American Aldes DHV-150Hの取扱説明書

19ページ 0.29 mb
ダウンロード

ページに移動 of 19

Summary
  • American Aldes DHV-150H - page 1

    F: W06 AldesW06 DOCFILES 782DHV - 150HInst.doc 782DHV150H - 10 - 00 Rev: 10 / 30 / 2002 DHV - 150H DEHUMIDIFYING VENTILATOR INSTALLATION OPERATION MAINTENANCE 782DHV12 - 00 DHV - 150H Indoor Air Quality System Installation, Operation & Service Instructions Table of Contents 1. Specifications ............................................. ...

  • American Aldes DHV-150H - page 2

    2 • Avoid dischargi ng the air directly at people, or over the water in pool areas. • If used near a pool or spa, be certain there is NO chance the unit could fall into the water or be splashed and that it is plugged into a GROUND FAULT INTERRUPTER. • DO NOT use the DHV - 150H a s a bench or table. • A drain pan MUST be placed under the uni ...

  • American Aldes DHV-150H - page 3

    3 An optional condensate pump kit may be installed if a lift is required to dispose of the condensate. The cond - ensate pump kit can be ordered direct from the factory. See the optional par ts list for information on the kit. 2.4 Ducting 2.4A Installing Duct Collars The DHV - 150H is equipped with 10” and 6” round inlet collars and a 10” rou ...

  • American Aldes DHV-150H - page 4

    4 posit ively or negatively, depending upon the inside and outside air conditions. Consult the factory by calling 1 - 800 - 255 - 7749 for recommendations regarding the use of higher flows with your specific application. The outside air duct should be connected to the 6” round collar on the filter enclosure of the unit. The 6” round collar incl ...

  • American Aldes DHV-150H - page 5

    5 2.5 Quiet Ins tallation Remove Shipping Restraints The compressor is attached to the cabinet with two cable ties to secure it during shipment. This rigid attachment is not necessary once the unit is installed and may cause noise from compressor vibration . AFTER INSTAL LATION, CUT THE CABL E TIES TO FREE THE COMPRESSOR FROM THE CABINET. RE MOVE T ...

  • American Aldes DHV-150H - page 6

    6 Figure 1: DHV - 150H in a Basement With a Forced Air System Incorporating a Central Return Figure 2: DHV - 150H in an Attic with a Forced Air System Incorporating a Cent ral Return ...

  • American Aldes DHV-150H - page 7

    7 3 Operation The DHV - 150H can be equipped with various accessories to enhance its operation. A remote control panel must be used with the DHV - 150H. There are two remote control panels from which to choose. The humidity/fan control panel is use d to control humidity and the fan. The ventilation timer and humidity control panel is used to contro ...

  • American Aldes DHV-150H - page 8

    8 The ventilation timer is an electronic timer that displays the current time. This timer has a battery backup, so it will not req uire resetting after a power outage. Following a prolonged power outage the display of the timer will flash on and off indicating a power outage has occurred. The one - minute time increments of the ventilation timer al ...

  • American Aldes DHV-150H - page 9

    9 4 Maintenance 4.1 Standard Air Filter The DHV - 150H is equipped with a pleated cloth air filter. This filter should be checked semi - annually. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency and may cause the co mpressor to cycle off and on unnecessarily on the defrost control. To access the air filter, r ...

  • American Aldes DHV-150H - page 10

    10 maintain nearly constant pressure and temperature across the entire coil, from inlet to outlet. The mixture of gas and liquid refr igerant enter the accumulator after leaving the evaporator coil. The accumulator prevents any liquid refrigerant from reaching the compressor. The compressor evacuates the cool refrigerant gas from the accumulator an ...

  • American Aldes DHV-150H - page 11

    11 6. Turn on the fa n switch; the fan should run. Turn off the fan switch. 7. Turn on the humidity control; the compressor and fan should run. 8. If these tests work, the problem is most likely in the field control wiring. 5.4 Refrigerant Charging If the refrigerant charge is los t due to service or a leak, a new charge must be accurately weighed ...

  • American Aldes DHV-150H - page 12

    12 in the compressor mot or, the resulting high temperature arc causes a portion of the refrigerant oil mixture to break down into carbonaceous sludge, a very corrosive acid, and water. These contaminants must be carefully removed otherwise even small residues will attack replacem ent compressor motors and cause failures. The following procedure is ...

  • American Aldes DHV-150H - page 13

    13 5.7B Programmable Ventilation Timer The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activate d, the central conditioning unit will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence. The home shou ...

  • American Aldes DHV-150H - page 14

    14 Figure 4. Electric Schematics of the DHV - 150H ...

  • American Aldes DHV-150H - page 15

    15 Figure 5: Pictorial Electrical Diagrams of DHV - 150H ...

  • American Aldes DHV-150H - page 16

    16 SERVICE PARTS LI ST: DHV - 150H Indoor Air Quality System ITEM PART NO. QTY. DESCRIPTION 1 AL98996 1 Air Filter, Pleated Cloth 2 4017777 2 Capillary Tube, .059" X .124" X 32.00" (not shown) 3 4023645 1 Compressor Service Kit, Carlyle (EBA120111A) (Includes Compresso r, Capacitor & Overload) 4 4022595 1 Compressor Overload (EBA ...

  • American Aldes DHV-150H - page 17

    17 OPTIONAL PARTS LIST: DHV - 150H Indoor Air Quality System ITEM PART NO. QTY. DESCRIPTION 25 AL9899 5 1 Air Filter, High Efficiency, Pleated Microglass Paper, 90 % - 95 % 26 AL99027 1 Check Damper, 10" Diameter (not shown) 27 AL99006 1 Condensate Pump Kit, External 28 4024155 1 Control Panel Assembly, Humidity/Fan 29 4024125 1 Control Panel ...

  • American Aldes DHV-150H - page 18

    18 Limited Warranty American ALDES Ventilation Corporation warran ts to the original end user of the Dehumidifier or Dehumidifying Ventilator model referred to below, to be free from manufacturing defects. It is limited to the original end - user and may not be assigned or transferred. First Year Warranty: If the produc t exhibits a defect in mater ...

  • American Aldes DHV-150H - page 19

    19 Date Service Notes ...

メーカー American Aldes カテゴリー Ventilation Hood

American Aldes DHV-150Hのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DHV-150Hの取扱説明書
- American Aldesの製品カード
- パンフレット
- またはAmerican Aldes DHV-150Hの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Aldes DHV-150Hの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Aldes DHV-150Hの取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Aldes DHV-150Hのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Aldes DHV-150Hの製品を使用するにあたって最も人気のある説明書を閲覧できます。

American Aldes DHV-150Hデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Aldes DHV-150Hを使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Aldes DHV-150Hユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Aldesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Aldes DHV-150Hの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Aldes DHV-150Hの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Aldes DHV-150Hに関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Aldes DHV-150Hデバイスの基本機能を使うにあたってのヒント。 American Aldes DHV-150Hのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Aldes DHV-150Hに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Aldes DHV-150Hのメーカー/サービスへの連絡先に関する情報。

American Aldes DHV-150Hについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Aldes DHV-150Hの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Aldes DHV-150Hで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください