Radware VOYA-GRAND-PMHの取扱説明書

56ページ 7.73 mb
ダウンロード

ページに移動 of 56

Summary
  • Radware VOYA-GRAND-PMH - page 1

    September 25, 2012 7075-166 Page 1 R DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NO T DISCARD WARNING If the information in thes ...

  • Radware VOYA-GRAND-PMH - page 2

    Page 2 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert SerialNumber ModelName T estLab&Report Number Mfg Date Hearth&Home T echnologieswelcomesyoutoour tradition of excellence!  In choosing a Quadra-Fire appliance, you have our assurance of commitment to quali ...

  • Radware VOYA-GRAND-PMH - page 3

    September 25, 2012 7075-166 Page 3 VOY AGEUR GRAND Wood Insert R Congratulations ............................................................... 2 SampleofSafety/SerialNumberLabel ........................... 2 Warranty Policy ............................................................... 4-5 Section 1: Listing and Code Approvals  A. ...

  • Radware VOYA-GRAND-PMH - page 4

    Page 4 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purch ...

  • Radware VOYA-GRAND-PMH - page 5

    September 25, 2012 7075-166 Page 5 VOY AGEUR GRAND Wood Insert R 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the H ...

  • Radware VOYA-GRAND-PMH - page 6

    Page 6 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 1 Listing and Code Approvals The Quadra-Fire VOY AGEUR GRAND meets the U.S. Envi - ronmental Protection Agency’s 1990 particulate emission standards. A. Appliance Certication C. Glass Specications D. BTU & Efciency Specications ...

  • Radware VOYA-GRAND-PMH - page 7

    September 25, 2012 7075-166 Page 7 VOY AGEUR GRAND Wood Insert R 2 Op erating Instr uctions W ARNING! DO NOT operate appliance before reading and understanding operating instructions. Failuretooperateapplianceaccordingtooperatinginstructionscouldcausereorinjury . User Guide A. Y our Wood Appliance W ARNI ...

  • Radware VOYA-GRAND-PMH - page 8

    Page 8 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert B. Fire Safety T o provide reasonable re safety , the following should be givenseriousconsideration: 1. Install at least one smoke detector on each oor of your home to ensure your safety .  Th ...

  • Radware VOYA-GRAND-PMH - page 9

    September 25, 2012 7075-166 Page 9 VOY AGEUR GRAND Wood Insert R F . Burning Process In recent years there has been an increasing concern about air quality . Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have develope ...

  • Radware VOYA-GRAND-PMH - page 10

    Page 10 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert H. Air Controls 1. Start-Up Air Control The function of the Start-Up Air Control is to activate the AutomaticCombustionControlsystem(ACC). • Push the Start-Up Air Control all the way back until it stop ...

  • Radware VOYA-GRAND-PMH - page 11

    September 25, 2012 7075-166 Page 1 1 VOY AGEUR GRAND Wood Insert R CORRECT POSITION INCORRECT POSITIONS Improperbafeplacementmaycause:  • Overheatingofrebox  • Overheatingthechimney Bafemust beplacedproperly (seeinstructions) Replacebafeifdamagedormissing. W ARNING ...

  • Radware VOYA-GRAND-PMH - page 12

    Page 12 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert K. Building A Fire Beforelightingyourrstreintheappliance: 1.  Conrm the bafe and cera mic blanket are correctly  positioned. Theyshould beeven with thefront tubeand resting on all tubes. S ...

  • Radware VOYA-GRAND-PMH - page 13

    September 25, 2012 7075-166 Page 13 VOY AGEUR GRAND Wood Insert R M. W ood Fuel Moisture Seasoned Wood • Cutlogstosize • Splitto6inches(152mm)orlessindiameter • Airdrytoamoisturecontentofnotmorethan20% - Softwood-aboutninemonthstodry - Hard? ...

  • Radware VOYA-GRAND-PMH - page 14

    Page 14 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert O. Blower Operating Instructions 1. Initial (cold) startup: Open both controls fully by rais - ingtheBurnRate AirControl allthewayupuntilitstops and PUSH the Start-up Air Control back until it stops. ...

  • Radware VOYA-GRAND-PMH - page 15

    September 25, 2012 7075-166 Page 15 VOY AGEUR GRAND Wood Insert R R. Opacity (Smoke) Opacity is the measure of how cleanly your appliance is burning. Opacityismeasuredinpercent: • 100%opacityiswhenanobjectistotallyobscuredby thesmokecolumnfromachimney ,and • 0%opacitymea ...

  • Radware VOYA-GRAND-PMH - page 16

    Page 16 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert S. Quick Start Guide Note: Thesearegenericdrawingsandmaynotrepresent yourspecicmodel. Thestoveisreadyfor normal operation. 1 2 3 5 6 7 FIRST FIRE ITEMS NEEDED: 10PiecesofNewspaper ,10-20PiecesofDryKindling and ...

  • Radware VOYA-GRAND-PMH - page 17

    September 25, 2012 7075-166 Page 17 VOY AGEUR GRAND Wood Insert R • Frequency: When ash reaches the top of the brick covers (should not spill over covers).  Leave 1/4 inch (6mm) of ash in the bottom of the firebox. • By: Homeowner A. Disposal of Ashes • Placeashesinametal ...

  • Radware VOYA-GRAND-PMH - page 18

    Page 18 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert • Frequency: Asdesired • By: Homeowner • Cleanglasswitha non-abrasiveglasscleaner . Abrasive cleanersmayscratchandcauseglasstocrack. • If the deposits on the glass are not very heavy , normal glass cleaners? ...

  • Radware VOYA-GRAND-PMH - page 19

    September 25, 2012 7075-166 Page 19 VOY AGEUR GRAND Wood Insert R Note:  These are generic drawings and may not represent your specic model. Baffle Blanket Latch Cam Spacing Washers Bafe&Blanket OptionalBlower ChimneySystem Firebrick& AshRemoval Door&Glass Assemblies DoorHandle Frequency M ...

  • Radware VOYA-GRAND-PMH - page 20

    Page 20 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 4 T roubleshooting G u ide With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do experiencea problem,thistroubleshooting guidewillassist youoraqualied servicepersonin t ...

  • Radware VOYA-GRAND-PMH - page 21

    September 25, 2012 7075-166 Page 21 VOY AGEUR GRAND Wood Insert R 5 Ser vice Par ts Replacement A. Glass Replacement (Replace with 5mm ceramic glass only) 1.  Ensure that the re is out and the appliance is c ool to the touch. 2. Protect a tabl e or counter top with padding or towels. Protectyourhands? ...

  • Radware VOYA-GRAND-PMH - page 22

    Page 22 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert D. Blower Replacement 1. The grille on the blower access assembly is hinged.  Swing the grille downward to expose the 2 screws. Figure 22.1. 2. Remove the 2 screws from the blower access assembly and slide assembly away from ...

  • Radware VOYA-GRAND-PMH - page 23

    September 25, 2012 7075-166 Page 23 VOY AGEUR GRAND Wood Insert R Figure 23.1 F . Bafe & Ceramic Blanket Removal 1. Remove all ash from the rebox, and extinguish all hot embers before disposal into a metal container . 2.  It is easier to remove both bafe boards and ce ...

  • Radware VOYA-GRAND-PMH - page 24

    Page 24 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert G. T ube Channel Assembly Replacement Figure 24.3 RemovingTubeChannelAssembly 1. Removethe3rightsidebricks. 2. Remove the bafe protection channelby bending back the tabs using needle nose pliers located at the right and l ...

  • Radware VOYA-GRAND-PMH - page 25

    September 25, 2012 7075-166 Page 25 VOY AGEUR GRAND Wood Insert R 6 Getting Started Installer ’ s Guide A . Design and Installation Considerations 2.Priortoinstalling,determinethefollowing: • T ypeofchimneyconnectortobeused · single wall, 6 inch (152mm) diameter , stainless steel, or · double wall, 6 inc ...

  • Radware VOYA-GRAND-PMH - page 26

    Page 26 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert C. Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly . It can be strongest in lower levels of the house. Causesinclude: • Exhaustfans(kitchen,bath,etc.) • Rangeh ...

  • Radware VOYA-GRAND-PMH - page 27

    September 25, 2012 7075-166 Page 27 VOY AGEUR GRAND Wood Insert R Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Outside T ermination Cap Figure 27.1 E. Chimney T ermination Requirements Followmanufacturer ’ sinstructionsforclearance,s ...

  • Radware VOYA-GRAND-PMH - page 28

    Page 28 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 10 ft. (305cm) or more 3 ft. (91cm) Minimum Less than 10 ft. (305cm) 2 ft. (61cm) Minimum 3 ft. (91cm) Minimum W all or Parapet Flat Roof 3 ft. (91cm) Minimum Less than 10 ft. (305cm) 2 ft. (61cm) 3 ft. (91cm) Minimum 10 ft. (305cm) To Nearest Roofline 2 ft. (61cm) Pitched Roof These ...

  • Radware VOYA-GRAND-PMH - page 29

    September 25, 2012 7075-166 Page 29 VOY AGEUR GRAND Wood Insert R G. T ools And Supplies Needed H. Fire Safety T o provide reasonable re safety , the following should be givenseriousconsideration: 1. Install at least one smoke detector on each oor of your home to ensur ...

  • Radware VOYA-GRAND-PMH - page 30

    Page 30 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 7 Dimensions and Clearances A. Appliance Dimensions Figure 30.1 Top View Figure 30.2 Front View with Cast Surround NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) Figure 30.4 - Side View Without Optional Flue Adapter Overall Sizes A B Metal Surround w/Cast T rim-STD 42.5 in. ( ...

  • Radware VOYA-GRAND-PMH - page 31

    September 25, 2012 7075-166 Page 31 VOY AGEUR GRAND Wood Insert R B. Clearances to Combustibles, United States and Canada (UL and ULC) 32 5/8 (829mm) 22 1/2 (572mm) 43 (1092 mm) USA 38 1/4 CANADA 46 1/4 (1175mm) HEARTH EXTENSION (MINIMUM EMBER PROTECTION) 45 (1143 mm) USA 22 1/2 CANADA 24 1/2 (572mm) HEARTH EXTENSION (EMBER PROTECTION) FIREPLACE FR ...

  • Radware VOYA-GRAND-PMH - page 32

    Page 32 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 0 to 5 inches from bottom of unit, thermal prot ec- tion required. R v alue of 2.38. 5 inches or more from bottom of unit, ember protection only required B. Clearances to Combustibles, United States and Canada (UL and ULC) (cont.) Required Protection Suggested Protection NOTE: Keep A ...

  • Radware VOYA-GRAND-PMH - page 33

    September 25, 2012 7075-166 Page 33 VOY AGEUR GRAND Wood Insert R C. Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’ s) that will owin 1hour through1 square footof auniform mate - rial 1 inc ...

  • Radware VOYA-GRAND-PMH - page 34

    Page 34 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 8 Chimney Systems D. Masonry Chimney  • MustmeetminimumstandardsofNFP A 21 1.  • Musthaveatleast5/8inch (16mm)reclayliningjoined with refractory cement. NOTE: Installations into a clay flue without a stainless steel l ...

  • Radware VOYA-GRAND-PMH - page 35

    September 25, 2012 7075-166 Page 35 VOY AGEUR GRAND Wood Insert R UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Follow Manufacturer ’s Instructions on Insulation and Support For Zero or Other Non-Code Clearances, Follow Approved Liner Manufacturer ’s Specific Insulation Requirements: Different Clearances May Require Di ...

  • Radware VOYA-GRAND-PMH - page 36

    Page 36 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert F . Prefabricated Metal Chimney E. Metal Heat Circulating Masonry The chi mney can be new or existing, masonry or prefabricated andmustmeetthefollowingminimumrequirements:  • Must be minimum 6 inch (152mm) insi ...

  • Radware VOYA-GRAND-PMH - page 37

    September 25, 2012 7075-166 Page 37 VOY AGEUR GRAND Wood Insert R The following modications of factory-built replaces are permissible: • The replace must not be altered, except that the damper may be removed to accommodate a direct-connect starter pipe or chimney liner , • E xter ...

  • Radware VOYA-GRAND-PMH - page 38

    Page 38 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert Ovalizing round stainless steel liners to accommodate the linerpassingthroughthedamperregionofareplace isan allowable and acceptable practice. Ensure that the ovalization is minimized to the extent ...

  • Radware VOYA-GRAND-PMH - page 39

    September 25, 2012 7075-166 Page 39 VOY AGEUR GRAND Wood Insert R A. Outside Air Kit Installation Items Needed for Installation (not supplied)  • 4 inch ex aluminum pipe, or if using alternate material, then it shall be made from durable, non-combustible, heat resistant material up to 350 o F . Cutt ...

  • Radware VOYA-GRAND-PMH - page 40

    Page 40 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert C. Securing Stove Pipe/Liner to Flue Collar 1. There are 4 pre-drilledholes inthe uecollar 90degrees apart. Attachthe uecollar tothestove pipe/liner . Ifthe seal is questionable use stove mastic Figure 4 ...

  • Radware VOYA-GRAND-PMH - page 41

    September 25, 2012 7075-166 Page 41 VOY AGEUR GRAND Wood Insert R F . Standard Surround & T rim Kit Installation StandardSize:43in.Wx31in.H  LargeSize:51in.Wx34in.H 1. Lay surround face down on a protected surface to pre- vent scratching. 2. Using a 4 to 6 inches long ...

  • Radware VOYA-GRAND-PMH - page 42

    Page 42 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert 1. Remove contents from box being careful not to scratch or damage the cast trim pieces. 2 . Lay surround face down on a protected surface to prevent scratching. 3. Using a 4 to 6 inches long Phillips head screw driver attach  the side surrounds ...

  • Radware VOYA-GRAND-PMH - page 43

    September 25, 2012 7075-166 Page 43 VOY AGEUR GRAND Wood Insert R I. Blower Cord Installation on Left Side Theblowercord isshippedtobe installedontheright side ofthe appliance.Y oumay relocatethe cordso itis onthe left side. Overview:  Y ou are removing the ...

  • Radware VOYA-GRAND-PMH - page 44

    Page 44 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert Figure 44.1 Blower Access Assembly Grille hinges downward Remove Screws & Pull Access Assembly away from Insert Hold Down Bracket Remove Screws from Hold Down Bracket and Pull Blower Assembly Forward. Do not Remove Blower from the Hold Down Bracket Placement Slot Blower Control P ...

  • Radware VOYA-GRAND-PMH - page 45

    September 25, 2012 7075-166 Page 45 VOY AGEUR GRAND Wood Insert R 8. The power cord is now disconnected from the blower control plate. Pull the cord out through the right side of the appliance. Route Cord Through Retainer Clip Grommet 9. Insert the power cord throught the left side of the appliance in the hole contains ...

  • Radware VOYA-GRAND-PMH - page 46

    Page 46 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert Figure 47.1 NOTICE: •  Offsetsfromthevertical,not exceeding45°,areallowed per Section 905(a) of the Uniform Mechanical Code  (UMC). •  Of fsets greater than 45° are considered horizontal and? ...

  • Radware VOYA-GRAND-PMH - page 47

    September 25, 2012 7075-166 Page 47 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active Cast Iron W ood Insert - Large Part number list on following page. 8 1 3 4 5 10 11 6 8 12 13 14 16 17 18 19 20 21 23 24 7 22 15 9 2 09/12 VOY A-GRAND-MBK, VOY A-GRAND-PMH ...

  • Radware VOYA-GRAND-PMH - page 48

    Page 48 7075-166 September 25, 2012 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active IMPORT ANT : THISIS DA TEDINFORMA TION.Whenrequesting serviceor replacement partsforyourappliancepleaseprovidemodelnumberandserialnumber . All? ...

  • Radware VOYA-GRAND-PMH - page 49

    September 25, 2012 7075-166 Page 49 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active IMPORT ANT :THIS ISDA TEDINFORMA TION.Whenrequestingserviceorreplacement partsforyour appliancepleaseprovidemodelnumberand serialnumber . All ...

  • Radware VOYA-GRAND-PMH - page 50

    Page 50 7075-166 September 25, 2012 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active IMPORT ANT : THISIS DA TEDINFORMA TION. Whenrequesting serviceor replacement partsforyourappliancepleaseprovidemodelnumberandserialnumber . All? ...

  • Radware VOYA-GRAND-PMH - page 51

    September 25, 2012 7075-166 Page 51 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active IMPORT ANT :THIS ISDA TEDINFORMA TION.Whenrequestingserviceorreplacement partsforyour appliancepleaseprovidemodelnumberand serialnumber . All ...

  • Radware VOYA-GRAND-PMH - page 52

    Page 52 7075-166 September 25, 2012 Service Parts R VOY AGEUR - Grand Beginning Manufacturing Date: Oct 2012 Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliancepleaseprovidemodelnumberandserialnumber .? ...

  • Radware VOYA-GRAND-PMH - page 53

    September 25, 2012 7075-166 Page 53 VOY AGEUR GRAND Wood Insert R Date of Service Performed By Description of Service C. Service And Maintenance Log ...

  • Radware VOYA-GRAND-PMH - page 54

    Page 54 7075-166 September 25, 2012 R VOY AGEUR GRAND Wood Insert C. Service And Maintenance Log Date of Service Performed By Description of Service ...

  • Radware VOYA-GRAND-PMH - page 55

    September 25, 2012 7075-166 Page 55 VOY AGEUR GRAND Wood Insert R D. Homeowner ’ s Notes ...

  • Radware VOYA-GRAND-PMH - page 56

    Page 56 7075-166 September 25, 2012 R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , log onto www .quadrare.com DO NOT DISCARD THIS MANUAL CAUTION ? ...

メーカー Radware カテゴリー Lawn Mower

Radware VOYA-GRAND-PMHのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VOYA-GRAND-PMHの取扱説明書
- Radwareの製品カード
- パンフレット
- またはRadware VOYA-GRAND-PMHの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Radware VOYA-GRAND-PMHの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Radware VOYA-GRAND-PMHの取り付け説明書、サービスマニュアル、簡易説明書、またはRadware VOYA-GRAND-PMHのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Radware VOYA-GRAND-PMHの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Radware VOYA-GRAND-PMHデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRadware VOYA-GRAND-PMHを使用するのを助ける技術的文書のことです。説明書は通常、全てのRadware VOYA-GRAND-PMHユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Radwareの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Radware VOYA-GRAND-PMHの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRadware VOYA-GRAND-PMHの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Radware VOYA-GRAND-PMHに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Radware VOYA-GRAND-PMHデバイスの基本機能を使うにあたってのヒント。 Radware VOYA-GRAND-PMHのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Radware VOYA-GRAND-PMHに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRadware VOYA-GRAND-PMHのメーカー/サービスへの連絡先に関する情報。

Radware VOYA-GRAND-PMHについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRadware VOYA-GRAND-PMHの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRadware VOYA-GRAND-PMHで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)