    OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035- 80749-00 ...

  • Sharp AC880 - page 2

    TA BLE OF CONTENTS A C880 B e f o r e U s i n g t h e A C 8 8 0 ..................... 2 S a f e t y P r e c a u t i o n s .......................... 2 U s i n g t h e A C 8 8 0 ........................... 3 S e t u p .................................... 4 Fill Charge Cylinder ......................... 5 R e c o v e r / R e c y c l e ............... ...

  • Sharp AC880 - page 3

    Page 2 BEFORE USING T HE A C880 Check for any shipping damage. Place a claim with carrier if damage is disc overed. DO NOT USE A DAMA GED UNIT. Complete and retur n the Warr anty Card to ac tivate te chnical s upport ser vice and w arra nty coverage. These general instructions describe normal operation and maintenance situations encount ered with t ...

  • Sharp AC880 - page 4

    Page 3 USIN G T HE A C880 Note: The purpose of this discus sio n is to fa m iliarize the user with t he features and functions of the AC880 Refrigerant Handling Station. The procedures discussed in t his manual assume that the AC880 has been set up in accordance with the figures which are referred to and t hat the AC880 has been connected t o the p ...

  • Sharp AC880 - page 5

    Page 4 SETUP 1 Low Pressure Gauge 7 Oil Charge - High Side 13 Fill Port 2 Keypad 8 Red Hose - High Side 14 Refrigerant Cylinder 3 Power Switch 9 Blue Hose - Low Side 15 Y ellow Hose w/Anti-blowback 4 High Pressure Gauge 10 Oil Charge - Low Side 16 Oil Drain Pressure Switch 5 Display 11 Oil Charge Bottle 17 Oil Drain 6 Attent ion Light 12 High/Low C ...

  • Sharp AC880 - page 6

    Page 5 N N N N N N N N N N N N EXTREMELY IMPOR TA NT N N N N N N N N N N N N Always connect Y ellow Hose (15) to Cylinder (14) first and then connect other end of hose with anti-blowback valve to Fill Port (13) on AC880. WEIGHT = XX.X LB AUTOMA TIC ? # >>>> WEIGHT = XX.X LB FILL CY LIND ER ? # ENTER CHECK HO SES START ? # ENTER WEIGHT = ...

  • Sharp AC880 - page 7

    Page 6 WEIGHT = XX.X LB AUTOMA TIC ? # > WEIGHT = XX.X LB RECYCL E ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER CHECK HO SES START ? # ENTER WEIGHT = XX.X LB COMPRE SSOR ON WEIGHT = XX.X LB COMPRE SSOR OFF AMOUN T RECY CLED = XX.X LB # ENTER DRAIN RE COVERED OIL NOW ! # ENTER * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE ...

  • Sharp AC880 - page 8

    Page 7 DRA IN RECOVERED OIL Oil is separated from the recove re d refrigerant and MUST be removed following EACH Recover/ Recycle procedure to determine the amount (if any ) necessary to add into the A/C Sy stem as follows: Note: The AC880 must be connected to pow er source. Drain Recovered Oil may be done while the AC880 Vacuum Pump is ON. 1. Pres ...

  • Sharp AC880 - page 9

    Page 8 WEIGHT = XX.X LB AUTOMA TIC ? # >> WEIGHT = XX.X LB VACUUM ? # ENTER * A/C HAS PR ESSURE GO TO RECY CLE # ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER START ? # ENTER TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER DEEP ...

  • Sharp AC880 - page 10

    Page 9 WEIGHT = XX.X LB AUTOMA TIC ? # >>> WEIGHT = XX.X LB CHARGE ? # ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER WEIGHT = XX.X LB CHARGI NG CHARG E COMP LETE EVAC HOS ES # ENTER CHA RGE 1. Set up the AC880 and turn t he Main Power Switch ON. 2. ...

  • Sharp AC880 - page 11

    Page 10 WEIGHT = XX.X LB AUTOMA TIC ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER CHECK HO SES START ...

  • Sharp AC880 - page 12

    Page 11 WEIGHT = XX.X LB COMPRE SSOR OFF * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE # TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER WEIGHT = XX.X LB CHARGI NG RECYCL ED=XX.X LB EVAC HOS ES # ENTER DRAIN RE COVERED OIL NOW ! # ENTER A U TO M ATIC (continued) The Display will r ead ...

  • Sharp AC880 - page 13

    Page 12 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # ENTER FILTER H OURS= XX.X HOU RS > TOTAL R ECYC LED= XXXX.X K G > TOTAL C HARG ED= XXXX.X K G > A CCESS ST ORED DA TA 1. Set up the AC880 and t urn the Main Power Switch ON. 2. Using t he Keypad, press the “Up Ar row” key f ive times to displa ...

  • Sharp AC880 - page 14

    Page 13 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # Calibration Switch WEIGHT = XX.X LB CHARGI NG > OVER CH ARGE AMOUNT = X.XX KG # >< ENTER SET OVER CHA RGE A MOUNT 1. Remove the front panel of the AC880. 2. S et u p t he AC880 as sh own on P age 4 and then t urn the Main Power Swit ch ON. Refer t ...

  • Sharp AC880 - page 15

    Page 14 SCHEDULED MA INT ENA NCE DA IL Y... Che ck the oil le vel in t he Vacuum Pump while the pump is running. The Vacuum Pum p Oil Level Sight Glass is visible thr ough a hole in the Lower Rear Panel of the AC880. The oil l evel s hould be at the “half-way” point of the glass. If oil is not visibl e call Technical Support at 800-468-2321 (Ex ...

  • Sharp AC880 - page 16

    Page 15 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 360-81555-00 Manifold Assy 880 120V 2 024-80037-00 Contactor ½ HP (120V) 3NO/1N C 3 024-80066-00 Rocker Swi tch SPDT Visired N on-lig hted 4 360-80369-02 D/P Swi tch R134A 5 360-81195-03 Vacuum Pump Assy JB 6 360-81314-00 Low Pressure Sw itch 3 psig- 15in Hg SPD T 7 360-81221-01 Charging Cylinder ...

  • Sharp AC880 - page 17

    Page 16 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 026-80077-00 Combo Filter 3/8 Fl are (Long) 2 360-81192-00 Compressor Inlet Tube Assy 3 360-81197-00 Accumulator Assy 4 360-81356-01 Compressor Assy 780 120V 5 026-80069-00 Combo Filter 3/8 Fl are (Short) 6 360-81292-00 Solenoid MOV Sub- Assy 120V 7 360-81307-00 High Pressur e Switch 261 Psig SPDT ...

  • Sharp AC880 - page 18

    Page 17 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 024-80040-00 Rocker Swi tch SPDT (on-on) Amber 125V 2 024-80060-01 Circuit Boar d 120V 3 026-80065-03 Gauge 30"-120 Psig 1/4 MFL 3.5" 4 025-80128-00 Lamp Holder w /Clear Bulb 120V 5 025-80127-00 Clear Bulb Bay onet Base 120V 6 025-80131-00 Lens Assy Amber 7 026-80071-03 Gauge 0-500 Psig 1 ...

  • Sharp AC880 - page 19

    Page 18 T ROUBLESHOOTING FILL CYLINDER PROCEDURE 1) The cy linder of new refrigerant should be at ambient temperature or great er for best performance of the Fill Cylinder procedure. Make sure the cy linder was not recently moved from an air-conditi oned storage ro om to a w arm w ork a rea . Place the cylinder on a block of wood if necessary t o e ...

メーカー Sharp カテゴリー Refrigerator

Sharp AC880のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AC880の取扱説明書
- Sharpの製品カード
- パンフレット
- またはSharp AC880の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sharp AC880の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sharp AC880の取り付け説明書、サービスマニュアル、簡易説明書、またはSharp AC880のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sharp AC880の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sharp AC880デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSharp AC880を使用するのを助ける技術的文書のことです。説明書は通常、全てのSharp AC880ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sharpの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sharp AC880の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSharp AC880の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sharp AC880に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sharp AC880デバイスの基本機能を使うにあたってのヒント。 Sharp AC880のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sharp AC880に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSharp AC880のメーカー/サービスへの連絡先に関する情報。

Sharp AC880についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSharp AC880の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSharp AC880で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)