    1 W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU SMELL GAS: • Do not try to light any applianc ...

  • A.O. Smith 750 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the inst allation, use, and servicing of this boiler . Many safety-related messages and instructions have been provided in this manual and on your own boiler to warn you and others of a potential injury hazard. Read and obey all safety messages an ...

  • A.O. Smith 750 - page 3

    3 GENERAL SAFETY ...

  • A.O. Smith 750 - page 4

    4 SAFE INST ALLA TION, USE, AND SERVICE ....................................................................................................................................... 2 GENERAL SAFETY ............................................................................................................................... ............................. ...

  • A.O. Smith 750 - page 5

    5 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in p art for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven ( ...

  • A.O. Smith 750 - page 6

    6 CONNECTION DIAGRAM ...

  • A.O. Smith 750 - page 7

    7 ...

  • A.O. Smith 750 - page 8

    8 SCHEMA TIC DIAGRAM VB/VW-500, 750 & 1000 SCHEMA TIC DIAGRAM ...

  • A.O. Smith 750 - page 9

    9 LIGHTING & OPERA TION INSTRUCTIONS FOR MODELS VB/VW 500, 750 AND 1000: ...

  • A.O. Smith 750 - page 10

    10 children to use a hot water t ap, or to draw their own bath water . Never leave a child or disabled person unattended in a bathtub or shower . The boiler should be located in an area that is inaccessible to the general public. T ABLE 1. Risk of Scalds. T emperature Time to Produce 2nd & 3rd Setting Degree Burns on Adult Skin Over 170°F (77? ...

  • A.O. Smith 750 - page 11

    11 sequences and safety features associated with a gas ignition control system. The system continuously performs various diagnostic test s to verify proper appliance and control operation. Should an unsafe condition occur , the control will shut down the burner and display a red service light as well as indicate the cause of the error on the displa ...

  • A.O. Smith 750 - page 12

    12 the temperature is less than the operating setpoint minus the differential temperature and the thermostat input is closed then a call for heat is established and the system shift s to the run mode (green "Running" LED turns on). 5. The heating sequence begins by applying power to the pump. 6. After a few seconds the blower is turned on ...

  • A.O. Smith 750 - page 13

    13 waits for a heat request (determined by the Thermost at or controlling probe input s). All outputs are o f f i n this st ate except that if the Post-Circulate time i s set to continuous, th e pump will be on. When the heat request i s received, the system moves to the Pre-Circulate state. • Pre-Circulate: The yellow LED is turned off and the g ...

  • A.O. Smith 750 - page 14

    14 if the blower prover does not activate after 15 seconds. This time allows the blower relay to activate, the blower to come up to speed, and the response from the blower prover to be filtered. • User Settings Screen: Each setpoint or user setting has either a limited selection of values, or a limited range of values. The Up/Down keys are used t ...

  • A.O. Smith 750 - page 15

    15 kBtu rating of the boiler (0 to 5750kBtu in 10kBtu increments) The sof tware revision level of the MCB. • Current Error Screen: Displays the last error that the system has detected plus a time stamp of when the error occurred. (The time st amp is based on the elapsed hours value at the time the error occurred. It is displayed in hours and minu ...

  • A.O. Smith 750 - page 16

    16 TROUBLESHOOTING IGNITION SYSTEM Fault Messages and Lockout S tatus (* = stage number: 1, 2, 3, or 4) FAUL T DISPLA YED DESCRIPTION RED LED LOCKOUT “Display Fail” Communications with UIM interrupted Continuous Auto Reset Check communication cable to UIM. T ry moving to other Internal Communications connector on MCB. Also check the connectors ...

  • A.O. Smith 750 - page 17

    17 This is a pre-mix burner system. The flame is not supposed to be directly on the burner . The flame should be just above the burner deck approximately 1/8” and blue in color , see illustration. BURNER FLAMES Visually check flame characteristics through the view port located on the top head of the boiler . The “Burner Flames” illustration s ...

  • A.O. Smith 750 - page 18

    18 Any safety devices including low water cutoffs used in conjunction with this boiler should receive periodic (every six months) inspection to assure proper operation. A low water cutoff device of the float type should be flushed every six months. Periodic checks, at least twice a year , should be made for water leaks. More frequent inspections ma ...

  • A.O. Smith 750 - page 19

    19 lines with air or water and clear or replace the blocked portions of the line as necessary . Note that areas of the drain line which include a sag or low spot in the line will also form a condensate trap which can be removed by levelling the tube and does not indicate a blocked system. Inspect the metal vent drain and vent collector drain connec ...

  • A.O. Smith 750 - page 20

    20 NOTES ...

  • A.O. Smith 750 - page 21

    ...

  • A.O. Smith 750 - page 22

    22 NOTES ...

  • A.O. Smith 750 - page 23

    23 LIMITED W ARRANTY A. O. Smith Corporation, the warrantor , extends the following LIMITED WARRANTY to the owner of this boiler: 1. If within TEN years after initial inst allation of the boiler, a heat exchanger or gas burner shall prove upon examination by the warrantor to be defective in material or workmanship, the warrantor , at his option wil ...

  • A.O. Smith 750 - page 24

    24 500 T ennessee W altz Parkway , Ashland City , TN 37015 Phone: 800-433-2545 w w w .hotwater .com E-Mail: p art s@hotwater .com ...

メーカー A.O. Smith カテゴリー Water Heater

A.O. Smith 750のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 750の取扱説明書
- A.O. Smithの製品カード
- パンフレット
- またはA.O. Smith 750の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A.O. Smith 750の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A.O. Smith 750の取り付け説明書、サービスマニュアル、簡易説明書、またはA.O. Smith 750のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A.O. Smith 750の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A.O. Smith 750デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA.O. Smith 750を使用するのを助ける技術的文書のことです。説明書は通常、全てのA.O. Smith 750ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A.O. Smithの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A.O. Smith 750の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA.O. Smith 750の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A.O. Smith 750に関してこのドキュメントで見つけることができる全てのヒントの目次
3. A.O. Smith 750デバイスの基本機能を使うにあたってのヒント。 A.O. Smith 750のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A.O. Smith 750に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA.O. Smith 750のメーカー/サービスへの連絡先に関する情報。

A.O. Smith 750についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA.O. Smith 750の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA.O. Smith 750で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)