Atlona AT-H2H-44Mの取扱説明書

30ページ 2.82 mb
ダウンロード

ページに移動 of 30

Summary
  • Atlona AT-H2H-44M - page 1

    User Manual Atlona HDMI to HDMI Matrix Switcher A T-H2H-44M and A T-H2H-88M (pictured below) atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 ...

  • Atlona AT-H2H-44M - page 2

    2 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 1. Introduction ............................................................................................ 3 2. Package Contents ............................................................................................ 3 3. Features ................................................... ...

  • Atlona AT-H2H-44M - page 3

    3 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Intr oduction Multiple control options, HD resolutions, and the best audio, the Atlona HDMI ® to HDMI matrix switcher is built for your home and professional needs. With the ability to pass 1080p, 1920x1200, all Lossy and Lossless audio formats (including Dolby ® TrueHD and DTS-HD Maste ...

  • Atlona AT-H2H-44M - page 4

    4 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The IR receiver window can sometimes pick up stray reflected IR commands causing loss of functionality. To disable the front panel, see directions below: Panel Description Front Panel IR AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXI ...

  • Atlona AT-H2H-44M - page 5

    5 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 1. Matrix IR IN: Connect included IR receiver (see picture below) 2. RS-232: Connect to this port for control from a computer or 3rd control box. 3. Firmware Update: Type B USB Port used for updating the matrix firmware only 4. Coax Out: Audio de-embedding for distribution amplifiers and ...

  • Atlona AT-H2H-44M - page 6

    6 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXIAL OUT HDMI OUT HDMI IN RS-232 ETHERNET IR IN FIRMWARE 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Connection Diagram ARC Digital audio de-embedding ARC ...

  • Atlona AT-H2H-44M - page 7

    7 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 I/O Control The AT-H2H’ s front panel has 3 functions: I/O control, EDID, and matrix settings. The following sections go over step by step setup & control. To set an input to an output To mirror all inputs and outputs -- Ex. Input 1 to output 1, input 2 to output 2, etc. To route on ...

  • Atlona AT-H2H-44M - page 8

    8 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 To load a saved I/O route To save an I/O route to memory Once inputs and outputs have been set they can be saved to memory and recalled later. Multiple individual input/output routes can be saved. The route will remain in memory until a new route has been saved to that memory number or th ...

  • Atlona AT-H2H-44M - page 9

    9 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 To copy an EDID ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to X EDIDs 2 To choose input EDID ---> ---> Copy from output # Save to Memory (1-4/8) # Copy from output # Save to Memory (1-4) # Feedback = ”Saved port # ...

  • Atlona AT-H2H-44M - page 10

    10 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Step 2: load a copied EDID onto an input ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to 4/8 EDIDs 2 To choose input EDID Input # Select an input port Input # Press Enter Current: Default Input: # Mode: 1.Default 2.Saved 3 ...

  • Atlona AT-H2H-44M - page 11

    11 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Step 3: Load an internal EDID to an input ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to 4/8 EDIDs 2 To choose input EDID Input # Select an input port Input # Press Enter Current: Default Input: # Mode: 1.Default 2.Saved ...

  • Atlona AT-H2H-44M - page 12

    12 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Matrix Settings When installing or troubleshooting it’ s important to verify settings, or be able to come back to a project and see how it was set up. The AT-H2H has matrix settings viewable through the front panel. View current I/O settings, firmware version, FPGA version, and the bau ...

  • Atlona AT-H2H-44M - page 13

    13 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 ARC enables a source connected to a display to route audio to an AVR or zone amp. The S/PDIF port is used for two audio options, ARC or matrix source audio de-embedding. When using one, the other is disabled. By default the matrix comes with ARC turned off on all ports, this enables the ...

  • Atlona AT-H2H-44M - page 14

    14 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXIAL OUT HDMI OUT HDMI IN RS-232 ETHERNET IR IN FIRMWARE 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Matrix source audio loop-out By default the matrix is enabled to de-embed source au ...

  • Atlona AT-H2H-44M - page 15

    15 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 RS-232 Connection RS-232 is connected through a 9-pin female DB connector. Only pins 2, 3, and 5 are terminated. No. Pin Function 1 ---- Not used 2 Tx Transmit 3 Rx Receive 4 ---- Not used 5 Gnd Ground 6 ---- Not used 7 ---- Not used 8 ---- Not used 9 ---- Not used 1 2 3 4 5 9 8 7 6 Set ...

  • Atlona AT-H2H-44M - page 16

    16 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 TCP/IP For convenience, the matrix comes with DHCP default on. This enables the matrix to be connected to a network or network device with no worries of the IP overriding another device. TCP/IP WebGUI Note: H2H-44M and H2H-88M screen shots will display alternately to show both GUIs Atlon ...

  • Atlona AT-H2H-44M - page 17

    17 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The home screen tab will display the general system information. If the matrix is powered off the FPGA will not display (see first image). Once the power is on it will display (see second image). Note: When the matrix is turned off many fields within the WebGUI will not display informati ...

  • Atlona AT-H2H-44M - page 18

    18 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Note: Be sure to save all changes before moving to the next page The network set up page will allow the IP information to be changed. When a change is made the screen will grey and the ability to save or cancel will display at the bottom (see below). Note: When DHCP is on, the IP cannot ...

  • Atlona AT-H2H-44M - page 19

    19 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The config page under status/setting will allow power to be turned off/on, the front IR window to be turn off/on (see page 4), and the matrix baud rate to be changed. Note: Default baud rate of the matrix has been set for the best compatiblity with other devices (i.e. projectors). Baud r ...

  • Atlona AT-H2H-44M - page 20

    20 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Adding, deleting, and updating users can also be done from the config page. User changes can only be done by the admin. Admin user name is always “root” and default password is “Atlona”. Note: Only the admin password can be changed. The username will always remain “root” Note ...

  • Atlona AT-H2H-44M - page 21

    21 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The I/O page allows input and output routes to be changed easily by drop down menu. Output All will route one selected input to all the outputs. Note: All routes can be changed while in the grey edit screen. Remember to save after all changes have been made. ...

  • Atlona AT-H2H-44M - page 22

    22 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 For compatibility and ease of use, EDID configuration has been added. Each input has a drop down selection for internal, default, and saved EDIDs (see pages 9-11 for EDID information). Note: When saving an EDID to memory through the WebGUI, the output will save to the corresponding memor ...

  • Atlona AT-H2H-44M - page 23

    23 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The HDCP page will display the output’ s ability to support HDCP content or not. Several messages will appear under different circumstances: Supported - HDCP is supported by the display Not Supported - The display is unable to support HDCP Non-HDCP Source - A source that does not suppo ...

  • Atlona AT-H2H-44M - page 24

    24 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Command Feedback Description IPCFG IP Addr : x.x.x.x Netmask : x.x.x.x Gateway : x.x.x.x IP Port: x.x.x Displays IP address configuration IPTimeout XX IPTimeout XX (Ex. IPTimout120) Determines amount of seconds of inactivity before TCP/IP disconnects IPQuit IPQuit Logs out of TCP/IP IPAd ...

  • Atlona AT-H2H-44M - page 25

    25 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 IPDelUser [X] TCP/IP user was deleted Delete a user from TCP/IP X=User (Ex. IPDelUser Atlona) IPDHCP sta IPDHCP sta Ex. IPDHCP on Displays the status of DHCP IPDHCP on IPDHCP on Turns DHCP on IPDHCP off IPDHCP off Turns DHCP off IPStatic [X] [Y] [Z] IPStatic address netmask gateway Sets ...

  • Atlona AT-H2H-44M - page 26

    26 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Updating and Resetting Updating firmware Resetting to factory settings Atlona has made field firmware updating easy. Simply download firmware from Atlona.com and upload the file to the matrix. NOTE: Only use a Windows computer to update the matrix. Use of an Apple computer to update will ...

  • Atlona AT-H2H-44M - page 27

    27 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Bandwidth 6.75Gbps Ports Video input Video output Audio output IR input Control: RS-232 Control: TCP/IP Firmware update AT-H2H-44M 4 x HDMI 4 x HDMI 4 x S/PDIF 1 x 3.5 mm 1 x 9pin (RS-232) 1 x RJ45 1 x USB B AT-H2H-88M 8 x HDMI 8 x HDMI 8 x S/PDIF 1 x 3.5 mm 1 x 9pin (RS-232) 1 x RJ45 1 ...

  • Atlona AT-H2H-44M - page 28

    28 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Safety Information Safeguards Precautions FCC regulations state that any unauthorized changes or modifications to this equipment, not expressly approved by the manufacturer, could void the user’ s authority to operate this equipment. Operate this product using only the included externa ...

  • Atlona AT-H2H-44M - page 29

    29 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Atlona, Inc. (“Atlona”) Limited Pr oduct Warranty Policy Coverage Atlona warrants its products will substantially perform to their published specifications and will be free from defects in materials and workmanship under normal use, conditions and service. Under its Limited Product W ...

  • Atlona AT-H2H-44M - page 30

    30 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Atlona, Inc Pr oduct Registration Thank you for purchasing this Atlona product. - We hope you enjoy it and will take an extra few moments to register your new purchase. Registration creates an ownership record if your product is lost or stolen and helps ensure you’ll receive notificati ...

メーカー Atlona カテゴリー Plumbing Product

Atlona AT-H2H-44Mのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AT-H2H-44Mの取扱説明書
- Atlonaの製品カード
- パンフレット
- またはAtlona AT-H2H-44Mの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Atlona AT-H2H-44Mの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Atlona AT-H2H-44Mの取り付け説明書、サービスマニュアル、簡易説明書、またはAtlona AT-H2H-44Mのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Atlona AT-H2H-44Mの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Atlona AT-H2H-44Mデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAtlona AT-H2H-44Mを使用するのを助ける技術的文書のことです。説明書は通常、全てのAtlona AT-H2H-44Mユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Atlonaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Atlona AT-H2H-44Mの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAtlona AT-H2H-44Mの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Atlona AT-H2H-44Mに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Atlona AT-H2H-44Mデバイスの基本機能を使うにあたってのヒント。 Atlona AT-H2H-44Mのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Atlona AT-H2H-44Mに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAtlona AT-H2H-44Mのメーカー/サービスへの連絡先に関する情報。

Atlona AT-H2H-44Mについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAtlona AT-H2H-44Mの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAtlona AT-H2H-44Mで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)