  • Patton electronic 1080A-64 - page 1

    USER MANUAL MODEL 1080A and MODEL 1080A-64 Universal Synchronous & Asynchronous Short Range Modems SALES OFFICE (301) 975-1000 TECHNICAL SUPPO R T (301) 975-1007 http://ww w .patton.com Part #07M1080A-D Doc. #072041UD Revised 6/19/98 CERTIFIED An ISO-9001 Certified Company ...

  • Patton electronic 1080A-64 - page 2

    1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1080A Series components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unaut ...

  • Patton electronic 1080A-64 - page 3

    2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected by Patton's qualified technicians. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics T echnical Support at (301) 975-1007. 2.1 FEA ...

  • Patton electronic 1080A-64 - page 4

    Each Model 1080A Series SRM has three sets of eight switches, yielding 24 total DIP switches. The three sets will be referred to as S1, S2 and S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions. 3.2 CONFIGURA TION SWITCH SET “S1” The DIP switches on S1 set data rate, clock sou ...

  • Patton electronic 1080A-64 - page 5

    Switch S1-8: Carrier Control Method The setting for switch S1-8 determines whether the carrier is “constantly on” or “controlled by RTS”. This setting allows for operation in switched carrier , multipoint and/or hardware handshaking applications. S1-8 Setting Off Constantly on On Controlled by RTS 3.3 CONFIGURA TION SWITCH SET “S2” The ...

  • Patton electronic 1080A-64 - page 6

    3.4 CONFIGURA TION SWITCH SET “S3” The DIP switches on S3 set the anti-stream control, local loopback enable, remote loopback enable and receive (input) impedance levels for the Model 1080A Series. Factory default positions of Switch S3 are shown in the table below . Switches S3-1 & S3-2: Input Impedance The setting for Switches S3-1 and S3 ...

  • Patton electronic 1080A-64 - page 7

    Switch S3-6: RS-232 Initiation of Remote Loopback T est The setting for switch S3-6 determines whether or not the Model 1080A Series’ remote digital loopback test can be initiated by raising pin 21 on the RS-232 interface. S3-6 Setting On RS-232 initiation enabled Off RS-232 initiation disabled Switches S3-7 and S3-8: Anti-stream Control Switches ...

  • Patton electronic 1080A-64 - page 8

    4.1.1 T wo-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A Series Short Range Modem is prewired for a standard TELCO wiring environment. T o be sure you have the right wiring, use the table below as a guide. RJ-45 SIGNAL 1 -------------NC 2 -------------GND † 3 -------------RCV 4 -------------XMT 5 -------------XMT 6 ---------- ...

  • Patton electronic 1080A-64 - page 9

    4.2.1 Four-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A/1080A-64 Short Range Modem is prewired for a standard TELCO wiring environment. T o be sure you have the right wiring, use the table below as a guide. RJ-45 SIGNAL 1 -------------NC 2 -------------GND † 3 -------------RCV 4 -------------XMT 5 -------------XMT 6 -------- ...

  • Patton electronic 1080A-64 - page 10

    4.3 FOUR-WIRE, MUL TIPOINT INST ALLA TION Multipoint operation involves the connection of several terminals to one host port. In such an application, one local Model 1080A/1080A-64 is used as a master unit, and it is connected to several remote Model 1080A/1080A-64s that are acting as slaves. Up to 25 Model 1080A Series slaves may be connected to o ...

  • Patton electronic 1080A-64 - page 11

    5.1.4 The “Error” Indicators The “Error” indicator LED has three functions: A. When the 1080A Series unit is in test mode (green “T est” LED is lit), the error LED glows red when bit errors occur . B. When not in test mode (green “T est” LED is off), the error LED is used to indicate an RTS streaming condition. (See Section 5.2) for ...

  • Patton electronic 1080A-64 - page 12

    5.1.4.2 Reading The T est A. If line quality is good, “Error” LED on local modem will not light and “CD” LED will be red. On remote modem “Error” LED will not light and “CD” LED will light green. B. If flat cable is used or parts of the line are flat cable, “Error” LED on local modem will light red and “CD” LED will light gr ...

  • Patton electronic 1080A-64 - page 13

    A. Activate RDL. This may be done in two ways: First, by moving the front panel toggle switch UP to "Remote". Second, by raising pin 21 on the RS-232 interface (Note: Make sure DIP switch S3-6 is ON; and DIP switch S2-6 is OFF). B. Perform a BER (bit error rate) test on the system. C. If the BER test equipment indicates a fault, and the L ...

  • Patton electronic 1080A-64 - page 14

    APPENDIX B P A TT ON MODEL 1080A SERIES F ACT OR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 080510ACB .....................120V W all Mount AC Adapter 08059ACI ........................230V AC Adapter (No Power Cord) 07M1080A .......................Model 1080A Series User Manual 25 APPENDIX C P A TT ON MODEL 1080A SERIES CABLE R ...

  • Patton electronic 1080A-64 - page 15

    APPENDIX C P A TT ON MODEL 1080A SERIES INTERF ACE PIN ASSIGNMENT RS-232 FEMALE, D-SUB 25 CONNECTOR (DCE ORIENT A TION) 1- (FG) Frame Ground 2- (TD) T ransmit Data T o 1080A 3- (RD) Receive Data From 1080A 4- (RTS) Request to Send T o 1080A 5- (CTS) Clear to Send From 1080A 6- (DSR) Data Set Ready From 1080A 7- (SG) Signal Ground 8- (DCD) Data Carr ...

メーカー Patton electronic カテゴリー Network Card

Patton electronic 1080A-64のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1080A-64の取扱説明書
- Patton electronicの製品カード
- パンフレット
- またはPatton electronic 1080A-64の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Patton electronic 1080A-64の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Patton electronic 1080A-64の取り付け説明書、サービスマニュアル、簡易説明書、またはPatton electronic 1080A-64のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Patton electronic 1080A-64の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Patton electronic 1080A-64デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPatton electronic 1080A-64を使用するのを助ける技術的文書のことです。説明書は通常、全てのPatton electronic 1080A-64ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Patton electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Patton electronic 1080A-64の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPatton electronic 1080A-64の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Patton electronic 1080A-64に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Patton electronic 1080A-64デバイスの基本機能を使うにあたってのヒント。 Patton electronic 1080A-64のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Patton electronic 1080A-64に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPatton electronic 1080A-64のメーカー/サービスへの連絡先に関する情報。

Patton electronic 1080A-64についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPatton electronic 1080A-64の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPatton electronic 1080A-64で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)