Omron NE- C801KDの取扱説明書

26ページ 3.05 mb
ダウンロード

ページに移動 of 26

Summary
  • Omron NE- C801KD - page 1

    Compressor Nebuliser Model NE-C801KD • Instruction Manual • Mode d’em ploi • Gebrauchsanweisu ng • Manuale di ist ruzioni • Manual de instruccion es • Gebruiksaanwijzin g • РУ К ОВОДСТВО ПО ЭКСПЛУ А Т АЦ ИИ TM TM IM-NE- C801S -KDE-03 -11/2011 533289 2-4C NE- C801S -KD E_A _M0 8_1 10318 .p df 12F1 380 EN FR D ...

  • Omron NE- C801KD - page 2

    QUICK MANUAL Please rea d entire m anual before u sing the device. W arning: Clean and d isinfect all the p arts before usi ng them. pag e 1 6 -1 8 1. Adding medication Rotate th e inh alation t op ant i-cloc kwis e to remove. Add the appropr iate amoun t of presc ribed m edica tion. Make s ure the v aporiser hea d is securel y attached to the inha ...

  • Omron NE- C801KD - page 3

    3. Connecting AC adapt er 4. Att aching air tube Attach the air tube t o the ma in unit and to th e nebul iser kit. When do so, tw ist and pu sh it firml y . pa ge 13 5. Applying mask and st arting inhalation Apply t he mas k secu rely . T urn on the p ower t o the main unit. pa ge 14 Insert the powe r plug of AC adapter into th e power connec tor ...

  • Omron NE- C801KD - page 4

    4 Content s Before using the device Introduction ................. ........... ........... ............ ........... ........... ........... ................. ........... . 4 Intended use ................ ........... ........... ............ ........... ........... ........... ................. ........... . 5 Important safe ty instruct ions ....... ...

  • Omron NE- C801KD - page 5

    5 EN Intended use Medical Purpose This prod uct is inten ded to be used for inhalin g med icatio n for resp irat ory di sord ers . Intended Us er • Legally cer tified me dical expert s, such as doctor , nurse and therapi st. • Caregiv er or p atie nt unde r the gu idanc e of quali fied m edica l expert s for ho me tre atment. • The us er shou ...

  • Omron NE- C801KD - page 6

    6 Import ant safety instructio ns Read a ll the informa tion i n the ins tructio n manu al and an y othe r litera ture inc luded in the box befo re usi ng the device. When usi ng an electri cal pr oduct , especia l ly wh en chi ldren a re pres ent, ba sic s afety precauti ons s hould alw ays be followed incl uding the follo wing : W arning: Indicat ...

  • Omron NE- C801KD - page 7

    7 EN Caution: Indicate s a po tentia lly ha zardous s ituati on whic h if n ot avo ided, may result in mino r or moderate injury , or phy sical da mage. (Usage) • Provid e close s upervis ion when this device i s used b y , on, or near c hildren or inval ids. • Mak e sur e tha t th e parts ar e atta ched co rrec tly . • Make su re that the va ...

  • Omron NE- C801KD - page 8

    8 (Risk of electrica l shock ) • Always unplug the AC adapter from the power outl et after use and before cleaning. • Plug th e devi ce in to the a ppropri ate vo lta ge outlet. Do no t overloa d pow er outlet s or use extensio n cord s. • Always remove th e AC a dapter from the de vice aft er use and before cleaning . • Do not m isuse th e ...

  • Omron NE- C801KD - page 9

    9 EN 1. Know your unit Air Filter Cover *Air filter inside Power Connector Compressor (Mai n Unit) Cap Inhalation Air Inlet Inhalation T op V aporiser Head Medication T ank Air T ube Connector Nozzle Rear View Nebuliser Kit Nebuliser Kit Kids Accesso ry (Smile Bear) Kids Access ory (Happy Bunny) Nebuliser Kit Holder Air Tube Plug Air Tube Connector ...

  • Omron NE- C801KD - page 10

    10 1.Know your unit Accesso ries • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • EN FR DE IT ES IM-NE-C801S-KDE-02-5/2011 5332892-4B NL AR RU Compressor Nebuliser Model NE-C801KD TM TM S pare Air Filters × 5 AC adapter S torage Bag Instruction M anua ...

  • Omron NE- C801KD - page 11

    11 EN 2. Prep aring the nebuliser for use W arning: • Clean and d isinfect the nebuliser kit, kids accessory , m ask or mouthp iece before us ing them for the first time af ter purchase. • If the device has not been used for a long period of time, or if more than o ne person uses the same device, clean and disinfect the nebuliser kit, ki ds acc ...

  • Omron NE- C801KD - page 12

    12 2.Preparing th e nebu liser for u se 2.2 Adding medication and assembling the p art s 1. Remove the mas k or mouth piece , kids a ccessor y and ca p from the nebul iser kit . 2. Remove the in halati on top from the m edica tion t ank. 1) Rotate t he inhalation to p anti-c lockwis e. 2) Lift the inha lation top ou t of the medic ation tan k. 3. A ...

  • Omron NE- C801KD - page 13

    13 2.Preparing the ne bulis er for use EN 6. Attach t he cap, kids ac ces sory , mask or mouthpie ce to the nebu liser kit. 1) Atta ch the ca p to the inhal ation air inl et. 2) Atta ch the ki ds ac cess ory to the inhala tion to p. 3) Atta ch the mask or mouthp iece to the i nhala tion top. Not e: I f the amount of aerosol is t oo small, it is not ...

  • Omron NE- C801KD - page 14

    14 3. T aking medication 1. Hold the nebul iser kit a s indica ted on the rig ht. Cautio n: Do not tilt the nebuliser kit so that it is at an angle of greater than 45° in all directions. Medication may flow into the mouth or it may r esult in not neb ulising effectively . 2. Press the p ower swit ch to t he on ( ) p ositio n. The comp ressor sta r ...

  • Omron NE- C801KD - page 15

    15 3.Tak ing me dica tion EN 4. When treatm ent is c omplete, t u rn the power of f. Check that there is no condensa tion o r mois ture in the air tub e and unplug the devic e from the power outlet. War ni n g: Condensation ma y occur in the air tube. Do not store the ai r tube while it contains condens ation or mois ture. This coul d result in in ...

  • Omron NE- C801KD - page 16

    16 4. Cleaning and daily disi nfecti ng 4.1 Cleaning Follow ing the cleanin g ins tructio ns af ter ea ch us e will p revent any re maini ng me dication in the t ank fr om drying , result ing in t he device not neb ulisi ng ef fect ively and also for preventi ng infectio ns. W arning: Thoroughly rinse the nebuliser kit, kids accessory , mask or mou ...

  • Omron NE- C801KD - page 17

    17 4.Cle aning a nd dai ly disi nfecti ng EN 4.2 Disinfectin g the nebulising p art s Always clean b efore di sinfe ction. (See Sectio n 4.1 “Cl eaning ”) Always disinfe ct the medic ation t ank, mouthpiec e and other nebu lising part s af ter the last treatment of the day . For appropr iate m ethod of di sinfe cting eac h p art, refe r to p ag ...

  • Omron NE- C801KD - page 18

    18 4.Cleanin g and d aily disin fectin g Use the table below as a guideline to select a m ethod for disinfecting O: applicable ×: not applicable * an example of commercially available disinfect ant. Parts Model Materials Boiling Alcohol Sodium hypochlorite Quatern ary ammonium Chlorhexi- dine Amphoteric surfactant Disinfecting ethanol Milton* (0.1 ...

  • Omron NE- C801KD - page 19

    19 EN 5. Maintenance and storage T o keep your dev ice i n the best condition and p rotect the dev ice f rom damag e follow thes e directio ns: Caution: • Do not leave the device unattended with inf ants or persons who cannot e xpress their c onsent. • Do not subject the device or the p arts to any strong shocks such as dropping the device on t ...

  • Omron NE- C801KD - page 20

    20 6. Changing the air fil ter If the air filter h as ch anged colou r , or has b een used on ave rage fo r more t han 60 days, replace it with a new one . 1. Pull the ai r filter cove r of f the compr essor . 2. Change t he air f ilter . 3. Put the air f ilter c over ba ck in pl ace . Not es: • Use only OMRON air filters designed for this device ...

  • Omron NE- C801KD - page 21

    21 EN 7. T roubleshoo ting Chec k the follow ing if your un it should fail dur in g opera tion . Y o u can als o refe r to the pages of thi s manual for co mplete inst ruction s. Note: If the sugges ted remedy does not solve the problem , do not try to repair the device - no parts of the unit are user serviceable. Return the unit to an authorized O ...

  • Omron NE- C801KD - page 22

    22 8. T echnical dat a Notes: • Subject to technical modification without prior notice. • This OMRON product is produced under the strict quality system of OMRON HEA L THCARE Co., Ltd., Japan. • The device may not work if t he temperature and voltage conditions are different to those defined in the specifications. • Do not use the device wh ...

  • Omron NE- C801KD - page 23

    23 8.Tech nical da ta EN T echnical data for the OMRON NE-C801KD Compressor with the OMRON V .V .T . (Vi rtual V alve T e chnology) Ne buliser kit: Result of c ascade impactor m easurements for particle size** * Measured by OMRON HEAL THCARE Co., Ltd. **Indepe ndentl y measu red by Prof. Dr . Hiroshi T akano, Dep a rtment o f Chemical Engineeri ng ...

  • Omron NE- C801KD - page 24

    24 8.Technica l data Important in formation re garding Electro M agnetic Com patibility (EM C) With the incre ased n umber of electro nic de vice s such a s PC’ s and mobile (cellu lar) tele phones, m edic al devic es in use may be su scep tible t o electrom agnet ic int erferenc e from other dev ices. Electro magnetic interfe rence may re sult i ...

  • Omron NE- C801KD - page 25

    25 EN 9. Optional p art s and accessor ies V .V . T . Nebu li ser Kit N-0 1 & Mo uthp iece Set Model: C801 -NSE T3 Order No.: 951 5573-6 V . V . T . Ne buli se r Kit N-01 & Smil e B ear S et Model: C801-NKKD1 Order N o.: 952 001 1 -1 V .V .T . Ne bulis er K it N-0 1 & Happ y Bunny Se t Model: C801-NKKD2 Order N o.: 9520 012-0 Mo uthp ie ...

  • Omron NE- C801KD - page 26

    26 Made in China Manufa cturer OMRON HEAL THCARE Co., Lt d. 53, Kunot sub o, T erado-cho, Muko, Ky oto, 61 7-0002 JAP AN EU-representative OMRON HEAL THCARE EURO PE B.V . Scorpius 33, 21 32 LR Hoo fddorp, THE NETHER LANDS www .omro n-hea lthc are .com Prod uction f acil ity OMRON (DALIAN) CO., L TD. Dalian, CHINA Subs idiar y OMRON HEAL THCARE UK L ...

メーカー Omron カテゴリー Respiratory Product

Omron NE- C801KDのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NE- C801KDの取扱説明書
- Omronの製品カード
- パンフレット
- またはOmron NE- C801KDの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omron NE- C801KDの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omron NE- C801KDの取り付け説明書、サービスマニュアル、簡易説明書、またはOmron NE- C801KDのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omron NE- C801KDの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omron NE- C801KDデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmron NE- C801KDを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmron NE- C801KDユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omronの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omron NE- C801KDの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmron NE- C801KDの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omron NE- C801KDに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omron NE- C801KDデバイスの基本機能を使うにあたってのヒント。 Omron NE- C801KDのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omron NE- C801KDに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmron NE- C801KDのメーカー/サービスへの連絡先に関する情報。

Omron NE- C801KDについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmron NE- C801KDの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmron NE- C801KDで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)