    PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Models: IG35-NG IG35-LPG IG35-ULPG Owners & Installation Manual 06/23/08 LISTINGS AND CODE APPROV ALS These gas appliances have been tested in accordance with AS4553-2000, NZS 5262 and have been certi fi ed by the Australian Gas Association for installation and opera- tion as described in the ...

  • Regency IG35-NG - page 2

    2 Regency IG35 Gas Inbuilt Fireplace REGENCY GAS INBUIL T FIREPLACE TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The model IG35 of thi ...

  • Regency IG35-NG - page 3

    3 Regency IG35 Gas Inbuilt Fireplace T ABLE OF CONTENTS REGENCY GAS FIREPLACE INSERT DA T A BADGE Data Badge.................................................................... 5 INST ALLA TION Important Message ........................................................ 5 For Y our Safety .............................................................. ...

  • Regency IG35-NG - page 4

    4 Regency IG35 Gas Inbuilt Fireplace DA T A BADGE (Australia Only) This is a copy of the label that accompanies each Regency IG35 Gas Inbuilt fi replace. We have printed a copy of the contents here for your review . DA T A BADGE NOTE: Regency units are con- stantly being improved. Check the label on the unit and if there is a difference, the label ...

  • Regency IG35-NG - page 5

    5 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION IMPORT ANT MESSAGE The Regency Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Note: Failure to follow these instructions could cause a malfunction of the heater which could result in death, serious bodily injury , ...

  • Regency IG35-NG - page 6

    6 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION GAS CONNECTION 3) Locate the center point where the fl ue will pass through the chimney above the appli- ance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level. CAUTION: If the glass is removed for servic- ing, it must be replaced and closed ...

  • Regency IG35-NG - page 7

    7 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION FLUEING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to attach to a 100 mm diameter twin skin or listed gas fuel type fl ue liner running the full length of the chimney . A minimum fl ue height of 1.5 m. is re ...

  • Regency IG35-NG - page 8

    8 Regency IG35 Gas Inbuilt Fireplace TEST FOR FLUE SPILLAGE A " spillage" test must be made before the installed unit is left with the customer . Follow the procedure below: 1) Start all exhaust fans in the home and then close all external doors and windows in the house. 2) Light the unit and set controls to maximum. T urn fan off. 3) Aft ...

  • Regency IG35-NG - page 9

    9 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION Conversion Kit #486-968 for NG to LPG Model THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-968 Contains: Qty . Part # Description 1 904-645 Burner Ori fi ce #51 1 908-528 Red "LPG" label 1 918-590 Label "Converted ...

  • Regency IG35-NG - page 10

    10 Regency IG35 Gas Inbuilt Fireplace 16) T urn on gas supply and plug in power cord. Installer Notice: These instructions must be left with the appliance. 17) Adjusting the Outlet Pressure All the adjustments must be carried out in the following order: Remove the modulator plastic cap (A) using needle nose pliers. Maximum pressure: T urn the unit ...

  • Regency IG35-NG - page 11

    11 Regency IG35 Gas Inbuilt Fireplace Conversion Kit #486-967 for NG to ULPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-967 Contains: Qty . Part # Description 1 904-345 Burner Ori fi ce #53 1 918-273 Red "ULPG" label 1 918-272 Label "Converted to ULPG" 1 91 ...

  • Regency IG35-NG - page 12

    12 Regency IG35 Gas Inbuilt Fireplace 16) T urn on gas supply and plug in power cord. Installer Notice: These instructions must be left with the appliance. 17) Adjusting the Outlet Pressure All the adjustments must be carried out in the following order: Remove the modulator plastic cap (A) using needle nose pliers. Maximum pressure: T urn the unit ...

  • Regency IG35-NG - page 13

    13 Regency IG35 Gas Inbuilt Fireplace The "02" refer numbers (i.e. 02-65) are molded into the rear of each log. 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. 2) Sprinkle the embers on the front, left and right sides of the fi rebox base. LOG SET INST ALLA T ...

  • Regency IG35-NG - page 14

    14 Regency IG35 Gas Inbuilt Fireplace Notch E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side V iew G)02-48 E)02-45 F)02-47 11 ) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray . G)02-48 12) T est fi re to ensure prope ...

  • Regency IG35-NG - page 15

    15 Regency IG35 Gas Inbuilt Fireplace Diagram 1 F ACEPLA TE, TRIM & LOUVER INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch. 2) T ake the top faceplate and align the holes in it with the holes in the side panels. Us- ing the screws provided, attach from the top of the panel (the holes in ...

  • Regency IG35-NG - page 16

    16 Regency IG35 Gas Inbuilt Fireplace PREMIUM FLUSH FRONT INST ALLA TION 6) Place the ECS manual control switch key pad on the outside of the opening in the faceplate and the control switch to the inside of the faceplate. Align the holes and secure in place using the 2 bolts, washers, phenolic spacers, split lock washers and nuts. See diagram 3 for ...

  • Regency IG35-NG - page 17

    17 Regency IG35 Gas Inbuilt Fireplace 11 ) Place the cable ties thru the cable tie holders in the heat shield loosely to secure loose wires. Run the CA T5 cable from the unit thru the cable ties on the heat shield and tighten cable ties. Ensure not to overtighten. Cut excess cable tie. See diagram 8. Diagram 8 CA T5 Cable 12) Partially mount the he ...

  • Regency IG35-NG - page 18

    18 Regency IG35 Gas Inbuilt Fireplace Heat Defl ector T ab into T ab Bracket Diagram 1 1 15) Completely mount the faceplate to the unit. .See diagram 13. Diagram 13 Faceplate Installation: 16) Secure the faceplate in place using 2 screws on the left and right side. Diagram 14 shows mounting on right side. Diagram 14 17) Remove the wire harness fro ...

  • Regency IG35-NG - page 19

    19 Regency IG35 Gas Inbuilt Fireplace 19) Carefully lift off the ignition module from the velcro and slightly bring forward. Remove the wire harness connected to the ignition module as shown in diagram 17. Diagram 17 Ignition Module 20) Discard the complete wire harness that was connected to the valve and ignition module. Wire Harness Removed 21) T ...

  • Regency IG35-NG - page 20

    20 Regency IG35 Gas Inbuilt Fireplace 25) Secure all loose wires in the wire clip to the right side of the valve. See diagram 23. Diagram 23 26) Secure the hinge bracket and hinge to the outside of the fi rebox fl ange on the left and right side as shown using 2 screws on each side. See diagram 24. 27) Align the bottom louver hinge tab screw hole ...

  • Regency IG35-NG - page 21

    21 Regency IG35 Gas Inbuilt Fireplace REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty . The remote control kit comes with a hand held transmitter and a wall mounting plate. 1) Choose a convenient location to mount the hand held transmitter , protection from extreme heat is very i ...

  • Regency IG35-NG - page 22

    22 Regency IG35 Gas Inbuilt Fireplace WIRING WITH PREMIUM FLUSH FRONT OPTION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. W ARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock ...

  • Regency IG35-NG - page 23

    23 Regency IG35 Gas Inbuilt Fireplace OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no ...

  • Regency IG35-NG - page 24

    24 Regency IG35 Gas Inbuilt Fireplace COPY OF LIGHTING INSTRUCTION PLA TE OPERA TING INSTRUCTIONS NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are som ...

  • Regency IG35-NG - page 25

    25 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV - ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERA T - ING THE APPLIANCE. CLOTHING OR OTHER FLAM- MABLE MA TERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDER W A TER. IMMEDIA TEL Y CALL AN ...

  • Regency IG35-NG - page 26

    26 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE F AN MAINTENANCE T o Remove Fan: 1) Turn the unit of f and allow it to cool to room temperature, 2) Unplug or disconnect power source to stove. 3) Open the bottom louvre. 4) Remove the ECS harness from the back clip. 5) Remove the 2 screws that secure the fan in place. 6) Pull out the ECS box. NOTE: ...

  • Regency IG35-NG - page 27

    27 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE REMOVING V AL VE TRA Y 1) Unplug or disconnect the power source to the stove. 2) Shut off the gas supply and remove the gas connection from the valve. 3) Remove the top louvre. 4) Remove the safety screen. 5) Remove the screen door . 6) Remove the logs. 7) Remove the brick panels. 8) Remove the rear ...

  • Regency IG35-NG - page 28

    28 Regency IG35 Gas Inbuilt Fireplace P ARTS LIST ELECTRONIC COMPONENTS P ARTS LIST 910-936 910-082 910-088 910-089 910-084 910-527 910-935 910-080 910-521, 910-522, 910-523, 910-525 910-912 910-906 910-083 910-916 910-514 FG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131 IG35 PG36D 910-909 Fan Resistor 910-936 Intermittent Pilot 910-082 Direct Spark Ignit ...

  • Regency IG35-NG - page 29

    29 Regency IG35 Gas Inbuilt Fireplace MAIN ASSEMBL Y Part # Description Part # Description 1) 910-169/P Fan Motor (240 V) 2) 910-714 Power Cord 240 V olts 3) 820-389 Thermodisc Bracket 5) 910-006 T erminal Block 6) * Levelling Bolts 5/16 x 3 Hex Head 948-216 Logo Plate 918-448 Manual 486-904 Brick Panel (Set) 8) * Brick Panel - Back 9) * Brick Pane ...

  • Regency IG35-NG - page 30

    30 Regency IG35 Gas Inbuilt Fireplace P ARTS LIST F ACEPLA TE ASSEMBL Y Part # Description Part # Description 87) 910-140 Fan HI/OFF/LOW Switch 88) 910-246 Burner ON/OFF Switch 486-918 Faceplate & T rim Complete - Regular 91) * Faceplate Side Right - Regular 92) * Faceplate T op - Regular 93) * Faceplate Side Left - Regular T rims Packaged - Re ...

  • Regency IG35-NG - page 31

    31 Regency IG35 Gas Inbuilt Fireplace W ARRANTY Exclusions: This limited Lifetime W arranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- fi ring, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mounta ...

メーカー Regency カテゴリー Fire Pit

Regency IG35-NGのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IG35-NGの取扱説明書
- Regencyの製品カード
- パンフレット
- またはRegency IG35-NGの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Regency IG35-NGの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Regency IG35-NGの取り付け説明書、サービスマニュアル、簡易説明書、またはRegency IG35-NGのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Regency IG35-NGの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Regency IG35-NGデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRegency IG35-NGを使用するのを助ける技術的文書のことです。説明書は通常、全てのRegency IG35-NGユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Regencyの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Regency IG35-NGの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRegency IG35-NGの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Regency IG35-NGに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Regency IG35-NGデバイスの基本機能を使うにあたってのヒント。 Regency IG35-NGのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Regency IG35-NGに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRegency IG35-NGのメーカー/サービスへの連絡先に関する情報。

Regency IG35-NGについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRegency IG35-NGの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRegency IG35-NGで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)