Juniper Networks 200の取扱説明書

40ページ 1.02 mb
ダウンロード

ページに移動 of 40

Summary
  • Juniper Networks 200 - page 1

    N ET S CREEN -200 S ERIES User’s Guide Version 5.0 P/N 093-1253-000 Rev. C ...

  • Juniper Networks 200 - page 2

    Copyright Notice Copyright © 2007 Juniper Networks , Inc. All rights reserved. Juniper Networks, the Juniper Networks logo, NetScreen, Ne tScreen Techn ologies, GigaScr een, and the Ne tScreen log o are registered trademarks of Juniper Netw orks, Inc. Ne tScreen-5GT, NetScreen-5XP, NetScreen-5XT, NetScreen-25, NetScreen-50, NetScreen-100, NetScree ...

  • Juniper Networks 200 - page 3

    NetScreen-200 Series iii Contents Preface ................ .............. .............. .............. .............. .............. .............. .............. ...... ............. .......... v Guide Organization ..................................... ................................ ............................. v Command Line Interface (CLI) C ...

  • Juniper Networks 200 - page 4

    Contents iv User’s Guide Establishing a Termin al Emulator Connection ................................... ............. 22 Changing Your Admin Name an d Password ........................................... ...... 23 Setting Port and Interface IP Addresses ......................................................... 23 Viewing Current Interface Setti ...

  • Juniper Networks 200 - page 5

    NetScreen-200 Series v Preface The Juniper Networks NetScreen-200 Series consists of vers atile, purpose-built, high- performance security system s that provide IPSec VPN and firewall services for medium and large enterprise offices, e-business sites, data centers, and carrier infrastructures. The NetScreen-200 Series includes the following device ...

  • Juniper Networks 200 - page 6

    Preface vi User’s Guide C OMMAND L INE I NTERFACE (CLI) C ONVENTIONS The following conventions are used when pr esenting the syntax of a command line interface (CLI) comman d: • Anything inside square brackets [ ] is optional. • Anything insi de braces { } is required. • If there is more than one choice, each choice is separ ated by a pipe ...

  • Juniper Networks 200 - page 7

    NetScreen-200 Series 1 1 Chapter 1 Overview This chapter provides detail ed descriptions of the NetScr een-200 Series syst em devices and their components. Topics in this chapter include: • “NetScreen-200 Systems” on page 2 – “NetScreen-204 Device” on page 2 – “NetScreen-208 Device” on page 2 • “The Front Panel” on page 3 ? ...

  • Juniper Networks 200 - page 8

    Chapter 1 Overview 2 User’s Guide N ET S CREEN -200 S YSTEMS This NetScreen-200 Series currently includes the NetS creen-204 device and the NetScreen-208 device. NetScreen-204 Device The NetScreen-204 is a chassis-based, rack-mou ntable network security device with four ethernet 10/100 Base-T interface ports. Th e figure below shows a NetScreen-2 ...

  • Juniper Networks 200 - page 9

    The Front Panel NetScreen-200 Series 3 T HE F RONT P ANEL The features shared in common by Net Scre en-204 a nd NetScre en-208 devices include: • A System Status LED display • An Asset Recovery Pinhole • A Console port • A Modem port • A Compact Flash Card Slot • Ethernet interfaces System Status LED Display The front panel of each NetS ...

  • Juniper Networks 200 - page 10

    Chapter 1 Overview 4 User’s Guide Asset Recovery Pinhole The Asset Recovery Pinhole is a button that resets the device to its original default settings. To use this button, i nsert a stiff wire (such as a straightened pa per clip) into the pinhole. Alarm System Alarm red Critical alarm: • Failure of hardware component or software module (such a ...

  • Juniper Networks 200 - page 11

    The Front Panel NetScreen-200 Series 5 Console and Modem Ports The Console port is an RJ-45 serial console port connector, for vt100 terminal emulator programs to perform local conf iguration and administra tion. The Modem port is an RJ-45 serial console po rt connector, for establishing remote console sessions using dialup connections throug h a 9 ...

  • Juniper Networks 200 - page 12

    Chapter 1 Overview 6 User’s Guide Ethernet Interfaces Each Ethernet port is a 10/100 auto-sensing interface with two link LEDs. The left LED indicates network traffic, and the right LED indicates an ac tive network link. T HE R EAR P ANEL The figure below shows the rear panel of a NetScreen -200 Series device (with an AC power suppl y). Power Sup ...

  • Juniper Networks 200 - page 13

    The Rear Panel NetScreen-200 Series 7 Power Fuse Each NetScreen-200 Series device uses a 2.5 Amp, slow-blow power fuse rated for 250 Volts. To replace a fuse on a NetScreen-200 Series device: 1. Take the device off-line by turning the power switch OFF and disconnecting the power cable. 2. Using a screwdriver, separate the lid of the external fuse c ...

  • Juniper Networks 200 - page 14

    Chapter 1 Overview 8 User’s Guide ...

  • Juniper Networks 200 - page 15

    NetScreen-200 Series 9 2 Chapter 2 Installing the Device This chapter describes how to install a device in an equi pment rack or on a desktop, and how to connect the device to other devices. Topics in this chapter include: • “General Instal lation Guid elines” on pa ge 10 • “Performing Equipment-Rack Installation” on page 10 – “Equi ...

  • Juniper Networks 200 - page 16

    Chapter 2 Installing the Device 10 User’s Guide G ENERAL I NSTALLATION G UIDELINES Observing the following pre cautions can p r event injuries, equi p ment failur es and shutdowns. • Never assume that the power su pply is disconnected from a power source. Always check first. • Room temperature might not be sufficie nt to keep equipment at acc ...

  • Juniper Networks 200 - page 17

    Connecting the Power NetScreen-200 Series 11 There are two ways to rack-mount the NetScree n-200 Series: • Front mount • Mid-mount Front Mount To front mount the NetScreen-200 Seri es device on your equipment rack: 1. Screw the front mount bracket to the side of the chassis. 2. Screw the front mount bracket to t he rack, as shown below. Mid-Mou ...

  • Juniper Networks 200 - page 18

    Chapter 2 Installing the Device 12 User’s Guide W IRING A DC P OWER S UPPLY The DC power supply , ON/OFF switch, groundi n g screw, and termi nal blocks, are located in the back of the chassi s of the powe r supply unit. To connect the DC power supply to a grou nding point at your site: 1. Remove the hex nut on the grounding screw. 2. Place the g ...

  • Juniper Networks 200 - page 19

    Connecting the NetScreen-200 Device to Other Devices NetScreen-200 Series 13 C ONNECTING THE N ET S CREEN -200 D EVICE TO O THER D EVICES To connect th e device, use the ethernet interfaces ( ethernet1 through ethern et4 on the NetScreen-204, or ethernet1 through ethernet8 on the NetScree n-208). The pu rpose of each interface depe nds up on the se ...

  • Juniper Networks 200 - page 20

    Chapter 2 Installing the Device 14 User’s Guide ...

  • Juniper Networks 200 - page 21

    NetScreen-200 Series 15 3 Chapter 3 Configuring the Device This chapter descri bes how to perform init ial configura tion on a NetScreen-200 Series device once yo u have mo unted it in a rack or desktop, pl ugged in the ne cessary cables, then turn the power ON. Topics in this chapter include: • “Operational Modes” on page 16 – “Transpare ...

  • Juniper Networks 200 - page 22

    Chapter 3 Configuring the Device 16 User’s Guide O PERATIONAL M ODES The NetScreen-200 Series devi ce supports two device modes: Transparent mode and Route mode. The default mode is Route. Transparent Mode In Transparent mode, the NetScr een-200 device operates as a Layer-2 bridge. Because the device cannot tran slate packet IP addres ses, it can ...

  • Juniper Networks 200 - page 23

    The NetScreen-200 Series Device Interfaces NetScreen-200 Series 17 T HE N ET S CREEN -200 S ERIES D EVICE I NTERFACES Each NetScreen-200 devi ce provides ethernet interfaces for access and connectivity. In addition, there are logica l (non-physical) in terfaces that perform special Layer-2 or management functions. The configurable interfaces avai l ...

  • Juniper Networks 200 - page 24

    Chapter 3 Configuring the Device 18 User’s Guide C ONNECTING THE D EVICE AS A S INGLE S ECURITY G ATEWAY There are many ways to connect a NetScre en-2 00 Series device to your network system. In most cases, the device serv es as a single security gateway that prot ects at least one LAN (usually connected to the de vice from a switch or a hub). Co ...

  • Juniper Networks 200 - page 25

    Connecting the Device as a Single Security Gateway NetScreen-200 Series 19 In the following example, a NetScreen-208 device connects to a protected LAN through ethernet1 (bound to the Trust security zo ne) and to a protected DMZ through ethernet2 (bound to the DMZ security zone). The devi ce connects externally to a router through ethernet3 (bound ...

  • Juniper Networks 200 - page 26

    Chapter 3 Configuring the Device 20 User’s Guide E STABLISHING AN HA C ONNECTION B ETWEEN D EVICES To assure continuous traffic flow in the event of system failure, you can cable and configure two NetScreen devices in a redu ndan t cluster. The devices propag ate all network, configuration and session information to each other. Should one device ...

  • Juniper Networks 200 - page 27

    Establishing an HA Connection Between Devices NetScreen-200 Series 21 To cable two NetScreen-200 Se ries devices together for HA and connect them to the network: 1. (Optional) Install the NetScreen -200 Seri es devices in an equipment rack (see “Equipment Rack Installa tion Guidelines” on page 10 ). 2. Make sure that all ON/OFF po wer supply sw ...

  • Juniper Networks 200 - page 28

    Chapter 3 Configuring the Device 22 User’s Guide Switches 11. Cable together the switches la beled “Switch 3” and “Switch 4.” 12. Cable together the switches labeled “Layer 3 switch 1” and “Lay er 3 switch 2.” 13. Cable the switches labeled “Layer 3 switch 1” and “Layer 3 switch 2” to routers. 14. Turn the power switch es ...

  • Juniper Networks 200 - page 29

    Performing Initial Connection and Configuration NetScreen-200 Series 23 6. At the password prompt, type netscreen . 7. (Optiona l) By defau lt, the console tim e s out and terminates automatically after 10 minutes of idle time. To change this timeout interval, ex ecute the following command: set console timeout number where number is the length of ...

  • Juniper Networks 200 - page 30

    Chapter 3 Configuring the Device 24 User’s Guide Setting the IP Address of the Management Interface To make an interface work as the management interface, yo u must set the IP address and subnet mask to the same address range as your co mputer (or LAN). Use the CLI save command to save your configura tion changes. To configure the ethernet1 inter ...

  • Juniper Networks 200 - page 31

    Configuring the Device for Telnet and WebUI Sessions NetScreen-200 Series 25 Allowing Outbound Traffic By default, th e NetScreen -200 Series de vice does not allow inbound or outbound traffic, nor does it allow traffic to or from the DMZ. To permit (or deny) traffic, you must create access policies. The following CLI command creates an access po l ...

  • Juniper Networks 200 - page 32

    Chapter 3 Configuring the Device 26 User’s Guide 5. (Optiona l) By default, the console tim e s out and terminates automatically after 10 minutes of idle time. To change this timeout interval, ex ecute the following command: set console timeout number where number is the length of idle time in minute s before session termination . To prevent any ...

  • Juniper Networks 200 - page 33

    Configuring the Device for Telnet and WebUI Sessions NetScreen-200 Series 27 The NetScreen WebUI appl ication window app ears. Note: NetScreen-Security Manager 20 04 (NSM) and NetScreen Rapid Deployment (RD): If you are using NSM, you can optionally configure NetScreen appliances with RD . Refer to the Rapid Deployment Getting Started Guide for mor ...

  • Juniper Networks 200 - page 34

    Chapter 3 Configuring the Device 28 User’s Guide A SSET R ECOVERY If you lose the admin password, you can use on e of the following procedures to reset the NetScreen device to its default settings. This destroys any existing configurations, but restores access to the device. Using CLI Commands to Reset the Device To perform this operation, you ne ...

  • Juniper Networks 200 - page 35

    Asset Recovery NetScreen-200 Series 29 Using the Asset Recovery Pinhole to Reset the Device You can also reset the device and restore the fa ct ory default settings by pressing the asset recovery pinhole. To perform this operation, you nee d to make a console connection, as described in “Establishing a Terminal Emulator C onnection” on page 22 ...

  • Juniper Networks 200 - page 36

    Chapter 3 Configuring the Device 30 User’s Guide ...

  • Juniper Networks 200 - page 37

    NetScreen-200 Series A-I A Appendix A Specifications This appendix provid es general system specificatio ns for the NetScreen-200 Series devices. • “NetScreen-200 Attributes” on page A-II • “Electrical Specification” on page A-II • “Environmental” on page A-II • “Safety Certifications” o n page A-II • “EMI Certifications ...

  • Juniper Networks 200 - page 38

    Appendix A Specifications A-II User’s Guide N ET S CREEN -200 A TTRIBUTES Height: 1.73 inches (4 .4 cm) Depth: 10.8 inches (27.4 cm) Width: 17.5 inches (44.5 c m) Weight: 8 pounds (36 hg) E LECTRICAL S PECIFICATION AC voltage: 100-240 VAC +/- 10% DC voltage: -36 to -60 VD C AC Watts: 45 Watts DC Watts: 50 Watts Fuse Rating: 2.5Amps / 250Volts E N ...

  • Juniper Networks 200 - page 39

    Index NetScreen-200 Series IX-I Index A asset recovery 28 B back panel 6 C cables connections 19 power 19 RJ-45 connectors 17 RJ45 connectors 5 , 13 twisted pair 13 , 17 cabling network interfaces 25 power supply 21 changing login and password 23 changing timeout 23 , 26 compact flash card slot 5 configuration, multiple devices 19 connecting power ...

  • Juniper Networks 200 - page 40

    Index IX-II User’s Guide S session establishing 22 using a dialup connection 26 T transparent mode 16 V ventilation 10 viewing port settings 23 ...

メーカー Juniper Networks カテゴリー Switch

Juniper Networks 200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 200の取扱説明書
- Juniper Networksの製品カード
- パンフレット
- またはJuniper Networks 200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Juniper Networks 200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Juniper Networks 200の取り付け説明書、サービスマニュアル、簡易説明書、またはJuniper Networks 200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Juniper Networks 200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Juniper Networks 200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがJuniper Networks 200を使用するのを助ける技術的文書のことです。説明書は通常、全てのJuniper Networks 200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Juniper Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Juniper Networks 200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははJuniper Networks 200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Juniper Networks 200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Juniper Networks 200デバイスの基本機能を使うにあたってのヒント。 Juniper Networks 200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Juniper Networks 200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるJuniper Networks 200のメーカー/サービスへの連絡先に関する情報。

Juniper Networks 200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもJuniper Networks 200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがJuniper Networks 200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)