APC 230 Vacの取扱説明書

18ページ 0.32 mb
ダウンロード

ページに移動 of 18

Summary
  • APC 230 Vac - page 1

    Operation Manual Smart-UPS ® Uninterruptible Power Supply 750/1000/1500/2200/3000 V A T ower 100/120/230 V ac 500 V A T ower 100 V ac ...

  • APC 230 Vac - page 2

    ...

  • APC 230 Vac - page 3

    1 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 500 V A to 3000 V A T ower is a high perform ance uninterruptible power supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and surges, sm ...

  • APC 230 Vac - page 4

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 2 Product Overview Front p anel features Rear p a nel features 500 V A to 15 00 V A models  Display interface 500/750/1000/1 500 V A 2200/3000 V A  Bezel  Battery  Internal battery connector  USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A 230 V ac  ...

  • APC 230 Vac - page 5

    3 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Rear p a nel features 2200 V A and 30 00 V A models Inst allation For UPS installation information, refer to the Smart-UPS Installati on Guide 750/10 00/1500/2200/300 0 V A 100/120/230 V ac, 500 V A 100 V ac T ower, that is included with the UPS. The Installation guide i ...

  • APC 230 Vac - page 6

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 4 Operation Connect Equipment Note: The UPS will char ge to 90% capacity in th e first four and a half hours of normal operation for the 2200/3000 V A 100 V ac model or the first three hours of normal operation for all other models . Do not expect full battery runtime capabi ...

  • APC 230 Vac - page 7

    5 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Display Panel Using the display interface Use the U P and D OWN keys to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. St andard menus The Standard menus a ...

  • APC 230 Vac - page 8

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Menu General Functions St a t u s V iew detailed UPS information: • Operating Mode • Effic iency • Load ...

  • APC 230 Vac - page 9

    7 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the di splay interface. As an a lternative, configuration can be performed using APC PowerChute ® software. Note: During start-up, use the display interface to configure th ...

  • APC 230 Vac - page 10

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 8 Low T ransfer Point 100 V ac: 92 V ac 86 V ac - 92 V ac Set the transfer point lower if the utili ty volt age is chronically low and the connected equipment can tolerate this cond iti on.T his setting may also be ad juste d using the power quality setting. Note: Use the Ad ...

  • APC 230 Vac - page 11

    9 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Main Outlet Group and Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be configured to independently turn of f, turn on, shut down, and reboot connecte d equipment. (These features are not available on the 500 V A or 750 V A units. ...

  • APC 230 Vac - page 12

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 10 Customize the Main and Switched Outlet Groups Use the Configuration menus to change the Main Outlet Gro up and the Switched Ou tlet Group settings. Network Management Card Settings These settings are available only on units that have a Ne twork Management Card (NMC) and a ...

  • APC 230 Vac - page 13

    11 Smart-UPS 750/1000/1 500/22 00/3000 VA 1 00/120/2 30 Vac 50 0 VA 100 Vac Tower Emergency Power Off Overview The Emergency Power Off (EPO) optio n, is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . Adhere to all national and ...

  • APC 230 Vac - page 14

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 12 T r oubleshooting Prob lem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the ON key once to turn on the UPS. The UPS is not connected to utility power . Be sure the power cabl e is securely connected to ...

  • APC 230 Vac - page 15

    13 Smart-UPS 750/1000/1 500/22 00/3000 VA 1 00/120/2 30 Vac 50 0 VA 100 Vac Tower Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r ou bleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .a ...

  • APC 230 Vac - page 16

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 14 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from dat ...

  • APC 230 Vac - page 17

    ...

  • APC 230 Vac - page 18

    2/2012 990-3534C APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow i ng ways: • V isit the APC W e b site to acce ss docume nts in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb ...

メーカー APC カテゴリー Power Supply

APC 230 Vacのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 230 Vacの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC 230 Vacの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC 230 Vacの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC 230 Vacの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC 230 Vacのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC 230 Vacの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC 230 Vacデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC 230 Vacを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC 230 Vacユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC 230 Vacの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC 230 Vacの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC 230 Vacに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC 230 Vacデバイスの基本機能を使うにあたってのヒント。 APC 230 Vacのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC 230 Vacに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC 230 Vacのメーカー/サービスへの連絡先に関する情報。

APC 230 Vacについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC 230 Vacの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC 230 Vacで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)