York AHP18の取扱説明書

12ページ 0.22 mb
ダウンロード

ページに移動 of 12

Summary
  • York AHP18 - page 1

    TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: AHP18 THRU 60 Due to continuous prod uc t improv e m en t, specifications are subject to change with ou t notice. Visit us on the web at www .york.com Additional rati ng information ca n be found at www .ahridirectory .org. ISO 9001 Certified Qual ...

  • York AHP18 - page 2

    255029-YTG-M-06 10 2 Johnson Controls Unitary Products DIMENSIONS 10-3/8” F CIRCUIT BREAKER P ANEL BOTTOM INLET DIMENSIONS DRAIN P AN CONNECTIONS FOR HORIZONT AL APPLICATIONS J BLOWER COMP ARTMENT REFRIGERANT CONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICA TIONS 7-1 1/32” D B A K C 1-1/2” 18-9/32” E TOP OUTLET DIMENSIONS FIL T ...

  • York AHP18 - page 3

    255029-YTG-M-0610 Johnson Controls Unitary Products 3 COIL TECHNICAL DA T A Models Application Refrig. Conn. T ypes Face Area (Sq. Ft.) Rows Deep Fin Per In. Coil Size T ube Geometry T ube Dia. Fin Ty p e TXV AHP18B3XH21 Cooling / Heat Pump Sweat 3.40 2 14 (2) 14 x 17. 5 1 x 0.866 3 /8 Enhanced None AHP18B4FH21 4E AHP24B3XH21 Cooling / Heat Pump Sw ...

  • York AHP18 - page 4

    255029-YTG-M-06 10 4 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kit s - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Non-Combustible Bases - A combustible floor base acc ...

  • York AHP18 - page 5

    255029-YTG-M-0610 Johnson Controls Unitary Products 5 All air handler units are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW s ize heater , unless otherwise noted. AIR FLOW DA T A - 60 Hz MODELS Models Blower Motor Speed 230 V olt CFM 1 @ External St atic Pressure - IWC 0.10 0.20 0.30 0 ...

  • York AHP18 - page 6

    255029-YTG-M-06 10 6 Johnson Controls Unitary Products PHYSICAL & ELECTRICAL DA T A Models AHP18B**H21 AHP24B**H21 AHP30B**H21 AHP36C**H21 Blower - Diameter x Width 9 x 6 10 x 9 10 x 9 10 x 10 Motor HP 1/3 HP 1/4 HP 1/2 HP 3/4 HP Nominal RPM 1075 1075 1075 1075 V oltage 230 Amps F ull Load (230) 1.9 1.5 2.2 3.6 Filter 1 T ype DISPOSABLE OR PERM ...

  • York AHP18 - page 7

    255029-YTG-M-0610 Johnson Controls Unitary Products 7 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Models Heater Models* Max. Static Min. Speed Ta p T otal Heat 1 kW St ag ing kW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 20 8V 240V 208V 240V 2 08V 240V AHP18B**H21 4HK*6500206 0.5 Lo 1.9 2.5 6.4 8.5 1.9 2.5 1.9 ...

  • York AHP18 - page 8

    255029-YTG-M-06 10 8 Johnson Controls Unitary Products * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models* Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amps/T ype 75 ° C Wire Size - A WG 208V 240V 208V 240V 208V 240V AHP18B**H21 4HK ...

  • York AHP18 - page 9

    255029-YTG-M-0610 Johnson Controls Unitary Products 9 ELECTRICAL DA T A (FOR MUL TI SOURCE PO WE R SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wire Size - A WG Circui t C ircuit Cir cuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 208/240 208/240 208/240 208/240 208/240 208/240 2 ...

  • York AHP18 - page 10

    255029-YTG-M-06 10 10 Johnson Controls Unitary Products 2. Heaters are 3 Phase. COOLING MODELS W ITH ELECTRIC HEA T WI RING * Optional dehumidification humidistat switch contacts open on humidity rise. Notes: 1. “Y” T erminal on Air Handle r Control Board must be connect ed for full CFM and applications requiring 60 second blower off del ay for ...

  • York AHP18 - page 11

    255029-YTG-M-0610 Johnson Controls Unitary Products 11 * Optional dehumidification humidistat switch contacts open on rise. Notes: 1. “Y” T erminal on Air Handler Contr ol Board must be connected for full CFM and applications r equiring 60 second blower off del ay for SEER enhancement. 2. Move HUM ST A T Jumper on AH Control Board to YES/NO pos ...

  • York AHP18 - page 12

    Subject to change without notice. Published in U .S.A. 255029-YTG-M-0610 Copyright © 2010 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 255029-YTG-L-0708 Johnson Controls Unitary Product s 5005 Y ork Drive Norman, OK 73069 ...

メーカー York カテゴリー Air Conditioner

York AHP18のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AHP18の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork AHP18の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York AHP18の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York AHP18の取り付け説明書、サービスマニュアル、簡易説明書、またはYork AHP18のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York AHP18の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York AHP18デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork AHP18を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork AHP18ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York AHP18の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork AHP18の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York AHP18に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York AHP18デバイスの基本機能を使うにあたってのヒント。 York AHP18のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York AHP18に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork AHP18のメーカー/サービスへの連絡先に関する情報。

York AHP18についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork AHP18の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork AHP18で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)