    Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work. READ THESE INSTRUCTIO ...

  • Beckett 24 VDC - page 2

    2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Notice Special Requirements............................................. 3 Speci fi cations ..................................................................... 3 General Information ......................... ...

  • Beckett 24 VDC - page 3

    3 24 Vdc SDC Burner Manual Notice Special Requirements If you discover damage to the burner or controls during unpacking, notify the carrier at once and fi le the appropriate claim. When contacting Beckett for service information — Please record the burner serial number (and have available when calling or writing). Y ou will fi nd the serial nu ...

  • Beckett 24 VDC - page 4

    4 T able 1. Combustion Head Firing Rates Firing Rate GPH (min - max) Head 1.75 - 3.25 F22/F220 2.50 - 5.50 F310 Section: General Information & Nozzle Assembly Maintenance Adequate V oltage Required A low or erratic power supply could result in impaired burner operation, severe delayed ignition or an explosion inside the heat exchanger resulting ...

  • Beckett 24 VDC - page 5

    5 24 Vdc SDC Burner Manual Section: Nozzle Assembly Maintenance Correct Nozzle and Flow Rate Required Incorrect nozzles and fl ow rates could result in impaired combustion, under- fi ring, over- fi ring, sooting, puff-back of hot gases, smoke and potential fi re or asphyxiation hazards. Use only nozzles having the brand, fl ow rate (gph), spra ...

  • Beckett 24 VDC - page 6

    6 Figure 5. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance The Beckett Z gauge (part number Z- 2000) is available to permit checking the F head “Z” dimension without removing the burner . C. Igniter Maintenance The igniter assembly does not require any adjustments beyond making sure the springs and the burner electro ...

  • Beckett 24 VDC - page 7

    7 24 Vdc SDC Burner Manual A. Connect Fuel Lines For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard. B. Fuel Supply Level with or Above Burner Section: Fuel Supply Do Not Install Bypas ...

  • Beckett 24 VDC - page 8

    8 Section: Burner Wiring Explosion, Fire, Scald, & Burn Hazard All heating equipment must have HIGH LIMIT controls to protect against excessive temperature and/or pressure. The control must interrupt electrical power and shutdown the burner , if operating or safety controls fail and cause a runaway condition. Follow the equipment manufacturer ? ...

  • Beckett 24 VDC - page 9

    9 24 Vdc SDC Burner Manual Section: Drive Component Maintenance Driv e Component Maintenance A. Motor , Blower Wheel, & Coupling Replacement The motor will require replacement if the proper voltage is measured at the motor input, and the motor will either not run, or the current draw with a free running pump exceeds 10% of the rated current. T ...

  • Beckett 24 VDC - page 10

    10 Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards. Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is ...

  • Beckett 24 VDC - page 11

    11 24 Vdc SDC Burner Manual Section: Maintain & Service Burner Maintain & Ser vice Bur ner A. Owner ’ s Information Have your equipment inspected at regular intervals by a quali fi ed service agency to assure continued proper operation. The burner should be adjusted using dedicated combustion test equipment. Failure to properly set the b ...

  • Beckett 24 VDC - page 12

    12 T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling. When performing the following troubleshooting steps, we assume that the oil burner motor and ignition transformer operate continuously and the oil solenoid valve, which controls oil fl ow , ...

  • Beckett 24 VDC - page 13

    13 24 Vdc SDC Burner Manual Section: T roubleshooting T able 3. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities. Check the air shutter adjustment. ...

  • Beckett 24 VDC - page 14

    14 R eplacement P ar ts Section: Replacement Parts 21 20 14 15 19 17 16 13 12 10 9 8 4 5 6 7 3 2 1 22 18 11 * ‘ X ’s indicate timing options. Contact Beckett for available part numbers. Illustration # Description Part# 1 DC Motor 22190U 2 Blower Wheel (6-1/4”) 2383U 3 Coupling 2154101 4 Burner Housing 5 Air Band, 10 slot 3819A 6 Air Shutter , ...

  • Beckett 24 VDC - page 15

    15 24 Vdc SDC Burner Manual ...

  • Beckett 24 VDC - page 16

    The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship. T o qualify for warranty bene fi ts, products must be installed by a quali fi ed service ...

メーカー Beckett カテゴリー Burner

Beckett 24 VDCのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 24 VDCの取扱説明書
- Beckettの製品カード
- パンフレット
- またはBeckett 24 VDCの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Beckett 24 VDCの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Beckett 24 VDCの取り付け説明書、サービスマニュアル、簡易説明書、またはBeckett 24 VDCのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Beckett 24 VDCの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Beckett 24 VDCデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBeckett 24 VDCを使用するのを助ける技術的文書のことです。説明書は通常、全てのBeckett 24 VDCユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Beckettの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Beckett 24 VDCの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBeckett 24 VDCの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Beckett 24 VDCに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Beckett 24 VDCデバイスの基本機能を使うにあたってのヒント。 Beckett 24 VDCのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Beckett 24 VDCに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBeckett 24 VDCのメーカー/サービスへの連絡先に関する情報。

Beckett 24 VDCについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBeckett 24 VDCの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBeckett 24 VDCで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)