Belkin F6C110-RKM-2Uの取扱説明書

17ページ 0.47 mb
ダウンロード

ページに移動 of 17

Summary
  • Belkin F6C110-RKM-2U - page 1

    U ser Manual P74264 Belkin OmniGuard ™ Rackmount UPS Ensure clean and stable power to your enterprise systems F6C110-RKM-2U F6C150-RKM-2U F6C230-RKM-2U F6C320-RKM-3U ...

  • Belkin F6C110-RKM-2U - page 2

    T ABLE OF CONTENTS 3 INTRODUCTION Prod uct Overvi ew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Prod uct Hi ghligh ts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8 P ackag e Conten ts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Quick Start . . . . . . . . . . . ...

  • Belkin F6C110-RKM-2U - page 3

    W ARNING 4 W ARNING 5 NOTICE: This equipm ent has been tested an d foun d to comply with the limits f or a Class B computing d evice in accord ance with th e specificati ons in Subpart J o f P art 15 o f FCC Rules and th e Class B limits for r adio n oise emission s from digital appar atus set out in the Radi o Interfer ence o f the Canadi an Depar ...

  • Belkin F6C110-RKM-2U - page 4

    OVERVIEW 6 HIGHLIGHTS 7 The Belkin OmniGu ard Rackm ount UPS (Fi gure 1) o ffers a 2U or 3U desi gn with a capacity ran ge o f 1100V A/660 watts to 3200V A/1920 watts o f true sin e-wave output. Fig. 1: Belkin OmniGuard Rackmount UPS Design ed to save rack space f or incr easing d ensity within an en terprise environm ent, th e OmniGuar d Rackmoun ...

  • Belkin F6C110-RKM-2U - page 5

    HIGHLIGHTS 8 P ACKAGE CONTENTS 9 Please revi ew the conten ts of th e box to en sure you have all th e correct parts n eeded to corr ectly install an d use the system. • OmniGuar d Rackmount UPS •6 ft. RS232 comm unication cable •P air of stan dard black br ackets f or 19" •I n stallation m anual •W arran ty card •P ro du ct regist ...

  • Belkin F6C110-RKM-2U - page 6

    QUICK ST ART 10 PRODUCT INST ALLA TION 11 To install the OmniGuard Rackmount UPS, the follo wing steps should be f ollow ed: 1. Find a pr oper location for th e UPS devi ce . 2. M ount th e devi ce into an appr opriate r ack or alternative confi guration. 3. V erify that you’re usin g an appropri ate connector an d plug into th e wall. 4. Charg e ...

  • Belkin F6C110-RKM-2U - page 7

    13 12 Mounting the UPS within the Rack The OmniGu ard Rackmoun t UPS inclu des a m ountin g kit, which in clud es two m ountin g brack ets for a stand ard 19-in ch (48.3cm) rack an d eigh t retainin g screws f or mountin g the br ackets to th e UPS devi ce . Note that th e screws an d n ats necessary f or moun ting the UP actu al rack ar e inclu de ...

  • Belkin F6C110-RKM-2U - page 8

    PRODUCT DIAGNOSTICS 15 14 Connecting your Equipment Plug the equipm ent into th e output receptacles on th e back panel o f the unit. If your UPS is a 3U rack, th ere are a total o f eigh t outlets, with seven outlets provi ding backup plus surg e protecti on and on e outlet for sur ge-only pr otection. H owever , if your UPS is a 2U rack, ther e a ...

  • Belkin F6C110-RKM-2U - page 9

    PRODUCT DIAGNOSTICS 16 PRODUCT DIAGNOSTICS 17 T urning the Unit On/Off Press an d release the “ON/OFF/TEST” switch. After on e beep the unit will turn on and supply power to th e load. The load is immedi ately powered while the UPS run s a five-second self- test. Press an d release the switch (after on e beep)to turn the unit off. Th e UPS will ...

  • Belkin F6C110-RKM-2U - page 10

    PRODUCT DIAGNOSTICS 18 PRODUCT DIAGNOSTICS 19 Alarms ON-BA TTERY When th e UPS is operating on th e batteries , the On-Lin e LED will blink and th e audible alarm will soun d every 10 seconds. Th e alarm will stop once th e UPS r eturns to On-Lin e operati on. UPS F AUL T When th e UPS detects a hard ware f ault, the Fault LED will illumin ate and ...

  • Belkin F6C110-RKM-2U - page 11

    SOFTW ARE FEATURES & INS T ALLA TION 20 SOFTW ARE FEATURES & INS T ALLA TION 21 Communications P ort Connection Setting Up OmniGuard P ow er Management Softw are and The Interf ace Cable P ower Man agem ent so ftware an d interf ace cable kits can be used with the UPS. U se only approved in terface cables with this UPS. Conn ect the interf ...

  • Belkin F6C110-RKM-2U - page 12

    23 SOFTW ARE FEATURES & INS T ALLA TION 22 4. Double-cli ck on the U ninterruptible P ower Supply service 5. Select th e “Log On As: This Accoun t” button, input the appr opriate account inf ormation, and th en click “OK” . 6. Double-cli ck on the Contr ol Pan el’s “P ower Option s” icon. SOFTW ARE FEATURES & INS T ALLA TION 7 ...

  • Belkin F6C110-RKM-2U - page 13

    MAINTENANCE 25 F AQS 24 Battery Replacement The OmniGu ard Rackmoun t series has easy-to-r eplace hot-swappable batteri es. Please read th e following warnin g statemen ts befor e attempting to servi ce the battery(s). NO TE: If ther e is a power interrupti on while replacin g the h ot- swappable batteries , with the UPS on, the load will n ot be b ...

  • Belkin F6C110-RKM-2U - page 14

    MAINTENANCE 26 OBT AINING SERVICE 27 1. U se the TROUBLESH OO TING section to elimin ate obvious causes . 2. Verify th ere are n o circuit br eakers tripped . A tripped circuit br eaker is the m ost common pr oblem. 3. Please have the followin g informati on available BEFORE calling th e T echnical Support departm ent. b) Y our name an d add ress . ...

  • Belkin F6C110-RKM-2U - page 15

    Model F6C110-RKM-2U-230v F6C150-RKM-2U-230v F6C230-RKM-2U-230v F6C320-RKM-3U-230v VA 1100 1500 2300 3200 W atts 660 900 1380 1920 T ype Rack-Mount M odel Ag ency Approvals CE EMC & Safety W arranty 3 yr . Input (non-battery operation) V oltage Range Default* 130 to 300V AC Frequency Ran ge Auto-Sensin g 50/60Hz ± 3Hz Output (non-battery operat ...

  • Belkin F6C110-RKM-2U - page 16

    NOTICE 30 The inf ormation in this publi cation is subject to chan ge with out noti ce and is provi ded “ as is” without warr anty o f any kin d. Th e entir e risk arising out of th e use of this inf o rmation r emains with r ecipien t. In no event shall Belkin be li able f or any dir ect, consequen tial, inci den tal, special, punitive , or ot ...

  • Belkin F6C110-RKM-2U - page 17

    Belkin Corporation 501 West W alnut Street Compton • CA • 90220 • USA Te l: 310.898.1100 Fax: 310.898.1111 Belkin Components, Ltd. Express Business P ark Shipton Way • Rushd en • NN10 6GL U nited Ki ngdom Te l: +44 (0) 1933 35 2000 Fax: +44 (0) 1933 31 2000 Belkin Components B .V . Starparc Building • Boein g Avenue 333 1119 PH Schiphol ...

メーカー Belkin カテゴリー Power Supply

Belkin F6C110-RKM-2Uのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- F6C110-RKM-2Uの取扱説明書
- Belkinの製品カード
- パンフレット
- またはBelkin F6C110-RKM-2Uの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Belkin F6C110-RKM-2Uの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Belkin F6C110-RKM-2Uの取り付け説明書、サービスマニュアル、簡易説明書、またはBelkin F6C110-RKM-2Uのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Belkin F6C110-RKM-2Uの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Belkin F6C110-RKM-2Uデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBelkin F6C110-RKM-2Uを使用するのを助ける技術的文書のことです。説明書は通常、全てのBelkin F6C110-RKM-2Uユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Belkinの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Belkin F6C110-RKM-2Uの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBelkin F6C110-RKM-2Uの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Belkin F6C110-RKM-2Uに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Belkin F6C110-RKM-2Uデバイスの基本機能を使うにあたってのヒント。 Belkin F6C110-RKM-2Uのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Belkin F6C110-RKM-2Uに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBelkin F6C110-RKM-2Uのメーカー/サービスへの連絡先に関する情報。

Belkin F6C110-RKM-2Uについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBelkin F6C110-RKM-2Uの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBelkin F6C110-RKM-2Uで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)