Pelco C1498M-Bの取扱説明書

20ページ 0.16 mb
ダウンロード

ページに移動 of 20

Summary
  • Pelco C1498M-B - page 1

    Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435 ® DD5T A Series Dome Drive Installation/ Operation Man ...

  • Pelco C1498M-B - page 2

    2 Pelco Manual C1498M-B (7/99) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS ................................................................ 3 DESCRIPTION ................................................................................................................... 3 MODELS ......................................................... ...

  • Pelco C1498M-B - page 3

    Pelco Manual C1498M-B (7/99) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Observe the f ollowing warnings before installing and using this product. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, ...

  • Pelco C1498M-B - page 4

    4 Pelco Manual C1498M-B (7/99) 2. Set the s witches on the bottom of the dome drive. Ref er to T able A f or the settings for SW1, and T able B and T able C for SW2. 3. Install the dome drive in the bac k box. Line up the green tab and red tab on the dome drive with the green label and red label on the bac k bo x. Raise the dome drive into the back ...

  • Pelco C1498M-B - page 5

    Pelco Manual C1498M-B (7/99) 5 Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ...

  • Pelco C1498M-B - page 6

    6 Pelco Manual C1498M-B (7/99) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF OFF 64 OFF OFF OFF OFF OFF OFF ...

  • Pelco C1498M-B - page 7

    Pelco Manual C1498M-B (7/99) 7 1 1 3 ON OFF OFF OFF ON ON ON OFF 1 1 4 OFF ON OFF OFF ON ON ON OFF 1 1 5 ON ON OFF OFF ON ON ON OFF 1 1 6 OFF OFF ON OFF ON ON ON OFF 1 1 7 ON OFF ON OFF ON ON ON OFF 1 1 8 OFF ON ON OFF ON ON ON OFF 1 1 9 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON ON OFF 121 ON OFF OFF ON ON ON ON OFF 122 OFF ON OFF ON ON ON ...

  • Pelco C1498M-B - page 8

    8 Pelco Manual C1498M-B (7/99) 169 ON OFF OFF ON OFF ON OFF ON 170 OFF ON OFF ON OFF ON OFF ON 171 ON ON OFF ON OFF ON OFF ON 172 OFF OFF ON ON OFF ON OFF ON 173 ON OFF ON ON OFF ON OFF ON 174 OFF ON ON ON OFF ON OFF ON 175 ON ON ON ON OFF ON OFF ON 176 OFF OFF OFF OFF ON ON OFF ON 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ...

  • Pelco C1498M-B - page 9

    Pelco Manual C1498M-B (7/99) 9 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON ON ON 235 ON ...

  • Pelco C1498M-B - page 10

    10 Pelco Manual C1498M-B (7/99) P AN AND TIL T FUNCTIONS Use your controller’ s joystic k to control pan and tilt operation. • Fixed-Speed Controllers – P an and tilt operation is at a fix ed speed; the controller determines the speed. • V ariable-Speed Controllers – Depending on the joystic k’s position, standard pan operation ranges f ...

  • Pelco C1498M-B - page 11

    Pelco Manual C1498M-B (7/99) 11 Software controls scan limit stops . When the dome reaches one , it immediately re verses direction. Refer to the Limit Stops section to program the scan limit stops . Program preset 96 (29) to stop a scan. Any pan and tilt or lens command also stops a scan. P ARK If the dome does not receive an y commands f or a spe ...

  • Pelco C1498M-B - page 12

    12 Pelco Manual C1498M-B (7/99) CM9750 1. T ur n the KEY SWITCH to the ON position. 2. Press the PROG k ey . PROGRAM appears on the LCD screen. 3. Press the PRES ke y . The PRESET prompt appears. 4. Enter 95 and press the ENTER ke y . The main menu appears . 5. T ur n the KEY SWITCH to the OFF position. CM9760 1. In the default men u, select DEF . ...

  • Pelco C1498M-B - page 13

    Pelco Manual C1498M-B (7/99) 13 GAIN/AGC AGC Mode The two AGC (A utomatic Gain Control) modes are auto and off. • In auto mode, the dome automatically adjusts the gain–the amount of amplification the camera places on its video inf ormation to obtain a full 1-volt peak-to-peak video signal out. If the iris is manually opened to its wide-open pos ...

  • Pelco C1498M-B - page 14

    14 Pelco Manual C1498M-B (7/99) 6. Mov e the jo ystick up or do wn to position the cursor beside one of the choices. Press the Iris Open button. MODE – The cursor mov es to one of two choices: A uto or Off. In the Auto mode , the iris is automatically adjusted to produce a constant video output as determined by the Level setting below . In the Of ...

  • Pelco C1498M-B - page 15

    Pelco Manual C1498M-B (7/99) 15 T o change the mode: 1. On the main menu, mov e the joystick up or do wn to position the cursor (>) beside Camera. 2. Press the Iris Open button to enter the Camera submenu. 3. Mov e the jo ystick up or do wn to position the cursor beside Ne xt. 4. Press the Iris Open button to go to the ne xt camera submenu. 5. M ...

  • Pelco C1498M-B - page 16

    16 Pelco Manual C1498M-B (7/99) T o change the line synchronization settings: 1. On the main menu, mov e the joystick up or do wn to position the cursor (>) beside Line Sync. 2. Press the Iris Open button. Another menu appears with the Line Sync and Line Sync Phase selections. 3. Mov e the jo ystick up or do wn to position the cursor beside one ...

  • Pelco C1498M-B - page 17

    Pelco Manual C1498M-B (7/99) 17 LIMIT STOPS The two types of limit stop are manual and scan. When manual limit stops are set, a manual (joystic k) pan operation stops when a limit is reached. When scan limit stops are set, the dome rev erses direction during random, frame, and auto scanning when a limit stop is reached. Software controls limit stop ...

  • Pelco C1498M-B - page 18

    18 Pelco Manual C1498M-B (7/99) 3. Mov e the jo ystick up or do wn to position the cursor beside Scan Speed deg/s. 4. Press the Iris Open button. The cursor mov es to the right beside the current number of degrees. 5. Move the joystick up or down to toggle through the number of degrees (1-40) until you reach the number you w ant. (If set on a lo w ...

  • Pelco C1498M-B - page 19

    Pelco Manual C1498M-B (7/99) 19 8. If the red power LED is lit, turn off power . a. Open the door to the interconnect circuit board and check that all connectors are fully seated. b. Make sure the wiring is correct between the unit and controller . c. Close the door . Check the switch settings on the dome driv e (ref er to T ables A, B, and C) and ...

  • Pelco C1498M-B - page 20

    20 Pelco Manual C1498M-B (7/99) REVISION HISTOR Y Manual # Date Comments C1498M 2/99 Original v ersion. 3/99 Remo ved reference to line synchronization. Added material on auto iris. Added FCC notice. C1498M-A 7/99 Revised the preset tilt speed from 100 to 200 deg rees/second. Added model number and specifications for a P AL camera. Revised T rouble ...

メーカー Pelco カテゴリー Welder

Pelco C1498M-Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C1498M-Bの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C1498M-Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C1498M-Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C1498M-Bの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C1498M-Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C1498M-Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C1498M-Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C1498M-Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C1498M-Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C1498M-Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C1498M-Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C1498M-Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C1498M-Bデバイスの基本機能を使うにあたってのヒント。 Pelco C1498M-Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C1498M-Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C1498M-Bのメーカー/サービスへの連絡先に関する情報。

Pelco C1498M-Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C1498M-Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C1498M-Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)