    990-3485B 01/2009 Smart-UPS ® RC Uninterruptible Power Supply T ower/Rack-Mount 4U XLI/XLICH/XLI-CC SRC1000/2000/3000 V A 220/230/240 V ac English ...

  • APC Smart-UPS RC 2000VA - page 2

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 3 Introduction Overview The American Power Conversion (APC ® ) Smart-UPS ® RC is a high performance uninterruptible power supply (UPS) that provides protection fo r electronic equipment from utility power blackou ts, brownouts, sags and surges. The U ...

  • APC Smart-UPS RC 2000VA - page 3

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 4 Specifications Environment al Specifications Physical Specifications T emperature Operating 0° to 40° C (32° to 104° F) This unit is intended for indoor use only . Select a locati on sturdy enough to handle the weight. Do not operate UPS where the ...

  • APC Smart-UPS RC 2000VA - page 4

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 5 Front and rear p anels Rear panel Features The input circuit breaker protects th e UPS from extreme overload cond itions. Serial port for: • Power management software • Interface kits Use only interface kits supplied or appr oved by APC. Any othe ...

  • APC Smart-UPS RC 2000VA - page 5

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 6 Inst allation Units may vary in appear ance fro m those depicted in this manual. Always place UPS above XLBPs in rack-mount configuration. Connect all battery string s. Failure to do so may cause eq uipment damage. Refer to Physical Specification s in ...

  • APC Smart-UPS RC 2000VA - page 6

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 7 Output hardwire instructions Adher e to all nation al an d local electrical codes. Wiring must be performed by a qualified electrician. • Use 1.3 mm 2 (#16 A WG) wire (not suppl ied) • Maximum o utput rating: 220-240 V , 50 -60 Hz, 10 A 1. Locate ...

  • APC Smart-UPS RC 2000VA - page 7

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 8 Inst all and conne ct batterie s This unit is equipped with battery modules. Each module must be connected to battery connectors on the chassis. 1. Install batt eries. 2. Connect batteries. 3. Replace battery compartment door and secure door with scre ...

  • APC Smart-UPS RC 2000VA - page 8

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 9 2-post rack-mount configuration This UPS is intended for installation in a 19”, two-post or fou r-post rack. For details on 4-post rail and rack in stallation refer to instructio ns in rail kit. Remove stabilizer brackets if th ey are installed. Re ...

  • APC Smart-UPS RC 2000VA - page 9

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 10 Secure 2-post rack t o floor Inst all UPS in rack The UPS and XLBPs should be installed at or near bottom of rack. Always place UPS above XLBPs. Batteries must be r emoved from units p rior to installation in a rack . T wo screws (not supplied), mu s ...

  • APC Smart-UPS RC 2000VA - page 10

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 11 Connect internal batte ries This unit is equipped with internal battery modules. Each modul e must be connected t o battery connectors on chassis. 1. Install batteries. 2. Connect batteries. 3. Replace battery compartment door and secure door with s ...

  • APC Smart-UPS RC 2000VA - page 11

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 12 Start - u p Connect equipment and extern al battery p acks to UPS Prior to connecting the grounding cable, ensure that the UPS is NOT connect ed to utility or bat tery power . 1. Connect equipment to U PS (cables not supplied). A void using extension ...

  • APC Smart-UPS RC 2000VA - page 12

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 13 Operation Front p anel display Display p anel function buttons and indicators UPS function butt ons Button Function This button has three functions. • Press this button to turn on the UPS. • Press this button to initiate a Cold S tart . Cold Sta ...

  • APC Smart-UPS RC 2000VA - page 13

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 14 UPS indicators Indicator Description The On Line LED illuminates when UPS is draw ing utility power and performing double conversio n to supply power to connected equipment. The UPS is supplying battery pow er to connected equipment. The Bypass LED i ...

  • APC Smart-UPS RC 2000VA - page 14

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 15 Configuration UPS Settings Settings are adjusted t hrough PowerChute sof tware or optional SmartSlot ac cessory cards. Function Factory Default User Selectable Choices Description Automatic Self-T est On start-up and every 14 days (336 hr) there aft ...

  • APC Smart-UPS RC 2000VA - page 15

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 16 Output voltage Allows user to select out put voltage while on-line. 220 V models 220 V ac 200, 208, 220, 230, 240 V a c 230 V models 230 V ac 200, 208, 220, 230, 240 V a c Output frequency Automatic 50 ± 3 Hz 60 ± 3 Hz Automatic 50 ± 3 Hz, 50 ± 0 ...

  • APC Smart-UPS RC 2000VA - page 16

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 17 Emergency Power Off (EPO) The Emergency Power Off (EPO) option is a safety f eature that will immediately remove power to all connected equipment. When EPO button is pushed, al l connected equipment will immediately turn off and will not switch to b ...

  • APC Smart-UPS RC 2000VA - page 17

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 18 T roubleshooting Use the table below to solve minor installation and operatio n problems. Refer to the APC W eb site, www .apc.com for assistance with complex UPS probl ems. Problem and/or Possible Cause Solution UPS will not turn on The battery is n ...

  • APC Smart-UPS RC 2000VA - page 18

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 19 Bypass and Fault LEDs are illuminated The UPS has automatically swit ched to Bypass mode. Bypass mode operation is the result of an internal UPS fault or an overload condition while operating on utility power . In the event an internal UPS fault occ ...

  • APC Smart-UPS RC 2000VA - page 19

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 20 Maintenance and transport Battery replacement This UPS has a replacable, hot-swappable battery module . Replacement is a safe pr ocedure, isolated from electrical hazards. Leave the U PS and connected equipment on during the replacement procedure. On ...

  • APC Smart-UPS RC 2000VA - page 20

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/ 2000/3000 VA 220/230/240 Vac Tower/Ra ck-Mount 4U 21 Service If the UPS requires service do not retu rn it to the dealer . Follow these steps: 1. Review the problem s discussed in T roubleshooting in this manual to eliminate com mon problems. 2. If the problem persists, contact APC Cu stomer Support t ...

  • APC Smart-UPS RC 2000VA - page 21

    User Manual Smart-UPS RC XLI/XLICH/XLI-CC 1000/20 00/3000 VA 220/230/240 Vac Tower/Rack-Mount 4U 22 T wo-Y ear W arranty The limited warranty pr ovided by American Power Conversion (APC®) in th is statement of Limited Factory W arranty applies only to products you p urchase for your commercial or indus trial use in the ordinary course of your busi ...

メーカー APC カテゴリー Uninterruptible power supply (

APC Smart-UPS RC 2000VAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Smart-UPS RC 2000VAの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC Smart-UPS RC 2000VAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC Smart-UPS RC 2000VAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC Smart-UPS RC 2000VAの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC Smart-UPS RC 2000VAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC Smart-UPS RC 2000VAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC Smart-UPS RC 2000VAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC Smart-UPS RC 2000VAを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC Smart-UPS RC 2000VAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC Smart-UPS RC 2000VAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC Smart-UPS RC 2000VAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC Smart-UPS RC 2000VAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC Smart-UPS RC 2000VAデバイスの基本機能を使うにあたってのヒント。 APC Smart-UPS RC 2000VAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC Smart-UPS RC 2000VAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC Smart-UPS RC 2000VAのメーカー/サービスへの連絡先に関する情報。

APC Smart-UPS RC 2000VAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC Smart-UPS RC 2000VAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC Smart-UPS RC 2000VAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)