American Dynamics AD1645の取扱説明書

32ページ 0.63 mb
ダウンロード

ページに移動 of 32

Summary
  • American Dynamics AD1645 - page 1

    Model 1645 Receiver Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics model 1645 Receiver. Receivers are designed as the remote control device for operation of a motorized pan/tilt unit and a motorized lens unit. Since camera sites are often a great distance from the op ...

  • American Dynamics AD1645 - page 2

    The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The software/firmware is furnished to the purchaser under a license for use on a single system, and remains the property of Americ ...

  • American Dynamics AD1645 - page 3

    QA303C This product generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the spe ...

  • American Dynamics AD1645 - page 4

    T able of Contents Description............................................................................ 1 Features ................................................................................. 1 Installation ............................................................................ 2 Setup .................................................. ...

  • American Dynamics AD1645 - page 5

    DESCRIPTION The 1645 Receiver is a single channel receiver for control of motorized pan/tilt and lens units used with Matrix Switching Systems. The 1645 is used with the American Dynamics 1237VS or Videor Technical VPT-21 Pan/Tilt unit to control the pan, tilt, zoom, focus, and iris of a single camera, and to control auxiliary functions at a camera ...

  • American Dynamics AD1645 - page 6

    INSTALLATION This installation should be made by a qualified service person and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees and personnel working about the premises, by falling objects, by customers, by building vibration, and by similar causes. Preparation Several user configuration swi ...

  • American Dynamics AD1645 - page 7

    SETUP Camera Number Assignment For individual control of camera Pan/Tilt actions by the Matrix Switching System, a camera number must be associated with each Receiver. A 10-position DIP switch labeled “CAMERA ID” is used to associate a particular camera number with the Receiver. This switch is located on the side panel of the 1645 Receiver (see ...

  • American Dynamics AD1645 - page 8

    SETUP 4 Code Terminal Connector Auxiliary and Preposition Connector CAMERA ID Pan/Tilt and Lens Connector POWER LED CODE LED LENS ADJ Power cord Control Code Receiver Module PCB J6 on Main PCB R3 T1 C44 C43 J7 S5 J6 on Receiver Module PCB J1 S2 S1 K1 K2 S4 BLK WHT S3 OFF ON 1 8 U12 U19 U18 Figure 4 - 1645M (Control Code Series) Connector and Switch ...

  • American Dynamics AD1645 - page 9

    RS-232 Receiver (1645S) Setup In order to receive RS-232 code, the S1 and S2 DIP switches on the RS-232 Receiver Module must be set to the following positions. See Figure 5 below for location of these DIP switches on the 1645S Receiver Module PCB. DIP Sw. 1 2 3 4 5 6 7 8 S1 On On Off Off Off Off Off Off S2 --- Reserved for Future Use --- When the 1 ...

  • American Dynamics AD1645 - page 10

    CONNECTIONS Code Line Connections for Control Code (model 1645M) The Code Terminal Connector, J1, is a 3-position terminal connector located on the side of the unit (see Figure 4, page 4). The terminal is marked W (white code), S (shield), and B (black code). A mating screw-terminal plug is provided for this connector. Use 18 AWG, shielded, 2-wire ...

  • American Dynamics AD1645 - page 11

    Code Line Connections for RS-232 (1645S Series) Matrix Switching Systems, RS-232 keyboards, modems, and other RS-232 compatible devices, are connected to the RS-232 connector of the 1645S. The RS-232 Terminal Connector, J3, is a 6-pin connector located on the side of the 1645S (see Figure 5, page 5). A mating screw-terminal plug is provided for thi ...

  • American Dynamics AD1645 - page 12

    Pan/Tilt and Lens Cable The connection to a Pan/Tilt and a motorized Lens is with a 12-pin connector. This connector (J6) is located on the side of the unit, near the Camera ID DIP switch (see Figures 4 and 5, pages 4 and 5). Table 5 lists the pin designations from the Receiver to the Pan/Tilt and the Lens units, and provides space for the installe ...

  • American Dynamics AD1645 - page 13

    Auxiliary and Preposition Cable The connection of auxiliary equipment and preposition servos is with a 14-pin connector. This connector (J7) is located on the side, near the Code Line Connector (see Figures 4 and 5, pages 4 and 5). Table 8 lists the pin designations from the Receiver to the auxiliaries and the pre-position servos and provides space ...

  • American Dynamics AD1645 - page 14

    OPERATION Powering Up The 1645 Receiver is supplied for the following power sources: 1645M,1645S 120VAC, 50/60Hz 1645MX,1645SX 230VAC, 50/60Hz The 1645 Receivers are shipped with a pendant cord and wall plug for use with an electrical outlet. Plug the cord to the required voltage source according to the model. The green LED labeled “POWER” on t ...

  • American Dynamics AD1645 - page 15

    Appendix ...

  • American Dynamics AD1645 - page 16

    ...

  • American Dynamics AD1645 - page 17

    Camera Identification DIP Switch Settings 0 = Off 1 = On 1645M models, set switch positions 7-10 Off; 1645S models, set the switches in the shaded section of the table Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 1 0 0 0000 2 1 0 0000 3 0 1 0000 4 1 1 0000 5 0 0 1000 6 1 0 1000 7 0 1 1000 8 1 1 1000 9 0 0 0100 1 0 1 0 0100 1 1 0 1 01 ...

  • American Dynamics AD1645 - page 18

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 1 2 9 00 0000 1 3 0 10 0000 1 3 1 01 0000 1 3 2 11 0000 1 3 3 00 1000 1 3 4 10 1000 1 3 5 01 1000 1 3 6 11 1000 1 3 7 00 0100 1 3 8 10 0100 1 3 9 01 0100 1 4 0 11 0100 1 4 1 00 1100 1 4 2 10 1100 1 4 3 01 1100 1 4 4 11 1100 1 4 5 00 0010 1 4 6 10 0010 1 4 7 01 0010 1 4 8 11 0010 1 4 9 00 1 ...

  • American Dynamics AD1645 - page 19

    Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 257 0 0 0 0 0 0 258 1 0 0 0 0 0 259 0 1 0 0 0 0 260 1 1 0 0 0 0 261 0 0 1 0 0 0 262 1 0 1 0 0 0 263 0 1 1 0 0 0 264 1 1 1 0 0 0 265 0 0 0 1 0 0 266 1 0 0 1 0 0 267 0 1 0 1 0 0 268 1 1 0 1 0 0 269 0 0 1 1 0 0 270 1 0 1 1 0 0 271 0 1 1 1 0 0 272 1 1 1 1 0 0 273 0 0 0 0 1 0 274 1 0 0 0 1 0 275 0 1 0 0 ...

  • American Dynamics AD1645 - page 20

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 385 0 0 0 0 0 0 386 1 0 0 0 0 0 387 0 1 0 0 0 0 388 1 1 0 0 0 0 389 0 0 1 0 0 0 390 1 0 1 0 0 0 391 0 1 1 0 0 0 392 1 1 1 0 0 0 393 0 0 0 1 0 0 394 1 0 0 1 0 0 395 0 1 0 1 0 0 396 1 1 0 1 0 0 397 0 0 1 1 0 0 398 1 0 1 1 0 0 399 0 1 1 1 0 0 400 1 1 1 1 0 0 401 0 0 0 0 1 0 402 1 0 0 0 1 0 40 ...

  • American Dynamics AD1645 - page 21

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 5 1 3 0 0000 0 5 1 4 1 0000 0 5 1 5 0 1000 0 5 1 6 1 1000 0 5 1 7 0 0100 0 5 1 8 1 0100 0 5 1 9 0 1100 0 5 2 0 1 1100 0 5 2 1 0 0010 0 5 2 2 1 0010 0 5 2 3 0 1010 0 5 2 4 1 1010 0 5 2 5 0 0110 0 5 2 6 1 0110 0 5 2 7 0 1110 0 5 2 8 1 1110 0 5 2 9 0 0001 0 5 3 0 1 0001 0 5 3 1 0 1001 0 5 3 2 ...

  • American Dynamics AD1645 - page 22

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 641 0 0 0 0 0 0 642 1 0 0 0 0 0 643 0 1 0 0 0 0 644 1 1 0 0 0 0 645 0 0 1 0 0 0 646 1 0 1 0 0 0 647 0 1 1 0 0 0 648 1 1 1 0 0 0 649 0 0 0 1 0 0 650 1 0 0 1 0 0 651 0 1 0 1 0 0 652 1 1 0 1 0 0 653 0 0 1 1 0 0 654 1 0 1 1 0 0 655 0 1 1 1 0 0 656 1 1 1 1 0 0 657 0 0 0 0 1 0 658 1 0 0 0 1 0 65 ...

  • American Dynamics AD1645 - page 23

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 769 0 0 0 0 0 0 770 1 0 0 0 0 0 771 0 1 0 0 0 0 772 1 1 0 0 0 0 773 0 0 1 0 0 0 774 1 0 1 0 0 0 775 0 1 1 0 0 0 776 1 1 1 0 0 0 777 0 0 0 1 0 0 778 1 0 0 1 0 0 779 0 1 0 1 0 0 780 1 1 0 1 0 0 781 0 0 1 1 0 0 782 1 0 1 1 0 0 783 0 1 1 1 0 0 784 1 1 1 1 0 0 785 0 0 0 0 1 0 786 1 0 0 0 1 0 78 ...

  • American Dynamics AD1645 - page 24

    Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 8 9 7 00000 0 8 9 8 10000 0 8 9 9 01000 0 9 0 0 11000 0 9 0 1 00100 0 9 0 2 10100 0 9 0 3 01100 0 9 0 4 11100 0 9 0 5 00010 0 9 0 6 10010 0 9 0 7 01010 0 9 0 8 11010 0 9 0 9 00110 0 9 1 0 10110 0 9 1 1 01110 0 9 1 2 11110 0 9 1 3 00001 0 9 1 4 10001 0 9 1 5 01001 0 9 1 6 11001 0 9 1 7 0010 ...

  • American Dynamics AD1645 - page 25

    TYPICAL SYSTEM CONNECTIONS 1645 to 1237VS Pan/Tilt 1237VS PAN/TILT 1645 RECEIVER 7-Pin 1237VS Connector 123456 7 FOCUS ZOOM IRIS SHIELD + 20 VDC TILT - 20 VDC PAN ALARM 1 ALARM 2 GND COMMON J6 ...

  • American Dynamics AD1645 - page 26

    TYPICAL SYSTEM CONNECTIONS 1645 to 1237VSP Pan/Tilt with Pre-position 1237VSP PAN/TILT AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX2 COM J7 1645 RECEIVER 11-Pin 1237VSP Connector FOCUS ZOOM IRIS SHIELD + 20 VDC TILT - 20 VDC PAN ALARM 1 ALARM 2 GND COMMON J6 A BCDE FG H J K L M ...

  • American Dynamics AD1645 - page 27

    TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091 Code Generator, to 1645M (Control Code) 1645M 2091 1996 ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B ...

  • American Dynamics AD1645 - page 28

    TYPICAL SYSTEM CONNECTIONS 2150 Controller to 1645M (Control Code) MAXIMUM DISTANCE between 1645 and 2150 is 5000 Ft, using shielded, 18 AWG cable 2150 1645M BW S RS232 PORTS 123 KEYBOARDS 2345 CAMERAS ALARMS RELAY 120V 60Hz CODE BWS BWS BWS BWS MONITORS 12345 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3 ...

  • American Dynamics AD1645 - page 29

    TYPICAL SYSTEM CONNECTIONS 1676 Keyboard to 1645S (RS-232 Connection) HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (RCD) GREEN (XMIT) 1645S 4 1676 TP8059 Wall Transformer T + T - R + R - CODE POWER AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX2 COM MAXIMUM DISTANCE between 1645 ...

  • American Dynamics AD1645 - page 30

    TYPICAL SYSTEM CONNECTIONS 1983 Code Converter to 1645S (RS-232 Connection) 1983 PSK 120V 60Hz LINE RS232 PHONE 3 2 1 12 11 10 CODE I/O HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (XMIT) GREEN (RCD) 1645S T + T - R + R - CODE POWER AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX ...

  • American Dynamics AD1645 - page 31

    2091 TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091, to 1645S (RS-232 Connection) 1996 1645S ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S ...

  • American Dynamics AD1645 - page 32

    An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 914-624-7685 8000-2894-01 OP1645B May 1994 Printed in USA SPECIFICATIONS Supply Voltage: 1645M,1645S 120VAC, 50/60 Hz 1645MX,1645SX 230VAC, 50/60 Hz Power: ...

メーカー American Dynamics カテゴリー Receiver

American Dynamics AD1645のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AD1645の取扱説明書
- American Dynamicsの製品カード
- パンフレット
- またはAmerican Dynamics AD1645の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Dynamics AD1645の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Dynamics AD1645の取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Dynamics AD1645のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Dynamics AD1645の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

American Dynamics AD1645デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Dynamics AD1645を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Dynamics AD1645ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Dynamicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Dynamics AD1645の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Dynamics AD1645の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Dynamics AD1645に関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Dynamics AD1645デバイスの基本機能を使うにあたってのヒント。 American Dynamics AD1645のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Dynamics AD1645に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Dynamics AD1645のメーカー/サービスへの連絡先に関する情報。

American Dynamics AD1645についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Dynamics AD1645の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dynamics AD1645で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)