    Imp2DigAdvServ REV 3/20/08 SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1132-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A WITH PUSH BUTTON CONTROLS Lincoln Foodservice ...

  • Lincoln 1116-080-A - page 2

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 2 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, GAS (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A LP GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. 1 PHASE POWER ...

  • Lincoln 1116-080-A - page 3

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 3 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, ELECTRIC (OVENS WITH PUSH BUTTON CONTROLS) 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-0 ...

  • Lincoln 1116-080-A - page 4

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 4 SCHEMATIC DIAGRAM MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 ...

  • Lincoln 1116-080-A - page 5

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 5 SCHEMATIC DIAGRAM MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 SCHEMATIC DIAGRAM ...

  • Lincoln 1116-080-A - page 6

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 6 MODEL 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1 ...

  • Lincoln 1116-080-A - page 7

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 7 SCHEMATIC DIAGRAM MODEL 1161-080-A ...

  • Lincoln 1116-080-A - page 8

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 8 SCHEMATIC DIAGRAM MODEL 1162-080-A ...

  • Lincoln 1116-080-A - page 9

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 9 SCHEMATIC DIAGRAM MODEL 1130-08H-A, 1131-08H-A ...

  • Lincoln 1116-080-A - page 10

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 10 SCHEMATIC DIAGRAM MODEL 1132-08H-A, 1133-08H-A ...

  • Lincoln 1116-080-A - page 11

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 11 TROUBLESHOOTING GUIDE GAS OVENS MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. MODEL 1117-080-A LP GAS 120VAC 60 HZ. MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. SYMPTOM POSSIBLE CAUSE EVALUATION Oven fan will not run Incoming power supply Check cir ...

  • Lincoln 1116-080-A - page 12

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 12 the main fan motor) to neutral. If no voltage is present, trace wiring back to the main power switch. If voltage is present, check for 120VAC at wire #22 (output of centrifugal switch) to neutral. If no voltage is present at #22, and the motor is runni ng, repla ce the main fa ...

  • Lincoln 1116-080-A - page 13

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 13 occur. If flame is not detected, the ignition control will shut off and lock out. To reset the ignition control, turn off the power switch for 45 seconds, then turn the switch on to re-try ignition. The igniti on control requires a minimum of 0.8 DC mi croamp s to prove flame. ...

  • Lincoln 1116-080-A - page 14

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 14 Oven control If the thermoc ouple checks good, but the oven control display indicates that there is a therm ocouple failure, replace the oven control. If the oven control indicates a temperature reading but the oven wo n’t heat, proceed. Thermocouple WITH POWER ON AND T HERM ...

  • Lincoln 1116-080-A - page 15

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 15 needed. WARNING: Capacitor ha s a stored charge, discharge before testing. Switch, conveyor reversing Check continuity between swit ch terminals. Replace switch as needed. Oven control If there is 120VAC supplied to the motor, and the motor, capacitor, and reversing switch che ...

  • Lincoln 1116-080-A - page 16

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 16 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-08H-A 240 VAC 60 HZ. 1 PHASE 1132-080-A 120/208VAC 60 HZ. 3 PHASE 1132-080-A1 120/208VAC ...

  • Lincoln 1116-080-A - page 17

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 17 Replace relay as needed. Main fan runs after 20 minute cool down Oven start relay Contacts should open whe n main power switch is turned off. Replace relay as needed. 20 Minute time delay 120VAC at terminal # 2 sh ould discontinue approx. 20 minutes after main power is switche ...

  • Lincoln 1116-080-A - page 18

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 18 If there is a read-out on the control, set the co ntrol to maximum temperature (see installation operations manual for temperature adju stment). With the control set at maximum temperature, check for supply voltage at mercury contactor. If there is voltage at the mercury conta ...

  • Lincoln 1116-080-A - page 19

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 19 thermal protection and w ill cease to operate if overheating occurs. As the motor overheats and then cools, this will cause the oven to cycle on a nd off intermittently. Improper ventilation or lack of preventive maintenance may cause this. Also, most of the problems listed un ...

  • Lincoln 1116-080-A - page 20

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 20 Conveyor motor If there is voltage supplied to the hall effect sensor, check for a frequency output fro m the hall effect sensor. Measure frequen cy across the yellow and white wires at the motor connecto r. Frequency reading sho uld be approx. 25 – 100 Hz. If these readings ...

  • Lincoln 1116-080-A - page 21

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 21 CAPACITOR – REPLACEMENT A. Shut off power at main breaker. B. Remove rear control box cover. C. Discharge capacitor. D. Remove capacitor. E. Reassemble in reverse order and check system operation. ON/OFF SWITCH – REPLACEMENT A. Shut off power at main breaker. B. Remove con ...

  • Lincoln 1116-080-A - page 22

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 22 F. Reassemble in reverse ord er and check system oper ation. Be sure capill ary tube is securely in the mount. NOTE: Push reset butt on on new thermostat. TRANSFORMER, BURNER – REPLACEMENT A. Shut off power at main breaker. B. Remove conveyor and front control box cover. C. ...

  • Lincoln 1116-080-A - page 23

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 23 BURNER CONTROL – REPLACEMENT A. Shut off power at main breaker. B. Remove conveyor and front control box cover. C. Remove wires from control and mark for reassembly. D. Remove mounting screws from control and rem ove burner control. E. Reassemble in reverse order and check s ...

  • Lincoln 1116-080-A - page 24

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 24 BYPASS ORIFICE – REPLACEMENT A. Shut off power at main breaker. B. Shut off gas supply to the oven and di sconnect the flexible gas line to oven. C. Remove rear control box cover. D. Disconnect bypass tube from gas valve. E. Remove bypass orifice from gas valve. F. Reassembl ...

  • Lincoln 1116-080-A - page 25

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 25 G. Turn adjusting screw on ai r pressure switch fully counter clockwi se. H. Turn oven “on”. I. Turn adjusting screw on air pressure switch clockwise until heat shuts off. J. Turn adjusting scre w on ai r pressu re switch counter clockwise ¼ tu rn. K. Reassemble control p ...

  • Lincoln 1116-080-A - page 26

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 26 GENERAL VIEW IMPINGER II ADVANTAGE MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1132-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUM ...

  • Lincoln 1116-080-A - page 27

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 27 GENERAL VIEW ...

  • Lincoln 1116-080-A - page 28

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 28 CONTROL BOX, FRONT MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369805 Switch, on/off B 370408 Facia, pushbutton C 370417 Control board 370409 Display (digital only) D 369531 Transformer, 24VAC E 369507 Thermostat, cooling fan F 36912 ...

  • Lincoln 1116-080-A - page 29

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 29 CONTROL BOX, FRONT VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 ...

  • Lincoln 1116-080-A - page 30

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 30 CONTROL BOX, FRONT MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUMBER DESCRIPTION A 369680 Front cover assy. B 369508 Timer, 20 minu ...

  • Lincoln 1116-080-A - page 31

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 31 CONTROL BOX, FRONT VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A ...

  • Lincoln 1116-080-A - page 32

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 32 CONTROL BOX, REAR MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369192 Capacitor B 370378 Conveyor motor assy. (S/N 2052462 & Below) 370675 Conveyor motor as sy. (S/N 2052463 & Above) C 369901 Burner manifold D 369568 Burner ve ...

  • Lincoln 1116-080-A - page 33

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 33 CONTROL BOX, REAR VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 ...

  • Lincoln 1116-080-A - page 34

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 34 CONTROL BOX REAR MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUMBER DESCRIPTION A 369192 Capacitor B 369200 Relay, main fan C 369124 ...

  • Lincoln 1116-080-A - page 35

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 35 CONTROL BOX, REAR VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A ...

  • Lincoln 1116-080-A - page 36

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 36 OVEN BACK ASSEMBLY LETTER PART NUMBER DESCRIPTION A 369182 Fan B 369899 Fan shroud C 369655 Stand off D Heating element 369183 208 Volt 369184 240 Volt 370648 208 Volt – Models 1130-08H-A & 1132-08H-A (S/N 10062053640 & below) 370645 240 Volt – Models 1131-08H-A &a ...

  • Lincoln 1116-080-A - page 37

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 37 OVEN BACK ASSEMBLY VIEW ...

  • Lincoln 1116-080-A - page 38

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 38 CONVEYOR / DOOR LETTER PART NUMBER DESCRIPTION A 369190 Coupler (S/N 2052462 & below) 370671 Coupler (S/N 2052463 & above) B 369512 Coupling center (S/N 2052462 & below) C 369269 Ball plunger (S/N 2052462 & below) D 370116 Set screw (S/N 2052462 & below) E ...

  • Lincoln 1116-080-A - page 39

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 39 CONVEYOR / DOOR VIEW ...

  • Lincoln 1116-080-A - page 40

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 40 ...

メーカー Lincoln カテゴリー Convection Oven

Lincoln 1116-080-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1116-080-Aの取扱説明書
- Lincolnの製品カード
- パンフレット
- またはLincoln 1116-080-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln 1116-080-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln 1116-080-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln 1116-080-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln 1116-080-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln 1116-080-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln 1116-080-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln 1116-080-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincolnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln 1116-080-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln 1116-080-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln 1116-080-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln 1116-080-Aデバイスの基本機能を使うにあたってのヒント。 Lincoln 1116-080-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln 1116-080-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln 1116-080-Aのメーカー/サービスへの連絡先に関する情報。

Lincoln 1116-080-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln 1116-080-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln 1116-080-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)