  • Fujitsu PRIMERGY RX300 S5 - page 1

    PRIMERGY RX300 S5 System configurator and order-information g uide Contents Instructions Configuration diagr am Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible driv es VI Hard disk drives VII PCI Controller VIII Communication/Network IX System M anagement Products ( RemoteView ) X Mi scellaneous XI Count ...

  • Fujitsu PRIMERGY RX300 S5 - page 2

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/System-Architect. Only these tools will ensure a fast and proper configur ation of your PRIMERGY server or yo ur complete PRIMER ...

  • Fujitsu PRIMERGY RX300 S5 - page 3

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Configuration diagram PRIM ERGY RX300 S5 Sy stem unit ( I ) with 3.5" Hard disk drives Moth erboard front side Memory CPU1 ( Channel 0 + 1 +2 ) 3 USB Bank 1 (3 Modules) Xeo n DP Air channel VGA Bank 2 (3 Modules) Frontp. Bank 3 (3 Modules) Bay for LocalView ...

  • Fujitsu PRIMERGY RX300 S5 - page 4

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Configuration diagram PRIM ERGY RX300 S5 Sy stem unit ( I ) with 8 or 12 2.5" Hard disk drives Moth erboard front side Memory CPU1 middle ( Channel 0 + 1 +2 ) 3 USB Bank 1 (3 Modules) Xeo n DP Air channel VGA Bank 2 (3 Modules) Frontp. Bank 3 (3 Modules) Ba ...

  • Fujitsu PRIMERGY RX300 S5 - page 5

    System c onfigurator and or der-information guide Start PRIMER GY RX300 S5 PRIMERGY RX 300 S5 Status 2010-04-3 0 SW - Configurator 32 bit wit h OEM-Software wit hout OEM-Software for PRIMERG Y Server for PRIMERG Y Server OEM-SW is bou nd to HW and VMw are-Software is not a llow ed to be orde red - Virtual Infrastructu re 3 Usage of OEM SW from MS i ...

  • Fujitsu PRIMERGY RX300 S5 - page 6

    System c onfigurator and or der-information guide Start PRIMER GY RX300 S5 PRIMERGY RX 300 S5 Status 2010-04-3 0 SW Configu rator EM64T wit h OEM-Software w ithout OEM-Software for PRIMERG Y Server for PRIMERG Y Server For all SW produ cts please refer to the correspo ndi ng software con figurator accessibl e via th e Extrane t un der "Con fig ...

  • Fujitsu PRIMERGY RX300 S5 - page 7

    Sy stem configurato r and orde r-information guide Start PRIMERGY RX300 S5 PRIMERGY RX300 S5 Statu s 2010-04 -30 Section I Basic unit System unit consisting of: * 2U Housing including one pow er supply module - hot plug Power suppl y uni t with 1 PSU module and power cord rack 4m le nght (can be upgraded with on e additiona l PSU module ) * Fan uni ...

  • Fujitsu PRIMERGY RX300 S5 - page 8

    Sy stem configurato r and orde r-information guide A PRIMERGY RX300 S5 Statu s 2010-04 -30 Cables included in basic unit Connections Cable PRIMERGY RX300 S5  SAS 1. SATA DVD    SATA 2. SAS cab les to HDDs   1x cable for SAS signaling   3. Pow er cable Rack version for 19'' racks with Rack version for 19'' ...

  • Fujitsu PRIMERGY RX300 S5 - page 9

    Sy stem configurato r and orde r-information guide B PRIMERGY RX300 S5 Statu s 2010-04 -30 PRIMERGY 19" Rack S26361-F2735 -E101 S26361-F2735 -E110 S26361-F2735 -E111 RMK-F1_1-2U Server RMK-P_1-2U Server No Rackmou nt-Kit option telescopic rai l, full extractio n, telescopic rai l, partial ex traction Only for loose deli veries 1-hand-mounting ...

  • Fujitsu PRIMERGY RX300 S5 - page 10

    Sy stem configurato r and orde r-information guide C PRIMERGY RX300 S5 Statu s 2010-04 -30 Section II Processor There are 2 processor sockets availab le. The first socket is alway s equipped wi th the first CPU which can be selected via configurator It is also possible to upgrad e a dual-processor sy stem later on with a second CPU Two processors w ...

  • Fujitsu PRIMERGY RX300 S5 - page 11

    Sy stem configurato r and orde r-information guide D PRIMERGY RX300 S5 Statu s 2010-04 -30 Section III Memory - There are 9 memory slots for max. 72GB DDR3 RAM per CPU available with 8GB DIMMs => max. 144GB for two CPU`s ( 72GB per CPU ) ( For explanation of followi ng terms refer to sect ion "Memory Configurations" - The memor y area ...

  • Fujitsu PRIMERGY RX300 S5 - page 12

    Sy stem configurato r and orde r-information guide PRIMERGY RX300 S5 Statu s 2010-04 -30 E1 E2 S26361-F3284 -E1 S26361-F3284 -E2 Spare Channel Mode Installation P erformance Mode Inst allation With this order code a BIOS setup With this order code BIOS setup for spare mode i s fact ory pr einstall ed is default for hig hest performance The three id ...

  • Fujitsu PRIMERGY RX300 S5 - page 13

    Sy stem configurato r and orde r-information guide PRIMERGY RX300 S5 Statu s 2010-04 -30 F1 F2 S26361-F3284 -E3 Mirrored Channel Mode Installation With this order code a BIOS setup for Mirrored Channel Mode i s factory prei nstalled The two identi cal memor y modu les of followi ng order codes are al ways equipp ed in one mem ory ban k to use the M ...

  • Fujitsu PRIMERGY RX300 S5 - page 14

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Memory Configuration PRIMERGY RX300 S5 Each CPU offers 9 Slots f or DDR3 Me mory Modules organised in 3 Banks and 3 Channels. If you need more than 9 Slots you have to configure the 2nd CPU. Depending on the amount of m emory configured you can decide betwe en 4 ...

  • Fujitsu PRIMERGY RX300 S5 - page 15

    1. Independen t Channel Mode required required if 2nd CPU is configured Bank I Data Dat a Data Data Data Data optional, same type in Bank per CPU (black sockets) Bank II Data Dat a Data Data Data Data optional, any type (blue sockets) Bank III Data Dat a Data Data Data Data ----- --- not used (green sockets) Independent Cha nnel Mode allow s all ch ...

  • Fujitsu PRIMERGY RX300 S5 - page 16

    Sy stem configurato r and orde r-information guide G PRIMERGY RX300 S5 Statu s 2010-04 -30 Section V Accessible drives Setup RX3 00 S5 by ServerStart is supported wi th followi ng configuration s: no DVD, no CD: remote in stallation on ly ( PX E service & DHCP server required) built in CD/DVD or USB CD/DVD disk drive: UNC Network share reachabl ...

  • Fujitsu PRIMERGY RX300 S5 - page 17

    Sy stem configurato r and orde r-information guide H PRIMERGY RX300 S5 Statu s 2010-04 -30 Section VI Hard disks drives Modular Raid controller is connected to internal HDDs For basic units V1xx up to 6 SAS 3.5" hard disks can be configur ed also in mi xed configura tion. If the option "Tape drive" is configured onl y 4 bay s for har ...

  • Fujitsu PRIMERGY RX300 S5 - page 18

    Sy stem configurato r and orde r-information guide H PRIMERGY RX300 S5 Statu s 2010-04 -30 Section VI SAS 6G HD's and Controller for basic units V2xx up to 8 SAS 2.5" For basic units V2xx up to 8 SAS 2.5" hard disks pl us the option "Tape drive" can be configured. Mixed configurations with SS D and SATA 2.5" HD`s are N ...

  • Fujitsu PRIMERGY RX300 S5 - page 19

    System c onfigurator and or der-information guide I PRIMERGY RX 300 S5 Status 2010-04-3 0 Section VII Modular Raid 0/1 an d Raid5 Controller S2636 1-F3257-E8 Modular Raid 0/1 co ntroller w ith IME support for SAS/SA TA-HDs 8 port SAS RAID C ontroll er IME (Integrated Mirrorin g Enh an ced) offers the RAID le vels 0, 1, 1E LSI IME is a RA ID 0, 1 im ...

  • Fujitsu PRIMERGY RX300 S5 - page 20

    System c onfigurator and or der-information guide J PRIMERGY RX 300 S5 Status 2010-04-3 0 SAS-/SC SI-/ Fibre-Channel Controller Low Profile * 2 PCIe-2 slots wi red x8 an d 5 PCIe-2 slo ts wired x4 : A PCIe-2 x4 card can al so be plu gged in a PCIe-2 x8 slot Slot 7 an d 6 are w ired x 8 a nd n otched A PCIe-2 x8 card can also be plugged i n a PCIe - ...

  • Fujitsu PRIMERGY RX300 S5 - page 21

    System c onfigurator and or der-information guide K PRIMERGY RX 300 S5 Status 2010-04-3 0 SAS RA ID controller for JBOD su bsystems S2636 1-F3890-E2 01 S2636 1-F3890-E2 30 8 port SAS RAID C ontroll er 8 port SAS RAID C ontroll er LSI LSI MegaRA ID SAS8880 E M egaRAID SAS88 80E 512M B Cache with ECC 512M B Cache with ECC iBBU max. 2x per system poss ...

  • Fujitsu PRIMERGY RX300 S5 - page 22

    System c onfigurator and or der-information guide L PRIMERGY RX 300 S5 Status 2010-04-3 0 Section VIII Communica tion / Netw ork Dual Port GBit on-board L AN Controller Teaming: Failover, Load Balancing Gigabi t Ethern et Control ler on -board The In tel LAN Co ntroll ers 1000TX an d 1000S X Dua l Port GBit LAN con trolle r can be u sed wi th th e ...

  • Fujitsu PRIMERGY RX300 S5 - page 23

    System c onfigurator and or der-information guide M PRIMERGY RX 300 S5 Status 2010-04-3 0 Section IX System Manag ement Products (RemoteView) S2636 1-F1790-E2 41 iRMC S2 advan ced pack in tegrated remote managemen t controll er activation key for graphi cal consol e redirectio n and remote media redirecti on max. 1x per system S2636 1-F1790-E2 21 R ...

  • Fujitsu PRIMERGY RX300 S5 - page 24

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Change Report Date Order number Changes 2010-04 -06 S26361-F36 01-E160/500 new BC-SATA HD drives - now available 2009-10 -01 S26361-F32 99-E32/64 new SSD HD drives - as soon as availab le 2009-09 -01 S26361-F35 54-E/L512 New SAS Modul ar RAID Controll er 6Gb/s - ...

メーカー Fujitsu カテゴリー Server

Fujitsu PRIMERGY RX300 S5のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PRIMERGY RX300 S5の取扱説明書
- Fujitsuの製品カード
- パンフレット
- またはFujitsu PRIMERGY RX300 S5の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fujitsu PRIMERGY RX300 S5の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fujitsu PRIMERGY RX300 S5の取り付け説明書、サービスマニュアル、簡易説明書、またはFujitsu PRIMERGY RX300 S5のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fujitsu PRIMERGY RX300 S5の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fujitsu PRIMERGY RX300 S5デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFujitsu PRIMERGY RX300 S5を使用するのを助ける技術的文書のことです。説明書は通常、全てのFujitsu PRIMERGY RX300 S5ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Fujitsuの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fujitsu PRIMERGY RX300 S5の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFujitsu PRIMERGY RX300 S5の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fujitsu PRIMERGY RX300 S5に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fujitsu PRIMERGY RX300 S5デバイスの基本機能を使うにあたってのヒント。 Fujitsu PRIMERGY RX300 S5のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fujitsu PRIMERGY RX300 S5に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFujitsu PRIMERGY RX300 S5のメーカー/サービスへの連絡先に関する情報。

Fujitsu PRIMERGY RX300 S5についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFujitsu PRIMERGY RX300 S5の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFujitsu PRIMERGY RX300 S5で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)