PC card. Reinstall 2408 control into housing being careful n ...

  • Miller Electric IH - page 58

    OM-203 185 Page 54 T rouble Remedy 2408 T emperature Controller reads greater than 5 ° F different than Channel 1 on 5100V Recorder . See Section 8-3I. 2408 T emperature Controller readings fluctuate rather than remain stable. Check and secure connections to the workpiece. 5100V Recorder screen blinks when touched, but does not advance to next scr ...

  • Miller Electric IH - page 59

    OM-203 185 Page 55 8-3. Diagnostic Procedures For IH/TS A. Parameter Display Does Not Operate, But 2408 T emperature Controller And 5100V Recorder Displays Do Operate. T urn on power source. Remove 14-pin control cable from power source and IH/TS. Check for bent pins in 14-pin control cable and on IH/TS receptacle. Check for +24 volts dc between pi ...

  • Miller Electric IH - page 60

    OM-203 185 Page 56 Check for 1 15 volts ac at plug on rear of recorder and reseat plug. If 1 15 volts ac is not present, check wiring between plug PLG4, receptacle RC4, and power switch. If 1 15 volts ac is present at plug on rear of recorder , check that green LED is illuminated by viewing through louvers on side of recorder . A green LED should b ...

  • Miller Electric IH - page 61

    OM-203 185 Page 57 Check Flow/Limit light for illumination. If light does not illuminate, replace circuit board PC1. If light does illuminate, proceed as follows: Check switch leads for continuity when switch is activated. Check switch leads for open circuit when switch is deactivated. If continuity is always present at switch leads, replace flow s ...

  • Miller Electric IH - page 62

    OM-203 185 Page 58 Ribbon cable may be disconnected inside of recorder after prior maintenance, reconnect ribbon cable. If above procedures do not clear the error message, replace recorder . I. 2408 T emperature Controller Reads Greater Than 5 5 F Different Than Channel 1 On 5100V Recorder Remove IH/TS wrapper . Check that red ( − ) and yellow (+ ...

  • Miller Electric IH - page 63

    OM-203 185 Page 59 8-5. Factory Set Parameters If it becomes necessary to return to factory settings, the following sections list factory settings for the 2408 controller . All settings can be accessed through the Goto screen. T o access the Goto screen, proceed as follows: Press Page to AccS LiSt codE 0 Y codE 1 W ait 2 sec. codE PASS Goto OPEr Go ...

  • Miller Electric IH - page 64

    OM-203 185 Page 60 8-5-2. 2408 Controller Edit Parameters Goto Edit Home Run P ro gr a m m e r Alarm Autotune PID Setpoint I nput Output Information Access List List List List List List List List List List List 74 run ProG A L Atun Pid S P iP oP inFo ACCS rEAD rEAd rEAd HIdE HIdE HIdE HIdE HIdE HIdE HIdE LiSt 74 StAt Hb % f ALtr HIdE OP PS P Hb U A ...

  • Miller Electric IH - page 65

    OM-203 185 Page 61 8-5-3. 2408 Controller Full Parameters (Prior T o V ersion V4.09) Goto FuLL Ho me Run Programmer Alarm Autotune P I D Setpoint Input Output Information Access List List List List List List List List List List List 74 run ProG AL Atun P i d SP i P oP inFo ACCS 100 LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt 74 StAt H b 1dHi ...

  • Miller Electric IH - page 66

    OM-203 185 Page 62 8-5-4. 2408 Controller Configure Parameters (Prior T o V ersion V4.09) Goto conF Process Logical Logical Alarm Instrument V alue Input Setpoint Alarms Programmer Inputs A Inputs B relay Comms 1 Comms 2 Module 1 Module 2 Module 3 Calibration P as sw or d Config Config Config Config Config Config Config Config Config Config Config ...

  • Miller Electric IH - page 67

    OM-203 185 Page 63 8-5-5. 2408 Controller Full Parameters (Effective w/V ersion V4.09) Goto FuLL Ho me Run Programmer Alarm Autotune PI D Setpoint Input Output Information Access List List List List List List List List List List List 74 run ProG AL Atun P i d SP i P oP inFo ACCS 100 LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt LiSt 74 StAt H b 1dHi ...

  • Miller Electric IH - page 68

    OM-203 185 Page 64 8-5-6. 2408 Controller Configure Parameters (Effective w/V ersion V4.09) Goto conF Process Logical Logical Alarm Instrument V alue Input Setpoint Alarms Programmer Inputs A Inputs B relay Comms 1 Comms 2 Module 1 Module 2 Module 3 Calibration P as sw or d Config Config Config Config Config Config Config Config Config Config Confi ...

  • Miller Electric IH - page 69

    OM-203 185 Page 65 8-6. Calibration Certification Procedure The following items are required for verifying calibration: 1. Fluke-714 Thermocouple Calibrator this can be obtained from: http://www .fluke.com/products/home.asp?SID=13&AGID=9&PID=1707 specify primary standard certification when ordering. 2. T ype-K Mini Connector (Fluke #80CK-M) ...

  • Miller Electric IH - page 70

    OM-203 185 Page 66 SECTION 9 − ELECTRICAL DIAGRAMS 215 588-A Figure 9-1. Circuit Diagram For IH/TS ...

  • Miller Electric IH - page 71

    OM-203 185 Page 67 SECTION 10 − P ARTS LIST Ref. 803 005-A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22 25 26 27 28 29 30 32 34 35 36 37 38 39 40 41 42 43 23 24 17 33 31 Figure 10-1. Complete Assembly Description Part No. Dia. Mkgs. Figure 10-1. Complete Assembly Quantity 1 203 262 NAMEPLA TE, w/o recorder 1 . . . . . . . . . . . . . . . ...

  • Miller Electric IH - page 72

    OM-203 185 Page 68 Description Part No. Dia. Mkgs. Figure 10-1. Complete Assembly (Continued) Quantity 22 198 893 RECEPT ACLE, thermocouple 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 209 948 BRACKET , mtg receptacle RJ45 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric IH - page 73

    Notes ...

  • Miller Electric IH - page 74

    Notes ...

  • Miller Electric IH - page 75

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 1/05 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise o ...

  • Miller Electric IH - page 76

    PRINTED IN USA © 2005 Miller Electric Mfg. Co. 1/05 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Comp any 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters − USA USA Phone: 920-735-4505 Aut o-At tended USA & Canada F A X: 920-735-4134 Int ernati onal F AX : 920-735-4125 European Headqua rters − United K ...

メーカー Miller Electric カテゴリー Welder

Miller Electric IHのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IHの取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric IHの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric IHの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric IHの取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric IHのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric IHの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miller Electric IHデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric IHを使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric IHユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric IHの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric IHの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric IHに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric IHデバイスの基本機能を使うにあたってのヒント。 Miller Electric IHのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric IHに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric IHのメーカー/サービスへの連絡先に関する情報。

Miller Electric IHについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric IHの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric IHで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)