Lumex Syatems LF1050の取扱説明書

16ページ 0.48 mb
ダウンロード

ページに移動 of 16

Summary
  • Lumex Syatems LF1050 - page 1

    DSC250 SCALE for LF1050 and LF1090 Lifts USER MANUAL Read these instructions before using the Lumex Lift Scale. Save these instructions for future reference. The most current version of these instructions can be found online at www .grahameld.com.  ...

  • Lumex Syatems LF1050 - page 2

     GF Health Products, Inc. is not r esponsible for typographical errors. For the most updated and current information on packaging, warranties, products and specications, including the most current version of these instructions, please visit our website at www .grahameld.com. Graham-Field and Lumex are r egistered trademarks of GF Health Pr ...

  • Lumex Syatems LF1050 - page 3

     INTRODUCTION Safety W ARNING: Important! Read and understand these instructions before assembling or using the Lumex Lift Scale. If you do not understand any part of these warnings or instructions, contact a healthcare professional for direction in the use of this product. If the Lift Scale is not properly assembled, personal injury and damage ...

  • Lumex Syatems LF1050 - page 4

     W ARNING: This product has a maximum weight capacity of 600 lb (300 kg). If patient weight exceeds maximum weight capacity , the scale will designate overload by displaying “-oL-”. DO not exceed the maximum weight capacity of the lift being used for measurement. W ARNING: California Proposition 65 W ARNING: This product contains a chemical ...

  • Lumex Syatems LF1050 - page 5

     ASSEMBL Y INSTRUCTIONS Components Ensure all components shown below ar e included in the package. Item Qty Picture Description 1 1 Scale 2 2 Bushing 1220 3 2 Bushing 1020 4 1 Universal bracket 5 2 Pin 6 2 Key ring ...

  • Lumex Syatems LF1050 - page 6

     1. Follow these instructions to attach the scale to the LF1050 or LF1090 Lift using the included mounting har dware. Do not use any other mounting har dwar e than that pr ovided. 2. Keep the scale in a cool, dr y place. If operation temperature is over 104°F (40°C), the tolerance will not be accurate within 0.2 lb (0.1 kg). The storage temper ...

  • Lumex Syatems LF1050 - page 7

     Installation on Lumex LF1050 Patient Lift Install on Lumex LF1050 Patient Lift as shown above. Item numbers shown are those listed in the table shown on page 5. W ARNING: Ensure scale is securely mounted as shown above before proceeding. ...

  • Lumex Syatems LF1050 - page 8

     Installation on Lumex LF1090 Patient Lift Install on Lumex LF1090 Patient Lift as shown above. Item numbers shown are those listed in the table shown on page 5. W ARNING: Ensure scale is securely mounted as shown above before proceeding. ...

  • Lumex Syatems LF1050 - page 9

     OPERA TION INSTRUCTIONS Keyboard Illustration Display Illustration Instructions for Use 1. Place sling to be used onto spreader bar without patient/resident/user . 2. Press the On/Zero button on the scale faceplate to zer o-out the weight of the sling (this weight will remain zer oed out until the Of f button is pressed). 3. Press the Kg/lb but ...

  • Lumex Syatems LF1050 - page 10

     4. Carefully lift the patient/r esident/user in the sling and perform the lift so that all of the weight is supported by the lift. Stabilize the movement of the sling after lifting. 5. W eight will display on the scale. Pr ess the Operate/Hold button to hold the weight displayed. T o reset the scale to zer o, pr ess the Operate/Hold button a ...

  • Lumex Syatems LF1050 - page 11

     MAINTENANCE Cleaning As needed, wipe scale gently , using mild soap or a mild disinfectant. s NOTICE: DO NOT wash under water pressure or steam clean. DO NOT use solvents, abrasive cleaners, or scouring pads to clean scale. Battery Replacement When the low batter y indicator ( ) appears in the display’ s right corner , replace the battery: ...

  • Lumex Syatems LF1050 - page 12

     SPECIFICA TIONS Model Number DSC250 Capacity 600 lb (300 kg) Resolution 1/3,000 ±1d Division 0.2 lb (0.1 kg) Power Source 9V alkaline battery x 1 T emperature Operating 32°F ~ 104°F (0°C ~ 40°C) Storage 32°F ~ 158°F (0°C ~ 70°C) Dimensions (W x H x D) 3.54 x 2.83 x 2.17 in. (90 x 72 x 55 mm) Product Weight 24 oz ± .35 oz / 1.5 lb ? ...

  • Lumex Syatems LF1050 - page 13

     LIMITED W ARRANTY GF Health Products, Inc. (“Graham-Field”) guarantees the Lumex DSC250 Lift Scale free fr om defects in materials and workmanship under normal use for two years from the date of pur chase. If a pr oduct is deemed to be under warranty , GF Health Products, Inc. shall pr ovide, at its option, (1) replacement of any defecti ...

  • Lumex Syatems LF1050 - page 14

     relied on any r epresentation, assertion, guarantee, warranty , collateral contract or other assurance, except those set out in this document. ...

  • Lumex Syatems LF1050 - page 15

     NOTES ...

  • Lumex Syatems LF1050 - page 16

    GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, GA 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.com © 2013 GF Health Products, Inc. Made in T aiwan ...

メーカー Lumex Syatems カテゴリー Building Set

Lumex Syatems LF1050のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LF1050の取扱説明書
- Lumex Syatemsの製品カード
- パンフレット
- またはLumex Syatems LF1050の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lumex Syatems LF1050の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lumex Syatems LF1050の取り付け説明書、サービスマニュアル、簡易説明書、またはLumex Syatems LF1050のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lumex Syatems LF1050の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lumex Syatems LF1050デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLumex Syatems LF1050を使用するのを助ける技術的文書のことです。説明書は通常、全てのLumex Syatems LF1050ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lumex Syatemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lumex Syatems LF1050の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLumex Syatems LF1050の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lumex Syatems LF1050に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lumex Syatems LF1050デバイスの基本機能を使うにあたってのヒント。 Lumex Syatems LF1050のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lumex Syatems LF1050に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLumex Syatems LF1050のメーカー/サービスへの連絡先に関する情報。

Lumex Syatems LF1050についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLumex Syatems LF1050の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLumex Syatems LF1050で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)