    INST ALLA TION INSTRUCTIONS 62-0258 T7351 Commercial Programmable Thermostat FOR SINGLE- OR MULTI-STAG E CONVENTIONAL/HEAT PUMP SYSTEMS APPLICA TION The T7351 Commerci al Programm able Therm ostat controls 24 V a c commercial sing le zone heating, ventilating and air conditioning (H V AC) equipm ent. The T7351 cons ists of a thermo stat an d subbas ...

  • Honeywell T7351 - page 2

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT 62-0258 2 Fig. 1. T ypical location of t hermost at or remote-mount ed sensor . Mounting Subbase The subbase moun ts horizontally . IMPORT ANT • When using the intern al temperature or hu midity sensor , the device m ust be mounted horizont ally (with the LCD fac ing upwards). Pr ecise leveling is not need ...

  • Honeywell T7351 - page 3

    T7351 COMMERC IAL PROGRAMMABLE THER MOSTAT 3 62-0258 Fig. 4. Mounti ng thermost at on subbase. Wiring Follow equipment manu facturer wiring instructio ns when availabl e. Ref er to th e Wiring Diagra m secti on for t ypical hookups. A letter cod e is located near e ach terminal fo r identification. IMPORTANT All wiring must comply with lo cal elect ...

  • Honeywell T7351 - page 4

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT 62-0258 4 Fig. 5. Th ermostat key loc ations. INST ALLER SETUP For most app lications, the the rmostat factory settin gs do not need to be chan ged. Revi ew the fac tory set t ings in T ab le 2. NOTE: When pow er is firs t applie d to the th ermostat, the display will show all segm ents (see Fig. 6). T able ...

  • Honeywell T7351 - page 5

    T7351 COMMERC IAL PROGRAMMABLE THER MOSTAT 5 62-0258 T able 3. Installer Setup . T ext Default Choices Notes DEGREES 0 0 -1 Degree T emperature Fo rmat 0: Degrees F 1: Degrees C CLOCK 0 0 - 1 Clock Display Format 0: 12 hour 1: 24 hour KEYLOCK 0 0 - 3 Keypad Lockout Level 0: None 1: Lockout all k eys except Set Day , Set Time, Set Date, Set Holidays ...

  • Honeywell T7351 - page 6

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT 62-0258 6 XF AN HT YES YES or NO Extended Fan on Heat NO: None YES: 90 seconds XF AN CL NO YES or NO Extended Fan on Cool NO: None YES: 40 seconds STRTD EL 0 0 - 15 Sequentia l S tart Delay 0 to 150 seco nds in 10 secon d increments ADV ANCE NO YES or NO Advanced Settings NO: Hide YES: Show TMP LIM 3 0 - 5 T ...

  • Honeywell T7351 - page 7

    T7351 COMMERC IAL PROGRAMMABLE THER MOSTAT 7 62-0258 Holidays and 365 - Day Clock The T7351can be configured to schedule up to 10 separate holidays, e ach with a duration of up to 99 d ays. T o en able this func tion, the user m ust set the da te: 1. Press Set Day and Set T ime keys simultaneously . 2. Use the Up/Down key s to set the date to YES, ...

  • Honeywell T7351 - page 8

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT 62-0258 8 a On: Continuous fan operation ( occupied and standby). Dur ing not occupied per iods, fan cycles wit h call for heat or cool. Auto: Fan cycles with call for heat or cool during all per iods. (See P roduct Data Sheet, for m 63-2605, f or more details). NOTES: The dis play retu rns to defa ult scree ...

  • Honeywell T7351 - page 9

    T7351 COMMERC IAL PROGRAMMABLE THER MOSTAT 9 62-0258 Get Factory Schedule (Info/Clear) Performing this operation reve rts the schedules to the factory defaults: 1. Press both Info an d Clear S tart Time . 2. The display give s the option to revert to FAC SCH. a. T o restore th e factory sched ule, press up ! or down " until the display indicat ...

  • Honeywell T7351 - page 10

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT 62-0258 10 Options Utilizing Auxiliary Output There are two dehumidification o ptions that utilize the auxiliary output. They are: — Simple De humidificatio n. — Hot Gas Bypass Dehumid ification. Simple Dehumid(ification) The auxiliary output: — Energizes whe n RH rises above humidity high limit. — D ...

  • Honeywell T7351 - page 11

    T7351 COMMERC IAL PROGRAMMABLE THER MOSTAT 1 1 62-0258 Fig. 9. T y pical ho okup of T7 350F2010 in three-stage heat and three-s tage cool convent ional sys tem with one tran sformer . TROUBLESHOOTING GUIDE (T ABLE 7) T able 7. T roublesho oting I nformation. Symptom Possible Caus e Action Display will not come on. Thermostat is not be ing powered. ...

  • Honeywell T7351 - page 12

    T7351 COMMERCIAL PROGRAMMABLE THERMOSTAT Automation and Cont rol Solution s Honeywell Internatio nal Inc. Honeywell Limite d-Honeywell Limitée 1985 Douglas Dr ive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Onta rio M1V 4Z9 customer.hone ywell.com ® U.S. Regi stered T rademark © 2007 Hone ywell Interna tional Inc. 62-0258 J.I. 01-07 ...

メーカー Honeywell カテゴリー Thermostat

Honeywell T7351のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- T7351の取扱説明書
- Honeywellの製品カード
- パンフレット
- またはHoneywell T7351の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Honeywell T7351の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Honeywell T7351の取り付け説明書、サービスマニュアル、簡易説明書、またはHoneywell T7351のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Honeywell T7351の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Honeywell T7351デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHoneywell T7351を使用するのを助ける技術的文書のことです。説明書は通常、全てのHoneywell T7351ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Honeywellの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Honeywell T7351の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHoneywell T7351の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Honeywell T7351に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Honeywell T7351デバイスの基本機能を使うにあたってのヒント。 Honeywell T7351のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Honeywell T7351に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHoneywell T7351のメーカー/サービスへの連絡先に関する情報。

Honeywell T7351についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHoneywell T7351の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHoneywell T7351で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)