    User Guide 1 Φ /3 Φ 1000 Amp True RMS Power Clamp-On Model 380976 ...

  • HP Extech 380976 - page 2

    380976 V3.2 4/11 2 Introduction Congratulations on your purchase of the Ext ech 380976 Power Cla mp-On Meter. This device measures 1 Φ /3 Φ Power (True, Ap parent, and Reactive), Horsepo wer, Phase Angle, True RMS Current/Voltage, Resistance, Capacitance, Freque ncy, & Temperature. Power meas urements can be achieved on 3- or 4-wire config ur ...

  • HP Extech 380976 - page 3

    380976 V3.2 4/11 3 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for on e year from date of shipment (a six month limited warranty applies to sensors and cables). If it should bec om e necessary to return the instrument for service during or beyond the warranty period, contact the Cu ...

  • HP Extech 380976 - page 4

    380976 V3.2 4/11 4 Meter Description 1. Transformer Jaws 2. Jaw opening trigger 3. Data Hold & MX/MN button 4. Function Selector 5. Range button 6. Temperature input jack 7. LCD Display 8. ‘COM’ input jack 9. ‘ V ’ input jack 10. Ω µA input jack ...

  • HP Extech 380976 - page 5

    380976 V3.2 4/11 5 Measurements AC + DC Voltage Measure ments WA R NI NG The maximum input is 600V. Do no attempt vo ltage measurements above this limit. Exceeding this limit could cause electrical sh ock and damage to the meter. 1. Set the rotary switch to the ‘ V’ position. 2. Insert the test leads into the meter’s input jacks. (Black to ? ...

  • HP Extech 380976 - page 6

    380976 V3.2 4/11 6 AC Power Measurements 1 Φ KW, KVA, KV A R, Pow er Factor & Phase Angle Measurement 1. Set the rotary switch to the ‘KW/KVA’ position. 2. Insert the test leads to the meter as follows: Black to ‘COM’ and Red to ‘V’. 3. Connect the black lead to the neutral line. 4. Connect the red lead to the power line and clamp ...

  • HP Extech 380976 - page 7

    380976 V3.2 4/11 7 3 Φ 3-Wire KW, HP, KVA, KVAR, Pow er Factor & Phase Angle Measurement 1. First, measure W RS(L1 L2) (refer to the diagram be low). a. Set the rotary switch to the “ V ”. b. Press and hold the “ HOLD ” key while setting the rotary switch to “KW/KVA”, the 3 φ 3W and W L12 symbols will appear. c. Insert the test le ...

  • HP Extech 380976 - page 8

    380976 V3.2 4/11 8 3. The power clamp will process these tw o sets of data (W L12 , W L23 ), and show the result on the LCD. The W L123 symbol will be shown to indicate 3 φ 3W power. The 3 φ 3W power (in watts) is stored in the meter memory. 4. To read a single data record, press the “ HOLD ” key to select des ired W L12 , W L23 or W L123 dis ...

  • HP Extech 380976 - page 9

    380976 V3.2 4/11 9 NOTE Once a phase is selected as COM, user s can not change this selection in the subsequent measurement. For example, if S (or L2) phase is selected, S (or L2) phase is always connected to t he COM during measurement of W RS (or W L1L2 ) and W TS (or W L3L2 ) in 3 φ 3W unbalanced power. NOTE 1. The "+" sign printed on ...

  • HP Extech 380976 - page 10

    380976 V3.2 4/11 10 3 Φ 4-Wire KW, HP, KVA, KVAR, Pow er Factor & Phase Angle Measurement 1. First, measure W R(L1) (refer to t he diagram below). a. Set the rotary switch to the “ V ” position. b. Press and hold the “ RA NG E ” key while setting the rotary switch to the “KW/KVA” position, the 3 φ 4W and W L1 s ymbols should appea ...

  • HP Extech 380976 - page 11

    380976 V3.2 4/11 11 3. Third, measure W T(L3) (refer t o the diagram that follows the steps below) a. Disconnect the test probe from the phase wher e th e jaws were clamped in the previous measurement. b. Connect the test probe of the V (red) terminal to th e third phase (e.g. T or L3 phase). c. Clamp the phase where the test probe is connected to ...

  • HP Extech 380976 - page 12

    380976 V3.2 4/11 12 4. The power clamp will proce ss these t hree sets of data ( W L1, W L2 W L3 ) and s how the r esult o n the L CD. The WL 123 symbol will be s hown to indic ate the 3 φ 4W power (r efer to di agram) . The 3 φ 4W power value in w atts is now stored in the meter’s memory. 5. To read a s ingle data re cord , use the “ HOLD ? ...

  • HP Extech 380976 - page 13

    380976 V3.2 4/11 13 KW+KVA R, KVA+ θ ( Phase A ngle) or A+V di splays. 6. W 3 φ 4W = W R(L1) + W S(L2) W T(L3) KVA K W KVAR WW W 34 2 34 2 34 φφ φ =+ PF K W KVA W W W 34 34 34 φ φ φ = 7. Set the rotary switch to another position to exit this mode and clear the stored data. NOTE 1. The "+" sign printed on meter must face the power ...

  • HP Extech 380976 - page 14

    380976 V3.2 4/11 14 Capacitance Me asurements 1. Fully discharge the capacitor under test before pro ceeding. 2. Insert the test leads into the input jacks. (Black to ‘COM’ and Red to ‘ ’). 3. Set the rotary switch to the ‘ ’ position. 4. Connect the red and black test leads to the capacitor. For Electrolytic (polarized) capacitor s, co ...

  • HP Extech 380976 - page 15

    380976 V3.2 4/11 15 Meter Control Keys HOLD - MX/MN Ke y Data Hold Function Press this key momentarily to put the meter into Data Hold mode ( HOLD will appear on the LCD). In this mode, the meter freezes the displayed reading. To e xit the Data Hold mode, press the key again (the HOLD icon will sw itch off). Note that the Data Hold mode is not avai ...

  • HP Extech 380976 - page 16

    380976 V3.2 4/11 16 Automatic Sleep Mode and Battery Replacement The Meter is powered by a 9V batt ery. An AUTO SLEEP feature is included to preserve battery life. Note: The Auto Power OFF feature is disabled when the meter is in the MIN/MAX m ode Note: In the sleep mode the met er continues to draw a small amount of battery curr ent. Always turn t ...

  • HP Extech 380976 - page 17

    380976 V3.2 4/11 17 Specifications General Specifi cations Display Dual Display; 4-digit, 10,000 count (0 to 9999) LC D Jaw Opening 1.6” (42mm) Max. Input limit Max. voltage between any terminal and ground : 600Vrms Sampling rate 2.5 times per second (Digital Disp lay); Once every 6 seconds (KW, KVA, and KVAR) Auto Sleep After approx. 30 minutes ...

  • HP Extech 380976 - page 18

    380976 V3.2 4/11 18 Measurement Specific ations Accuracy: ± ( % of rdg + number of digits) from 18 o C to 28 o C (64 o F t o 82 o F) R.H. < 80% AC Current (50 Hz to 400Hz) Tr ue RMS Range Resolution Accuracy (% reading) Sensitivity Overload Protection 99.99A 10mA 0.10A 999.9A 100mA ± ( 2% + 20d) (50, 60Hz) ± (4 % + 20d) (40~400Hz) 1.0A 1000A ...

  • HP Extech 380976 - page 19

    380976 V3.2 4/11 19 M Ω (Resistance) Range Resolution Accuracy Overload Protection 9.999M Ω 1K Ω 99.99M Ω 10K Ω ±(5% + 10 d) 600V Capacitance Range Resolution Accuracy Overload Protection 10.000 μ F 1nF 100.00 μ F 10nF 1000.0 μ F 100nF ±(1.5% + 5 d) 7000 μ F 1 μ F ±(4.5% + 15 d) 600V Diode (Continuity <40mV) Range Resolution Accurac ...

  • HP Extech 380976 - page 20

    380976 V3.2 4/11 20  Support line (781) 890-7440 Technical support: Ex tension 200; E-mail: supp ort@extech.com Repair & Returns: Ex tension 21 0; E-mail: repair@extech.com Product specifications subject to change without notice For the late st version of thi s User Guide, Software updates, and other up-to-the-minute pr oduct information, ...

メーカー HP カテゴリー Power Supply

HP Extech 380976のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Extech 380976の取扱説明書
- HPの製品カード
- パンフレット
- またはHP Extech 380976の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、HP Extech 380976の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、HP Extech 380976の取り付け説明書、サービスマニュアル、簡易説明書、またはHP Extech 380976のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、HP Extech 380976の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

HP Extech 380976デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHP Extech 380976を使用するのを助ける技術的文書のことです。説明書は通常、全てのHP Extech 380976ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

HPの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. HP Extech 380976の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHP Extech 380976の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。HP Extech 380976に関してこのドキュメントで見つけることができる全てのヒントの目次
3. HP Extech 380976デバイスの基本機能を使うにあたってのヒント。 HP Extech 380976のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。HP Extech 380976に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHP Extech 380976のメーカー/サービスへの連絡先に関する情報。

HP Extech 380976についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHP Extech 380976の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHP Extech 380976で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)