    UNVENTED (VENT -FREE) GAS LOG HEA T ER OWNER’S OP ER A TION AND IN ST AL LA TION MANUAL Design Dynamics V ent-fr ee Mod els Also De sign-Cer ti fi ed As V ented Dec o ra tive Ap pli anc es Sav e this manual for future reference. WARNING: If the information in this man u al is not followed exactly, a fi re or explosion may result caus ing prop e ...

  • Desa VF-24N-BTB - page 2

    111826-01F For more information, visit www .desatech.com 2 T ABLE OF CONTENTS SAFETY INFORMA TION .............................................................. 2 PRODUCT IDENTIFICA TION ....................................................... 3 OPTIONAL REMO TE CONTROL A CCESSORIES ...................... 4 LOCAL CODES .............................. ...

  • Desa VF-24N-BTB - page 3

    111826-01F For more information, visit www .desatech.com 3 3 SAFETY INFORMA TION Continued PR ODUCT IDENTIFICA TION Figure 1 - Product Identifi cation 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not con vertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside an ...

  • Desa VF-24N-BTB - page 4

    111826-01F For more information, visit www .desatech.com 4 LOCAL CODES Install and use heater with care. Follo w all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFP A 54 *. *A vailable from: American National Standards In sti tute, Inc. 1430 Broadway Ne w Y ork, NY 10018 National Fire ...

  • Desa VF-24N-BTB - page 5

    111826-01F For more information, visit www .desatech.com 5 5 40,000 33,000 73,000 Unusuall y tight construction is de fi ned as construction where: a. walls and ceilings exposed to the outside at mo sphere have a con tin u ous water vapor retarder with a rating of one perm (6 x 10 -11 kg per pa-sec-m 2 ) or less with open ings gasketed or sealed a ...

  • Desa VF-24N-BTB - page 6

    111826-01F For more information, visit www .desatech.com 6 AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air Fr om Inside Building This fresh air would come from an adjoining unconfi ned space. When ventilating to an adjoining unconfi ned space, you must pro vide two permanent open ings: one within 12" of the ce ...

  • Desa VF-24N-BTB - page 7

    111826-01F For more information, visit www .desatech.com 7 7 INST ALLA TION NO TICE: This heater is in tend ed for use as sup ple - men tal heat. Use this heater along with y our pri ma ry heat ing system. Do not in stall this heat er as your pri- ma ry heat source. If you ha ve a central heating system, you ma y run sys tem’ s cir cu lat ing blo ...

  • Desa VF-24N-BTB - page 8

    111826-01F For more information, visit www .desatech.com 8 Carefully follo w the instructions belo w . This will ensure safe in- stal la tion into a masonry , UL127-listed manufactured fi replace, or list ed vent-free fi re box. Minimum Clearances For Side Comb ustible Material, Side W all, and Ceiling A. Clearances from the side of the fi re pl ...

  • Desa VF-24N-BTB - page 9

    111826-01F For more information, visit www .desatech.com 9 9 INST ALLA TION Continued MANTEL CLEARANCES In addition to meeting noncom bus ti ble ma te ri al clearances, you must also meet required clearances between fi replace open ing and mantel shelf. If you do not meet the clear anc es listed below, you will need a hood. Determining Minimum Man ...

  • Desa VF-24N-BTB - page 10

    111826-01F For more information, visit www .desatech.com 10 INST ALLING D AMPER CLAMP A CCESSOR Y FOR VENTED OPERA TION Note: When used as a vented decorativ e, ap pli ance must be installed only in a solid-fuel burning fi replace with a working fl ue and con- structed of noncombustible material. If your heater is a non-thermostatically-controlle ...

  • Desa VF-24N-BTB - page 11

    111826-01F For more information, visit www .desatech.com 11 11 INST ALLA TION Continued INST ALLA TION Installing Heater Assembly (Cont.) Connecting to Gas Supply W ARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pres- sure regulator . W ARNING: A qualifi ed ser vice per son must con- nect heater to g ...

  • Desa VF-24N-BTB - page 12

    111826-01F For more information, visit www .desatech.com 12 INST ALLA TION Continued * Purchase the optional CSA design-cer ti fi ed equipment shutoff v alve from your dealer . See Accessories , page 27. **Minimum inlet pressure for purpose of input adjustment. Figure 13 - Gas Connection (Remote-Ready Models Onl y) Gas Control Pipe Cap T ee Nipple ...

  • Desa VF-24N-BTB - page 13

    111826-01F For more information, visit www .desatech.com 13 13 INST ALLA TION Continued INST ALLA TION Checking Gas Connections (Cont.) Figure 16 - Checking Gas Joints (Natural Gas Onl y) Thermostat Gas V alve or Control V alve Location Equipment Shutoff V alve Propane/LP Supply T ank Thermostat Gas V alve or Control V alve Location Thermostat Gas ...

  • Desa VF-24N-BTB - page 14

    111826-01F For more information, visit www .desatech.com 14 OPERA TING HEA TER OPERA TING HEA TER (REMO TE-READ Y MODELS) For Y our Safety Read Before Lighting Lighting Instructions W ARNING: If you do not f ol low these instructions exactl y , a fi re or ex plo sion may result caus ing prop er ty damage, personal injury or loss of life . A. This ...

  • Desa VF-24N-BTB - page 15

    111826-01F For more information, visit www .desatech.com 15 15 OPERA TING HEA TER (REMO TE-READ Y MODELS) Lighting Instructions (Cont.) T o T urn Off Gas T o Appliance Manual Lighting Procedure Remote Control Operation OPERA TING HEA TER Continued Figure 18 - Control Knob and Ignitor Button Location, Remote Ready Contr olled Remote Control 7. With ...

  • Desa VF-24N-BTB - page 16

    111826-01F For more information, visit www .desatech.com 16 NOTICE: You must light the pilot before using the remote con trol unit. See Lighting In struc tions on pa g e 14. GHRCTB Series Operation: 2a. Press the A UTO/ON/OFF but ton on the hand-held re mote con trol (see Fig ure 21). The lights to the left of the button will show A UTO, ON, or OFF ...

  • Desa VF-24N-BTB - page 17

    111826-01F For more information, visit www .desatech.com 17 17 BURNER FLAME P A TTERN Figure 24 sho ws correct burner fl ame pattern. NO TICE: Do not mistake orang e fl ames with y ellow tipping. Dir t or other fi ne particles are b urned by heat er , causing brief patches of orange fl ame . If burner fl ame pattern is incorrect, as shown in F ...

  • Desa VF-24N-BTB - page 18

    111826-01F For more information, visit www .desatech.com 18 W ARNING: T urn off heater and let cool bef ore cleaning. CA UTION: Y ou must keep contr ol areas, burners, and cir cu lat ing air pas sage ways of heat er clean. In- spect these areas of heater before each use. Have heater inspected yearl y by a qual i fi ed service per- son. Heater may ...

  • Desa VF-24N-BTB - page 19

    111826-01F For more information, visit www .desatech.com 19 19 TR OUBLESHOO TING Note: All troubleshooting items are listed in order of operation. W ARNING: T urn off and un- plug heater and let cool before servicing. Only a qualifi ed ser vice person should service and repair heater . CA UTION: Ne ver use a wire, needle, or similar object to clea ...

  • Desa VF-24N-BTB - page 20

    111826-01F For more information, visit www .desatech.com 20 TR OUBLESHOO TING Continued OBSER VED PR OBLEM One or both burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfi ring dur ing com bus tion Orange flame in burner during b urner com bus tion Slight smoke or odor during initial op- er a tion Heater produces a ...

  • Desa VF-24N-BTB - page 21

    111826-01F For more information, visit www .desatech.com 21 21 TR OUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any ap pli ance . • Do not touch an y elec tri cal switch; do not use any phone in y our build ing. • Immediately call y our gas sup plier from a neighbor’ s phone . Follow the ...

  • Desa VF-24N-BTB - page 22

    111826-01F For more information, visit www .desatech.com 22 VF-18N-PDG/VF-18N-BTB VF-24N-PDG/VF-24N-BTB Btu (V ariable) 24,000/36,000 25,000/39,000 T ype Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Manifold Pressure 3.5" W .C. 3.5" W .C. Inlet Gas Pressure (in. of water) Maximum 10.5" W .C. 10.5" W .C. Minimum* 5. ...

  • Desa VF-24N-BTB - page 23

    111826-01F For more information, visit www .desatech.com 23 23 SER VICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will ha ve delayed ig ni tion • heater will not produce specifi ed heat • propane/LP gas supply may be lo w Y ou may feel your gas pressure is too low . If so, contact your local propane/LP or natu ...

  • Desa VF-24N-BTB - page 24

    111826-01F For more information, visit www .desatech.com 24 GT A Replacement P ar t Numbers Model Number GT A P ar t number VF-18N-PDG 111794 03 VF-18N-BTB VF-18P-PDG 111794 04 VF-18P-BTB Log sets and mounting plates are ordered as an assembly REMO TE MODELS ONL Y ILLUSTRA TED P AR TS BREAKDO WN REMO TE-READ Y MODELS AND REMO TE CONTROLLED MODELS V ...

  • Desa VF-24N-BTB - page 25

    111826-01F For more information, visit www .desatech.com 25 25 ILLUSTRA TED P AR TS BREAKDO WN REMO TE-READ Y MODELS AND REMO TE CONTROLLED MODELS VF-24N-PDG VF-24N-BTB VF-24P-PDG VF-24P-BTB ILLUSTRA TED P AR TS BREAKDOWN VF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB 3 Log sets and mounting plates are ordered as an assembly REMO TE MODELS ONL Y GT ...

  • Desa VF-24N-BTB - page 26

    111826-01F For more information, visit www .desatech.com 26 P AR TS LIST This list contains replaceable parts used in your heater . When order - ing parts, follo w the instructions listed under Replacement P arts on page 23 of this manual. P AR TS LIST VF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB, VF-18N-PDG, VF-18P-PDG, VF-18N-BTB, VF-18P-BTB P ...

  • Desa VF-24N-BTB - page 27

    111826-01F For more information, visit www .desatech.com 27 27 A CCESSORIES W ALL-MOUNT THERMOST A T SWITCH - GWMT1 (Not Shown) F or all Remote-Ready Models. The desired com fort setting can be selected on the wall ther mo stat and the log heat er will au to mat i cal ly cycle from pi lot to the heat setting selected. W ALL-MOUNT ON/OFF SWITCH - GW ...

  • Desa VF-24N-BTB - page 28

    111826-01F For more information, visit www .desatech.com 28 THIS P A GE INTENTIONALL Y LEFT BLANK ...

  • Desa VF-24N-BTB - page 29

    111826-01F For more information, visit www .desatech.com 29 29 • A CCESSORIES 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/Warehouse ❍ Utility Shed/Outb uilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product y ourself, did you plan to purchase this type of product bef ore going into the stor ...

  • Desa VF-24N-BTB - page 30

    111826-01F For more information, visit www .desatech.com 30 2701 S. Harbor Blvd. Santa Ana, CA. 92704 www .desatech.com P ost age Required TM ...

  • Desa VF-24N-BTB - page 31

    111826-01F For more information, visit www .desatech.com 31 31 NO TES ________________________________________________________________________________________________ ________________________________________________________________________________________________ ______________________________________________________________________________________ ...

  • Desa VF-24N-BTB - page 32

    111826-01F For more information, visit www .desatech.com 32 2701 S. Harbor Blvd. Santa Ana, CA. 92704 www .desatech.com 111826-01 Re v . F 03/05 NO T A UPC KEEP THIS W ARRANTY W ARRANTY INFORMA TION Model Serial No . Date Purchased Always specify model and serial numbers when communicating with the f actory . W e reserve the right to amend these sp ...

メーカー Desa カテゴリー Gas Heater

Desa VF-24N-BTBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VF-24N-BTBの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa VF-24N-BTBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa VF-24N-BTBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa VF-24N-BTBの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa VF-24N-BTBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa VF-24N-BTBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa VF-24N-BTBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa VF-24N-BTBを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa VF-24N-BTBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa VF-24N-BTBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa VF-24N-BTBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa VF-24N-BTBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa VF-24N-BTBデバイスの基本機能を使うにあたってのヒント。 Desa VF-24N-BTBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa VF-24N-BTBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa VF-24N-BTBのメーカー/サービスへの連絡先に関する情報。

Desa VF-24N-BTBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa VF-24N-BTBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa VF-24N-BTBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)