Carrier Access 52Pの取扱説明書

16ページ 0.89 mb
ダウンロード

ページに移動 of 16

Summary
  • Carrier Access 52P - page 1

    52C SERIES 1•800• 894•6449 (in USA and Can ada) F or Ser vice/T echnical As sistance 1•800•830•8600 (Me xico) OWNER’S MANUAL P ACKAGED TERMINAL AIR CONDIT IONERS AND HEA T PUMPS 7,000-15,0 00 Btuh CONTENTS Page GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 UNIT IN SPECTIO N . . . . . . . . . . ...

  • Carrier Access 52P - page 2

    2 GENERAL Thank you for choosing Carrier! You can feel confident in your se lection becaus e the same prid e in craftsman- ship a nd engi neering knowled ge that g oes int o Carrie r equipme nt at the Astrod ome in Texa s, the Sisti n e Chapel in Rome, the US Capitol Hall of Congress, and thousa nds of other install ations worldw ide has gone into ...

  • Carrier Access 52P - page 3

    3 To in stall the front pan el follow the pr ocedure ou tlined below: 1. Firmly g rasp bottom of front panel on both si des. 2. Hold front pan el at a 45 deg ree angle to unit. Be sure front panel is ce ntered with front of uni t. 3. Conn ect top of front p anel to par tition rai l on top of unit. 4. Gent ly lower front panel onto ch assis, ensurin ...

  • Carrier Access 52P - page 4

    4 ELECTRICAL DA T A Be sure that your o utlet mat ches the appropri ate blade con figuration o f the supp lied plug and that it is within reach of the service cord. A hardwire kit is available as an accessory to change cord-connected units to hardwired units. (See Acce s sories ta ble on page 14.) ALL UNITS ■ WIRE SIZ E — Use recommended wire s ...

  • Carrier Access 52P - page 5

    5 INST ALLA TION CHASSIS INST ALLA TION Units ar e shipped wi thout a sleeve. I n applicati ons where uni t is a replace ment, it is re commended that a Carrier sleeve b e us ed. The 5 2C and 52P units can retrofit General Ele ctric, Aman a and Trane sleeve s/ grilles (be sure ou tdoor gr ille is instal led on the sleev e). A retrofit kit with in s ...

  • Carrier Access 52P - page 6

    6 ■ INST ALL CHASSIS IN SLEEVE (Se e Figures 6 to 9) 1. Inspect foam gaskets ( t op , bot tom, both sid es) on chassi s. Replace foam ga skets i f t orn or missing. 2. Remove shipping tape from vent door. See Figure 7. 3. Lif t chassi s level wi th wall sl eeve. 4. Sl ide chassi s into wal l sleev e until fo am gaskets rest f irmly against fron t ...

  • Carrier Access 52P - page 7

    7 W ALL THERMOST A T INST ALLA TION The follow ing instruction s apply to RC a n d RP units onl y. NOTE: Carrier thermostats are recommended. See Accessories section. ■ INST ALL THERMOST A T — All remote control units. 1. Chec k to be su re power to unit is d isconnecte d. 2. Remove terminal board cover from control box cover by removing screw ...

  • Carrier Access 52P - page 8

    8 OPERA TION COMFOR T CONTROLS ■ ADJUST AIRFLOW DIRECTION — The disc harge air grille is mounted on the fron t panel so th at the a ir discharges forward. If upward discharge is required , remove the grille by removing screws o n back of front panel. Ro tate grille 180 degrees and rein stall on the fron t pa n el . ■ AD JUST VE NT — The ven ...

  • Carrier Access 52P - page 9

    9 OPERA TING CONTROLS The foll owing controls a r e located on the front o f the control b ox door, under fron t panel. To obtain access t o operating cont rols, remove the unit f ront panel as shown on page 2. See Figure 14. ■ F AN CYCLE SWITCH — (Not availabl e on RC or RP units.) This allows the fan to operate in t wo modes: CON (Continuous) ...

  • Carrier Access 52P - page 10

    10 CARE AND MAINTENANCE In or der to maintai n prop er per forma nce of your pa ck- aged terminal air conditioner or heat pump, it is very importan t that the fan and ou tdoor coil, the blower wheel, blower scro ll, electric hea ter, and al l drain pa s- sages ar e thoroughl y cleaned at least o nce per year. Carrier recommends that as a minimum, t ...

  • Carrier Access 52P - page 11

    11 EXTERNAL P AR TS ■ EXTERNAL P AR TS in clude the polyme r sleeve and grilles. The sleev e manufacturer recommends cleaning the surface, in cluding the grille s, with household detergent and water. INTERNAL P AR TS ■ INT ERNAL P AR TS should be c leaned at least on ce duri ng the ye ar. The outdoo r vent fi lter sh ould be cleaned at least on ...

  • Carrier Access 52P - page 12

    12 PREVENT A TIVE MAINTENANCE Preventativ e maintenance is essenti a l to prope r unit operatio n, efficiency and longevity. To assure equip- ment opera t e s pro perly it must be properly main - taine d. Equipme nt operati o n shoul d be checked and verified several times during each ye ar. During regular uni t insp ection and maintenance, fol- lo ...

  • Carrier Access 52P - page 13

    13 TROUBLESHOOTING NO TES: 1. If circuit breaker is t ripped or fuse is b lown more than once, contact a qualif i ed elect rician. 2. If unit is installed where condensation dr ainage could dr ip in an undes i rable location, an accessor y drain kit should be installed and connected to dr ain syst em. POSSIBLE CA USES SOLUTIONS UNIT DOES NO T ST AR ...

  • Carrier Access 52P - page 14

    14 ACCESSORIE S *Extend ed metal wall sleev e also available in 26 in. and 28 in. dept h. † Custom colors are also a v ailable. A CCESSOR Y FORM NUMBER P ART NUMBER DESCRIPTION Wall S leeves 52S-48 SI W AL L-SLEEVE-1P K Non-I nsulated Plasti c W all Sleev e, 1 per pack W ALL-S LEEVE-9 PK Non-In sul ated Pla sti c W all Sl eev e, 9 p er pac k SLEE ...

  • Carrier Access 52P - page 15

    15 Carrier P ackaged T er m inal Air Condit ioner W arra nty FULL ONE-YEAR W ARRANTY — Durin g the first year after pu rchase, CARRIER will, through its auth oriz ed independent ser vicing dealers or ser vice stations*, and free of ch arge to the use r or subsequ ent users, repair o r replace any par ts whic h are defective in mater ial or workma ...

  • Carrier Access 52P - page 16

    Copyright 20 02 Carri er Cor poration Manufa cturer re serve s the ri ght to dis continue , or chan ge at a n y t ime, s pecifica tions or design s without notice and withou t inc urring obligations. PC 132 Catalog No . 535 -20038 Pr inted in Mexico Form 52C,P-1SO Pg 16 2-02 Replace s: 52C-1SI 52P- 1SO Book 1 4 T ab 9a 11a ...

メーカー Carrier Access カテゴリー Air Conditioner

Carrier Access 52Pのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 52Pの取扱説明書
- Carrier Accessの製品カード
- パンフレット
- またはCarrier Access 52Pの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Carrier Access 52Pの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Carrier Access 52Pの取り付け説明書、サービスマニュアル、簡易説明書、またはCarrier Access 52Pのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Carrier Access 52Pの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Carrier Access 52Pデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCarrier Access 52Pを使用するのを助ける技術的文書のことです。説明書は通常、全てのCarrier Access 52Pユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Carrier Accessの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Carrier Access 52Pの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCarrier Access 52Pの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Carrier Access 52Pに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Carrier Access 52Pデバイスの基本機能を使うにあたってのヒント。 Carrier Access 52Pのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Carrier Access 52Pに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCarrier Access 52Pのメーカー/サービスへの連絡先に関する情報。

Carrier Access 52Pについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCarrier Access 52Pの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCarrier Access 52Pで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)