    No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001 ...

  • Toshiba XIDF-038A - page 2

    No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation. C-1 * ...

  • Toshiba XIDF-038A - page 3

    No. MIIXR0002EAC Table of Contents Page 1 INTRODUCT ION ................................................................................................................ 1 1.1 R EFERENCES ..................................................................................................... 1 1.2 D EFINITIONS .......................................... ...

  • Toshiba XIDF-038A - page 4

    No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules ................................................................ 9 8.1.2 Media Storage XA IOD Modules .......................................................................... 9 8.1.3 XA IOD Modules ........................................................................................... ...

  • Toshiba XIDF-038A - page 5

    No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments. It details the DICOM Service Classes, Information Objects, and Application Profiles which are supp ...

  • Toshiba XIDF-038A - page 6

    No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Sy mbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • AE Application Entity • ANSI American National Standards Institute • AP Application Profile • CEN TC251 Comite Europeen de Normalisation - Techn ...

  • Toshiba XIDF-038A - page 7

    No. MIIXR0002EAC 2 Implement ation Model 2.1 Application Data Flow Diagram Transfer of X-r a y Examinat ion DICOM Recording CD-R Medium Review of X-r a y Examinat ion DICOM Reader Legend Applicati on Entity Local Real-W orld Activi ty File-set Creator (FS C) File-set Reader (FS R) Local Relationship Figure 1 2.2 Functional Definitions of AE's ...

  • Toshiba XIDF-038A - page 8

    No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represent s the contents of t he data as recorded. • Displays the ordered list of patient and image identifying information or icon images. • Reads the selected image SOP instance from the CD-R media and displays it on the monitor ...

  • Toshiba XIDF-038A - page 9

    No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination  The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media. STEP-4: Request recording the transferred images onto the CD-R media. 2.3.2.2 ...

  • Toshiba XIDF-038A - page 10

    No. MIIXR0002EAC 3 AE Sp ecifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and t he Media Storage Application Profile. Table 1 A pplication Profile Identifier Real World Activ ity Role SC Option Basic Cardiac X-ray Angiographic Studies on CD-R Me ...

  • Toshiba XIDF-038A - page 11

    No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relev ant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the C ...

  • Toshiba XIDF-038A - page 12

    No. MIIXR0002EAC 5 Extensions, S pecializations, and Privatizations of SOP Classes and T ransfer Synt axes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Tosh iba Service Personnel at the time of installation of the Digital Fluorography S ...

  • Toshiba XIDF-038A - page 13

    No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage 1 DICOM File Meta Information 8.2.1 M File-set Identificat ion Module 8.3.1 M Basic Dire ...

  • Toshiba XIDF-038A - page 14

    No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage 1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equi pment Module 8.5.5 M Image General Image Module 8.5.6 M Image Image Pixel Module 8.5.7 M Image Cont ...

  • Toshiba XIDF-038A - page 15

    No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Alw ays set DICOM Prefix No Tag 1 Alway s set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version ( 0002, 0001) 1 Alway s set (0x0001) Me ...

  • Toshiba XIDF-038A - page 16

    No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Attribute Description Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set Offset of the Last Directory Record of the Root Directory Entity (0004, 1202) 1 Always set File-set Consistency Flag (0004, 1212) 1 Always set Director ...

  • Toshiba XIDF-038A - page 17

    No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag T ype Attribute Description Study Date (0008, 0020) 1 Alway s set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Length=0 when no entry is made Study Instance UID (0020, 000D) 1C Alway s set Study ID (0020, 0010) 1 Always set Accession Number (0008, 0050) 2 Length= ...

  • Toshiba XIDF-038A - page 18

    No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type A ttribute Description Instance Number (0020, 0013) 1 Alway s set Image Type (0008, 0008) 1 Alway s set Image Date (0008, 0023) 3 Alway s set Image Time (0008, 0033) 3 Alway s set Positioner Primary Angle (0018, 1510) 3 Alway s set [degree] Positioner Secondary Angle (0018, 1511) 3 ...

  • Toshiba XIDF-038A - page 19

    No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Attribute Description Patient's Name (0010, 0010) 2 Always set except for urgent patient Patient ID (0010, 0020) 2 Always set Patient's Birth Date (0010, 0030) 2 Length=0 when no entry is made Patient's Sex (0010, 0040) 2 Alwa ...

  • Toshiba XIDF-038A - page 20

    No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Attribute Description Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Alway s set Series Number (0020, 0011) 2 Always set Series Date (0008, 0021) 3 Always set Series Time (0008, 0031) 3 Always set Performing Physician's Name (0 ...

  • Toshiba XIDF-038A - page 21

    No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Attribute Description Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always set ("MONOCHROME2") Rows (0028, 0010) 1 Always set (0x0400 or 0x0200) Columns (0028, 0011) 1 Always set (0x0400 or 0x0200) Bits Allocated (00 ...

  • Toshiba XIDF-038A - page 22

    No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Attribute Description Frame Increment Pointer (0028, 0009) 1C Always set (0x00181063) Image Type (0008, 0008) 1 Alw ays set Pixel Intensity Relationship (0028, 1040) 1 Alway s set ("DISP" or "LIN") Samples per Pixel (0028, 0002) 1 Always set (0x0001) Pho ...

  • Toshiba XIDF-038A - page 23

    No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification Factor (0018,1114) 3 Alway s set Positioner Motion (0018, 1500) 2C Always set ("STATIC") Positioner Primary Angle (0018, 1510) 2 Always set [deg ...

メーカー Toshiba カテゴリー Portable Media Storage

Toshiba XIDF-038Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XIDF-038Aの取扱説明書
- Toshibaの製品カード
- パンフレット
- またはToshiba XIDF-038Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Toshiba XIDF-038Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Toshiba XIDF-038Aの取り付け説明書、サービスマニュアル、簡易説明書、またはToshiba XIDF-038Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Toshiba XIDF-038Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Toshiba XIDF-038Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがToshiba XIDF-038Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのToshiba XIDF-038Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Toshibaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Toshiba XIDF-038Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははToshiba XIDF-038Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Toshiba XIDF-038Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Toshiba XIDF-038Aデバイスの基本機能を使うにあたってのヒント。 Toshiba XIDF-038Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Toshiba XIDF-038Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるToshiba XIDF-038Aのメーカー/サービスへの連絡先に関する情報。

Toshiba XIDF-038Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもToshiba XIDF-038Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがToshiba XIDF-038Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)