Newcon Optik NEWCON LRB 3000 PROの取扱説明書

14ページ 0.28 mb
ダウンロード

ページに移動 of 14

Summary
  • Newcon Optik NEWCON LRB 3000 PRO - page 1

    Newcon International ltd. © 2005-2006 Printed in Canada Operation Manual LRB 3000PRO LASER RANGE FINDER BINOCULAR In USA: 2331 Superior Ave. Cleveland, OH 44114 In Canada: 105 Sparks Ave., Toronto, ON M2H 2S5 ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 2

    IMPORTANT INFORMATION Read prior to activation You have just purchased a complicated electronic device, which emits invisible laser radiation. To operate it properly, please read this manual carefully. Here are some common precautions that must be noted. • NEVER direct laser radiation at th e eyes of people or animals • NEVER stare into direct, ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 3

    9. CUSTOMER SUPPORT Should you experience any difficulties with your Newcon Optik product, please consult the enclosed manual. If the problem remains unresolved, contact our customer support department at +1-416-663-6963 or toll free in North America at 1-877-368-6666. Our operating hours are 9am-5pm, Monday - Friday, Eastern Standard Time. At no t ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 4

    TABLE OF CONTENTS 1. Brief description 2. Appearance of the device 3. Supplied accessories 4. Technical characteristics 5. Operation instructions 5.1. Preparing the device for operation 5.2. Measuring procedure 5.3. Mode switching procedure 5.4. Additional display information 5.5. Test modes 6. Storage and maintenance instructions 7. Troubleshootin ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 5

    7. TROUBLESHOOTING The range-measuring mode does not work. The display is transparent. Check whether the battery is installed properly. Check the charge of the battery. Replace it if it is weak The range-measuring mode temporarily does not work. The display indicates results of the last measurement or transparent. Wait for 8 seconds, and press the ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 6

    2. APPEARANCE OF THE DEVICE 1 – Eyepieces; 2 – Objective lens; 3 – Mode button; 4 – Action ( * ) button; 5 – Bat tery compartm ent cover; 6 – Rubber grip Fig. 1 6 6. STORAGE AND MAINTENANCE INSTRUCTIONS . Precautions: LRB 3000Pro is a sophisticated precision optical instrument equipped with electronics. Therefore, it should be handled w ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 7

    voltage of the primary 9-Volt battery drops below 7.2 Volts. At this point the System is still functional but the battery should be replaced as soon as possible. The System can operate at the voltage level above 7 Volt. The System remains in the active displaying state for 8 seconds after pressing of any of the operating buttons and after 8 seconds ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 8

    4. TECHNICAL CHARACTERISTICS 1. Optics Magnification, x Objective lens diameter, mm Exit pupil diameter, mm Field of view Type of coating 7 40 5.7 6 ° Fully multi-coated glass optics 2. Range Finder Type Measuring range, m Accuracy, m First, last and auto target acquisition Meters/Yards display Last 10 readings recall Reticle shape Target quality ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 9

    5.4. Additional display information The System operates in the setting Modes that are displayed as follows (refer to Fig.3): Y/M – units of distance measurement: yards or meters (3). KMH/MPH – units of speed measurement: km/hour or miles/hour (3). ° - units of angular measurement: degrees (3) Shape of the reticle: cross shape or rectangular sh ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 10

    5.1. Preparing the device for operation. • Rotate counterclockwise and open the battery compartment cover (5) located between the objective lenses (fig. 1). • Insert one 9V Ni-MH battery into the battery compartment observing correct polarity. • Close the battery compartment cover (5). • Adjust the interpupillary distance with lever (7) (fi ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 11

    • Cd12 – this mode sets the target selection to First. No other parameters of those, which were previously set, are influenced. • Cd13 – this mode sets the target selection to Auto. No other parameters of those, which were previously set, are influenced. • Cd14 KMH – the unit will measure and display two parameters at once as distance i ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 12

    behind bushes, wires, flakes, or, opposite, measure a distance to wire, which hangs in front of the building wall. However, it cannot be guaranteed that the device will always measure the needed distance. It can happen that there will be no pulses bounced off the desired object at all. 5.3. Mode switching procedure By pressing Mode ( M ) button (3) ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 13

    If you want to leave the mode switching procedure without remembering your choice, you should press and keep held the M button for more than two seconds. This works like “Escape” key on a computer keyboard. The rangefinder will remain in the last set mode and return to the READY state. Below is the full list of all modes available in the main m ...

  • Newcon Optik NEWCON LRB 3000 PRO - page 14

    M od e Screen dis pla y 1) Sta ndard 1 M A ,,, Met er D egree Code s 2) A M Go into submen u Code 1 A M Met e r Code 2 A M Ya rd Code 3 A M Deg r e e Code 8 A M Code 9 A M Deg r e e Code 10 A M Ya rd Not used Not used Not use d Not used Aut o Ta rg et Aut o Targ et Go t o nex t mode Go to n ext mo d e Go t o nex t mode Go to next mod e Go to next m ...

メーカー Newcon Optik カテゴリー Binoculars

Newcon Optik NEWCON LRB 3000 PROのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NEWCON LRB 3000 PROの取扱説明書
- Newcon Optikの製品カード
- パンフレット
- またはNewcon Optik NEWCON LRB 3000 PROの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Newcon Optik NEWCON LRB 3000 PROの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Newcon Optik NEWCON LRB 3000 PROの取り付け説明書、サービスマニュアル、簡易説明書、またはNewcon Optik NEWCON LRB 3000 PROのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Newcon Optik NEWCON LRB 3000 PROの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Newcon Optik NEWCON LRB 3000 PROデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNewcon Optik NEWCON LRB 3000 PROを使用するのを助ける技術的文書のことです。説明書は通常、全てのNewcon Optik NEWCON LRB 3000 PROユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Newcon Optikの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Newcon Optik NEWCON LRB 3000 PROの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNewcon Optik NEWCON LRB 3000 PROの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Newcon Optik NEWCON LRB 3000 PROに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Newcon Optik NEWCON LRB 3000 PROデバイスの基本機能を使うにあたってのヒント。 Newcon Optik NEWCON LRB 3000 PROのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Newcon Optik NEWCON LRB 3000 PROに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNewcon Optik NEWCON LRB 3000 PROのメーカー/サービスへの連絡先に関する情報。

Newcon Optik NEWCON LRB 3000 PROについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNewcon Optik NEWCON LRB 3000 PROの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNewcon Optik NEWCON LRB 3000 PROで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)