    Owner’ s Manual Model: X11 For T echnical Assistance, please call (800) 638-3600, or visit www .magnadyne.com ...

  • Magnadyne X11 - page 2

    T able of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Remote Control T ransmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Magnadyne X11 - page 3

    3 2-Way LCD Remote 1-Way Backup Remote HOOD TRUNK ARM IGN 2-Way LCD Remote LCD Display Icons Congratulations on your purchase of a quality Marksman automotive security and remote start system. Marksman security products have been designed to provide the consumer with a technologically superior product with years of trouble free operation. The infor ...

  • Magnadyne X11 - page 4

    T ransmitter Button System Function Remark Locks Doors & Arms System Arm and Bypass the 2 Stage Shock Sensor (Zone 4) Press Twice within 3 Seconds Silent Arming/Disarming Ignition in “OFF” Position Active Anti-Car Jacking Mode Ignition in “ON” Position, Press and Hold for 2 Seconds - + + - Arm and Bypass the 2nd Sensor (Zone 6) Press wi ...

  • Magnadyne X11 - page 5

    5 Flash Function 1 Flash System is Armed 2 Flashes System is Disarmed 3 Flashes Disarmed / T riggered 2 - 3 - 6 Flashes Car Locator Constant On Engine Running Under Remote Start (Default Setting) Chirp Function 1 Chirp System is Armed 2 Chirps System is Disarmed 3 Chirps Defective Sensor of Open Door Reminder 4 Chirps Disarm / Previously T riggered ...

  • Magnadyne X11 - page 6

    Siren/Horn Parking Light LED Doors Starter Dome Light 1. Arming 1 or 3 Chirps 1 Flash Slow Flash Locking Disabled 2. Disarming 2 to 4 Chirps 2 or 3 Flashes Unlocking T urns on for 30 Seconds 3. T rigger Alarming Flashing Pause Flash Disabled Flashes 4. Panic Alarming Flashing Flashes 5. Car Jacking Alarming Flashing Disabled Flashes LED Function OF ...

  • Magnadyne X11 - page 7

    If the siren sounds 3 times, there is a Door , T runk, or Hood left open. Pressing the transmitter and button at the same time will arm or disarm your security system, No chirp sound will be heard, arm/disarm confirmation will be through the vehicles parking lights only . Press the button on the transmitter two times within 3 seconds. This will arm ...

  • Magnadyne X11 - page 8

    System Disarmed Door T riggered T runk/Hood T riggered HOOD TRUNK IGN Shock Sensor T riggered Ignition T riggered (Additional programming required) The vehicle doors will automatically lock after the automatic arming cycle has been completed. While the system is in disarmed mode, press the button twice. The horn/siren will respond with one chirp an ...

  • Magnadyne X11 - page 9

    (Additional Wiring Required) This feature will independently unlock the drivers door only when disarming the security system. Pushing the button a second time within 3 seconds will unlock the other doors. (Must be Programmed On) If this feature is selected, the security system will automatically rearm itself within 60 seconds after disarming with t ...

  • Magnadyne X11 - page 10

    Note: The remote vehicle location system is active 30 seconds after the alarm is armed. 1. Press the button to active the vehicle locator system. The horn/siren will beep 2 times and the parking lights will flash 3 times. This operation will repeat a second time. 2. Press the button again within 30 seconds. The horn/siren will beep 3 times and the ...

  • Magnadyne X11 - page 11

    When the Security System is triggered, it will alert the user with flashing icons on the LCD Display and audible melody sound. T o stop the melody sound, press any button on the LCD transmitter . When the Security System is triggered, the LCD screen will alert the user through melody sound and flashing icons. By pressing the “SET” button 3 time ...

  • Magnadyne X11 - page 12

    Three Timer cir cuits will function as follows: First Timer Circuit 1. 50 seconds after the car jacking mode has been activated, the siren will begin to sound for 15 seconds. 2. During the 15 second activation period, you will be alerted to push the valet switch once to turn off the car jacking feature. 3. If by now the valet switch has not been pu ...

  • Magnadyne X11 - page 13

    It is useful in the event that someone wants to page the driver of the parked vehicle. (Optional) With the ignition switch in the "OFF" position, press the valet switch for 2 seconds to page the driver . One chirp will sound from the vehicle and the LCD transmitter will begin to sound with a melody . The icon will then appear on the LCD t ...

  • Magnadyne X11 - page 14

    Press and hold the and button at the same time to activate the Channel 5 output. Press and hold the and button at the same time to activate the Channel 6 output. Press and hold the and button at the same time to activate the Channel 7 output. Not e: If Channel 7 has been programmed for defrost operation it will not function from the transmitter . C ...

  • Magnadyne X11 - page 15

    1. Press the button twice on the remote transmitter . 2. The parking lights will turn “ON” to indicate the remote start command has been received. 3. The engine will start in approximately 5 seconds. 4. Once the engine is running, the parking lights will turn back on to indicate climate controls are activated to your presettings (While the vehi ...

  • Magnadyne X11 - page 16

    16 This feature allows the vehicle to remain running after the key has been removed from the ignition. This feature is useful for occasions when you wish to exit and lock/arm the vehicle for short periods of time. This will keep the engine running for climate controls to stay on. 1. Before turning the engine off with the ignition key, press the but ...

  • Magnadyne X11 - page 17

    Note: The transmission range may become shorter if the system is interfered by a stronger radio frequency from sources of high voltage electric power or obstacles like tall buildings. The transmitter uses low output powered frequency . T urbo Timer Mode keeps the engine running after arriving at you destination for a programmable time period of 3, ...

  • Magnadyne X11 - page 18

    18 Remote LCD Icons Armed Mode Vehicle is in armed mode Car Jack Mode Car jacking mode is activated Hood T rigger Hood is illegally opened (Zone 1) T runk T rigger T runk is illegally opened (Zone 2) System T rigger Time Monitor Melody Mode Remote control alert user through melody sound Channel #6 is Activated Channel #7 is Activated Channel #5 is ...

  • Magnadyne X11 - page 19

    Button Description Operation SET LCD Screen Lamp T urns ON for Press and Hold for 1 Second Five Seconds 1 Melody Sounds to Confirm SET Timer Programming Mode Press and Hold for 3 Seconds 2 Melody Sounds to Confirm SET Power Save Mode Press and Hold for 5 Seconds 1 Melody Sounds to Confirm SET (3X) Clear the Flash Icon and Melody Sound Press within ...

  • Magnadyne X11 - page 20

    20 While triggering the alarm, the LCD screen will alert the user through melody sound and flashing trigger icon. Press any button on the transmitter to stop melody sound only . Use this mode to disable the transmission function of the remote control temporarily to prevent any inadvertent pressing of buttons. 1. Press the “SET” button first, wi ...

  • Magnadyne X11 - page 21

    Step Button Description Operation 1 Press and Hold SET Button for 3 Seconds Time Setting (Hour) Flash Digit for Adjusting for (-) and (+) 2 Press the SET Button Once Time Setting (Min.) Flash Digit for Adjusting for (-) and (+) 3 Press the SET Button Once Alert Alarm Time Setting (Hour) Flash Digit for Adjusting for (-) and (+) 4 Press the SET Butt ...

  • Magnadyne X11 - page 22

    Replacement Parts 4-Button Transmitter for X11 Security System X1 1RF 59.95 ea. 5-Button Transmitter for X11 Security System X11 RF- LCD $139.95 ea. TRANSMITTERS DESCRIPTION MODEL # PRICE BATTERIES **1.5 Volt AAA Lithium Battery Highly Recommended *1.5 Volt AAA High Capacity Digital Camera Battery Suggested 1.5 Volt AAA Alkaline Battery Minimum CR2 ...

  • Magnadyne X11 - page 23

    Parts Order Form Credit Card or Money Order Only (Sorry No Cash, C.O.D. or personal checks accepted) SHIP TO: (No P .O. Boxes) LAST NAME FIRST NAME INITIAL STREET ADDRESS ADDITIONAL ADDRESS ADDITIONAL ADDRESS CITY ST A TE ZIP CODE DA Y TIME PHONE NUMBER PAR T # DESCRIPTION QTY . PRICE EACH TOTAL Sales Subtotal = ________ . ______ California Residen ...

  • Magnadyne X11 - page 24

    X11-UM 3-5-08 Rev. A © Copyright 2008 Magnadyne Corporation Limited Lifetime Warranty Magnadyne Corporation or its authorized agents will, for the life of the vehicle and to the original purchaser , repair , replace or refund the retail sales price of said product or any part thereof, at the option of the Magnadyne Corporation or its authorized ag ...

メーカー Magnadyne カテゴリー Remote Starter

Magnadyne X11のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- X11の取扱説明書
- Magnadyneの製品カード
- パンフレット
- またはMagnadyne X11の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Magnadyne X11の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Magnadyne X11の取り付け説明書、サービスマニュアル、簡易説明書、またはMagnadyne X11のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Magnadyne X11の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Magnadyne X11デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMagnadyne X11を使用するのを助ける技術的文書のことです。説明書は通常、全てのMagnadyne X11ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Magnadyneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Magnadyne X11の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMagnadyne X11の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Magnadyne X11に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Magnadyne X11デバイスの基本機能を使うにあたってのヒント。 Magnadyne X11のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Magnadyne X11に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMagnadyne X11のメーカー/サービスへの連絡先に関する情報。

Magnadyne X11についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMagnadyne X11の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMagnadyne X11で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)