Foster FHG 2Lの取扱説明書

20ページ 0.57 mb
ダウンロード

ページに移動 of 20

Summary
  • Foster FHG 2L - page 1

    Display Case FHG 2L & FHG 3L ...

  • Foster FHG 2L - page 2

    1 Foster Refrigerator Environmental Manag ement Policy Product Support and Installation Contra ctors Foster Refrigerator recog nises that its activities, products and services can have an adverse impa ct upon the environment. The organisation is committed to implementing systems and controls to manage, reduce and eliminate its adverse environmental ...

  • Foster FHG 2L - page 3

    2 Introduction The display case are manufactured in two formats FHG 2L, 2 doors, and the F HG 3L, three doors. There are also Multiplex options that are a combi nation of two FHG 2L cases to make a FHG 4L or a combinatio n of the FHG 2L and FHG 3L to make a FHG 5L. Technical Specification. Model 2 Door 3 Door 4 Door 5 Door External Dimensions (m) H ...

  • Foster FHG 2L - page 4

    3 Temperature controller It is strongly advised that b efore adjusting any Serv ice Parameters a thorough understanding o f the following instructions should be obtained. Carel PB00F0HB10 Controller Display and Symbols. NOTE: When the buttons are presse d a brief audible signal is emitted; this signal can not be disabled. 1. HACCP: Pressing this bu ...

  • Foster FHG 2L - page 5

    4 9. Compressor: Illuminated when the co mpressor is running. Flashes when the activation of the compre ssor is delayed by safety times. 10. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to extern al disabling or proced ures in pr ogress. 11. DEFROST: Illuminated when defrost is activated. Flashes whe ...

  • Foster FHG 2L - page 6

    5 3. Confirm by pressing . 4. The display shows the code of the first modifiable type “C” paramete r. Modifying the parameters. After having accessed the parameters, either type “C” or typ e “F”, proceed as follows. 1. Press or until the parameter to be modified is reach ed, when scrolling through an icon appears on the display indicati ...

  • Foster FHG 2L - page 7

    6 Classification of Parameters The parameters, as well as being divided into type, are al so grouped into logical categories identified by the initial letters or symbols of such parameters. The following t able lists the catego rise and the corresponding letters. Parameter Category Text Icon / Temperature probe parameters ‘Pro’ r Temperature co ...

  • Foster FHG 2L - page 8

    7 35 c9 Enable autostart with PD operation flag 0 0 0 36 c10 Select Pd by time or pressure flag 0 0 0 37 c11 Delayed compressor delay sec 4 4 4 38 d0 Type of defrost flag 0 1 1 39 dI Interval between defrosts hours 8 6 6 40 dt1 End defrost temperature, evaporator. °C/°F 4.0 20.0 20.0 41 dt2 End defrost temperat ure, aux. evaporator °C/°F 4.0 4. ...

  • Foster FHG 2L - page 9

    8 Parameter Definitions /2 Measurement stability. Defines the coefficient used to stabili se the temperature reading. /3 Probe display rate Sets the rate at which the temperature display is updated. /4 Probe average (Virtual probe) Used to choose whether to control the tempe rat ure based solely on the roo m probe reading, or alternatively whether ...

  • Foster FHG 2L - page 10

    9 r3 Operating mode The controller can work as a thermostat an d defrost cont roller (r3 = 0), or as a simple thermo stat in direct operation (r3 = 1), or as a simple thermostat in Reverse- cycle op eration (r3 = 2). Default setting: r3 = 0. r4 Automatic variation of the set point in night time oper ation. Default: 3.0. Not used by Foster r5 Enable ...

  • Foster FHG 2L - page 11

    10 c11 Delayed compressor delay Not used by Foster Default: c11 = 4 d0 Type of Defrost Sets the type of defrost required. Default: d0 = 0. Foster setting d0 = 1. Hot gas defrost termi nated by evaporator probe or in the event of probe failure by time (see dP1). dI Interval between defrosts. The defrosts are performed peri odically at an in terval e ...

  • Foster FHG 2L - page 12

    11 d/1 Display defrost probe. Displays the value measured by the defrost probe. Once d/1 has been selected pre ss the button to display the temperature measured by the defrost probe. d/2 Display defrost prob e 2 reading. Not used by Foster. dC Base time for defrost. Not used by Foster Default: dC = 0. d10 Compressor running time. Not used by Foster ...

  • Foster FHG 2L - page 13

    12 Default: A6 = 0. A7 External alarm detection delay . Not used by foster Default: A7 = 0. A8 Enables alarm ‘Ed1’ and ‘Ed2’. Not used by Foster. Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled. Ado Door switch light management mode. Not used by Foster. Default: Ado = 0. Ac High condenser temperatu re alarm. Not used by Foster. De ...

  • Foster FHG 2L - page 14

    13 Default: H3 = 0. H4 Disable buzzer. H4 = 0 buzzer enabled. H4 = 1 buzzer disabled. Default: H4 = 0. H5 Function of relay 5 . Not used by Foster. Default: H5 = 3. H6 Lock out Butto ns. Not used by Foster. Default: H6 = 0. H7 Select Keypad. Used to select the type of keypad on the controller. Default: H7 = 0. Use the standard controller. HPr Print ...

  • Foster FHG 2L - page 15

    14 MCB Siemens 5SY6316 –8 TP 16 Amp 3 Pole 16240209 X X Wiring diagrams The drawings numbers for the display cases are a s follows: FHG2L - 2 door unit single pha se 00-233867-02 FHG2L - 2 door unit three phase 00-233868-02 FHG3L - 3 door unit three phase 00-233869-02 ...

  • Foster FHG 2L - page 16

    15 ...

  • Foster FHG 2L - page 17

    FHG2L - 2 door unit single pha se 00-233867-02 ...

  • Foster FHG 2L - page 18

    FHG2L - 2 door unit three phase 00-233868-02 ...

  • Foster FHG 2L - page 19

    1 FHG3L - 3 door unit three phase 00-233869-02 ...

  • Foster FHG 2L - page 20

    Foster European Operations France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com Germany Foster Refrigerator Gmbh, Tel: (49) 2333 839375. Fax (49) 2333 8393 77. Email: info@foster-gmbh.de Foster Refriger ator Oldmedow Road Kings Lynn Norfolk PE30 4JU Tel: 01553 691122 Fax: 01553 ...

メーカー Foster カテゴリー Refrigerator

Foster FHG 2Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FHG 2Lの取扱説明書
- Fosterの製品カード
- パンフレット
- またはFoster FHG 2Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Foster FHG 2Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Foster FHG 2Lの取り付け説明書、サービスマニュアル、簡易説明書、またはFoster FHG 2Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Foster FHG 2Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Foster FHG 2Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFoster FHG 2Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのFoster FHG 2Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Fosterの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Foster FHG 2Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFoster FHG 2Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Foster FHG 2Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Foster FHG 2Lデバイスの基本機能を使うにあたってのヒント。 Foster FHG 2Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Foster FHG 2Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFoster FHG 2Lのメーカー/サービスへの連絡先に関する情報。

Foster FHG 2Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFoster FHG 2Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFoster FHG 2Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)