    Digital Blood Pressure Monitor Model UA-767 BT Instruction Manual Original Manuel d ’ instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung Gebruiksaanwijzing Vertaling 使用手冊 1WMPD4001357D 翻譯 ...

  • A&D UA-767PBT-C40 - page 2

    English 1 Contents Dear Customers .................................................................... 1 Preliminary Remarks ............................................................. 2 Precautions ........................................................................... 2 Parts Identification .................................................. ...

  • A&D UA-767PBT-C40 - page 3

    English 2 Preliminary Remarks This device conforms to the Europe an Directive 93/42 EEC for Medical Products. This is made evident by the mark of conformity. (0123: The reference number to the involved notified body) The device complies with the statutory EMC (Electromagnetic Compatibility) directive 89/336/ EEC. The WML-40AH is approved in accorda ...

  • A&D UA-767PBT-C40 - page 4

    English 3 To measure blood pressure, the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery. This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively. Any pain, numbness, or red marks will disappear with time. Contrai ...

  • A&D UA-767PBT-C40 - page 5

    English 4 Part s Identification Part of Display Pressure Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator I . H. B . I n d i c a t o r (Irregular heartbeat indicator) Heart Mark Display Air Connector Plug Air Socket Arm Cuff DC Jack START Button Air Hose Index Mark Proper Fit Range Artery Position Mark Battery ...

  • A&D UA-767PBT-C40 - page 6

    English 5 Symbols Symbols Function / Meaning Recommended Action Standby and power on. Battery installation guide Direct current SN Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is in progress. It blinks when the pu ...

  • A&D UA-767PBT-C40 - page 7

    English 6 Using the Monitor Inst alling / Changing the Batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as show n, taking care that the polarities (+) and (-) are correct. 3. Slide the battery cover down to close. Use only R6P, AA batteries. CAUTION Insert the bat ...

  • A&D UA-767PBT-C40 - page 8

    English 7 Using the Monitor Selecting the Correct Cuff Size Using the correct cuff size is important for an accurate readi ng. If the cuff is not the proper size, the reading may yield an i ncorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuff, te ll you if you are applying the correct cuff ...

  • A&D UA-767PBT-C40 - page 9

    English 8 Using the Monitor Applying the Arm Cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown. Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error. 2. Constriction of the upper arm, caused by tightly rolling up a shirtsleeve, may prevent acc ...

  • A&D UA-767PBT-C40 - page 10

    English 9 Measurement s Model UA-767 BT is designed to detect th e pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expec ted to exceed 230 mmHg or you use the optional small cuff, read "Measurem ent with the desired systolic pressure" on the next page. Normal Measurement 1. Place the ...

  • A&D UA-767PBT-C40 - page 11

    English 10 Measurements Measurement with the Desired Systolic Pressure If your systolic pressure is expect ed to exceed 230 mmHg or you use the optional small cuff, use this procedure. 1 . P la c e t h e c u f f on t h e arm (preferably the left arm). 2. Press and hold the START button until a number about 30 to 40 mmHg higher than your expected sy ...

  • A&D UA-767PBT-C40 - page 12

    English 11 What is an Irregular Heartbeat Model UA-767 BT blood pressure monitor provides a blood pressure and pulse rate measurement ev en when an irregular heartbeat occurs. An irregular heart beat is defined as a heart beat that varies by 25% from the average of all heart beats during the blood pressure measurement. It is important that you be r ...

  • A&D UA-767PBT-C40 - page 13

    English 12 Reference Material: Journal of Hyperte nsion 1999, Vol 17 No.2 mmHg 110 105 100 95 90 85 80 Optimal 120 130 140 150 160 170 180 Systolic blood pressure mmHg Normal High-normal Grade 1 hypertension (mild ) Grade 2 hypertension (mode rate) Grade 3 hypertension (severe) Diastolic blood pressure About Blood Pressure What is Blood Pressure? B ...

  • A&D UA-767PBT-C40 - page 14

    English 13 Typical fluctuation within a day (Measured every five minutes) PM AM Time Diastolic blood pressure Systolic Diastolic Sleep described in this manual to get to know your normal blood pressure. R egular readings give a more comprehensive bl ood pressure history. Be sure to note date and time when recording your blood pressure. Consult your ...

  • A&D UA-767PBT-C40 - page 15

    English 14 Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be da maged. If you cannot fix the problem using the troubleshooting instructi ons, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare part s ...

  • A&D UA-767PBT-C40 - page 16

    English 15 Applied part Cuff Type BF Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Wireless communication WML-40AH (M ITSUMI Electronics Co. Ltd.) Accessory AC adapter The adapter is to connect the device to a power source at home. TB-233 Please contact your local A&D dealer for purchasing. Th ...

  • A&D UA-767PBT-C40 - page 17

    1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Busi ness Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550 420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jo se, Cal ...

メーカー A&D カテゴリー Sphygmomanometer

A&D UA-767PBT-C40のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- UA-767PBT-C40の取扱説明書
- A&Dの製品カード
- パンフレット
- またはA&D UA-767PBT-C40の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A&D UA-767PBT-C40の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A&D UA-767PBT-C40の取り付け説明書、サービスマニュアル、簡易説明書、またはA&D UA-767PBT-C40のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A&D UA-767PBT-C40の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A&D UA-767PBT-C40デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA&D UA-767PBT-C40を使用するのを助ける技術的文書のことです。説明書は通常、全てのA&D UA-767PBT-C40ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A&Dの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A&D UA-767PBT-C40の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA&D UA-767PBT-C40の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A&D UA-767PBT-C40に関してこのドキュメントで見つけることができる全てのヒントの目次
3. A&D UA-767PBT-C40デバイスの基本機能を使うにあたってのヒント。 A&D UA-767PBT-C40のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A&D UA-767PBT-C40に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA&D UA-767PBT-C40のメーカー/サービスへの連絡先に関する情報。

A&D UA-767PBT-C40についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA&D UA-767PBT-C40の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA&D UA-767PBT-C40で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください