    EE542-1 Z I Installation Manual Smart Energy Programmable Thermostat + Energy Monitor ...

  • Emerson EE542-1Z - page 2

    1 2 3 3 4 6 9 14 17 19 20 - 22 Back Cover Contents Introduction Getting Started Installing the Thermostat Quick Guide Step 1: Remove the Old Thermostat Step 2: Mount the New Thermostat Step 3: Configure the Thermostat Step 4: Check Thermostat Operation Step 5: Pair De vice to Home Area Network Step 6: V erify W ireless Connectivity Wiring Chart Wir ...

  • Emerson EE542-1Z - page 3

    Introduction • About this Guide • System Compatibility 1 This guide describes how to install and configur e your new Smart Energy thermostat. This product r eplaces most thermostats, including those that work with: • Standar d Heat and Cool Systems • T wo-Stage H eat and T wo-Stage Cool Systems • Air Source Heat P ump (with Aux. or Emerge ...

  • Emerson EE542-1Z - page 4

    Getting Started N ote: This product r equires a 24v AC power supply via the C terminal for operation. • Thermostat (1) • Wall anchors (2) • Mounting scr ews (2) Required Items • Flat blade scr ewdrivers – 1 large and 1 micro tip • Hand or pow er drill with 3/16 inch drill bit • Wire strippers • Level (optional) Required T ools Befor ...

  • Emerson EE542-1Z - page 5

    3 T o prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or cir cuit breaker box until installation is complete. CA UTION Quick Guide • T urn of f power at the breaker . • Remov e cover from old ther mostat to expose wires. • Document which wir es go to which terminals using the table on the bac ...

  • Emerson EE542-1Z - page 6

    4 T o prevent electrical shock and/or equipment damage, disconnect electr ic power to system at main fuse or cir cuit breaker box until installation is complete. CA UTION This product does not contain mercury . However this product may r eplace a product that contains mercury . Mer cury and products containing mercury must not be discarded in house ...

  • Emerson EE542-1Z - page 7

    5 Remov e the Old Thermostat Important: Do not let wires fall back into the wall. 1. R emove the front co ver of the old thermostat. 2 . With wir es still attached, remo ve wall plate from the wall by loosening the scr ews. If the old thermostat has a wall mounting plate, remo ve both the thermostat and the wall mounting plate. 3. I dentify each wi ...

  • Emerson EE542-1Z - page 8

    O/B G W/E W2 L Y2 Y1 RC RH C C 6 T ake care when securing and routing wir es so they do not shor t to adjacent terminals or rear of ther mostat. P ersonal injury and/or property damage may occur . CA UTION STEP 2. Mount the Ne w Thermostat 1. U npack the thermostat and separate the mounting plate from the thermostat. R emove the packing material fr ...

  • Emerson EE542-1Z - page 9

    O/B G W/E W2 L Y2 Y1 RC RH C C 7 3. Once you have established the desir ed location of the thermostat, use a pencil, and the wall plate as a template, to mark the location of the mounting holes on your wall. 4. Mo ve wall plate out of the way and drill two holes using a 3/16" drill bit. 5. F eed the thermostat wires through the r ectangular ho ...

  • Emerson EE542-1Z - page 10

    8 Connect wires as follows: • If necessary , strip insulation about 3/8 inch from the end of the wir e. • U se the table you previously filled out on the back of the installation manual (or the wir ing chart on page 20) to locate the corr ect terminal for each wire connection. • Bend the wir e slightly , inser t the wir e under the contact pl ...

  • Emerson EE542-1Z - page 11

    9 STEP 3. Configure the Thermostat 1. T o enter the INST ALLA TION MENU, simultaneously press and hold and for 3 seconds. Y ou will be greeted with the following disclaimer . T o enter the INST ALL A TION MENU, press Y es. 2. While in the INST ALLA TION MENU, and scroll the cursor up and do wn respectively , the goes back one menu level and the and ...

  • Emerson EE542-1Z - page 12

    NO TE: The pr esence of a wir e in the W2 terminal is a good indication that the user has two-stage equipment located inside the house (furnace, air handler , or boiler). The pr esence of a wire in the Y2 terminal is a good indication that the homeo wner has two-stage equipment located outside the house (air conditioner or heat pump). 10 If the sys ...

  • Emerson EE542-1Z - page 13

    11 3. About This Device Installation > About This Device By properly identifying the type of equipment on pr emise in the HV AC Equipment Setup portion of the installation menu, no further modifications to the thermostat are r equired. Ho wever , if you want to further customize specific attributes you may do so via the Advanced HV AC Options me ...

  • Emerson EE542-1Z - page 14

    This feature is intended to help pr otect the compressor from short cycling. Some newer compr essors already have a time delay built in and do not requir e this feature. Y our compressor manufacturer can verify if the lockout featur e is already present in their system. Options for this menu item include: • OFF: (Default) N o compressor wait time ...

  • Emerson EE542-1Z - page 15

    This configures whether the O/B terminal for the heat pump r eversing valve will be energized during cool (O) or heat (B) mode. 4D. O/B Configuration Installation > Advanced HV AC Options > O/B Configuration If the user has multi-stage equipment and would like to have the ability to rapidly heat or cool on command, then set this feature to th ...

  • Emerson EE542-1Z - page 16

    STEP 4. Check Thermostat Operation T o prevent compr essor and/or proper ty damage, DO NO T operate the cooling system if the outdoor temperature is belo w 55° F . CA UTION Once you have installed your new ther mostat, you need to check that the fan, cooling system, and heating system are all operating properly . If you ar e still in the INST ALLA ...

  • Emerson EE542-1Z - page 17

    Check the heating system 1 . Pr ess Heating / Cooling Mode key one or mor e times to select HEA T mode. If the auxiliary heating system has a standing pilot, be sure to light it. 2. P ress the to adjust thermostat setting to 1° abo ve room temperature. The heating system should begin to operate. NO TE: If the system is configured as a heat pump an ...

  • Emerson EE542-1Z - page 18

    Check the back-up heating system (heat pump systems only): The Back U p Heat bypasses the heat pump to use the heat source wired to E & W2 terminals of the thermostat. Back U p is typically used when compressor operation is not desir ed, the user prefers to utilize the back-up heat only , or the compressor is not able to satisfy the demand for ...

  • Emerson EE542-1Z - page 19

    STEP 5. P air Device to a Home Area Network Installation > N etwork Settings > Installation I nformation F rom the NETWORK SETTINGS screen, highlight INST ALL A TION INFORMA TION and press . T o pair this device to a network coordinator (such as a smart meter or IP gateway), follow these steps: STEP 1 During the pairing pr ocess defined by yo ...

  • Emerson EE542-1Z - page 20

    Once you have pro vided the two numbers above you will be asked to send a “Join ” request from the thermostat. T o do so go to the NETWORK CONNECTION screen. STEP 3 P ress the CONNECT key . STEP 4 Y ou may have to wait up to 3 minutes for the pairing process to be completed. During that time you will see the following content on the display: ST ...

  • Emerson EE542-1Z - page 21

    STEP 6. V erify Wireless Connectivity The following scr een in the NETWORK SETTINGS area of the installation menu will serve as fur ther confirmation of network connectivity: STEP 1 On the home screen, a wir eless icon will also confirm that the unit is in fact connected to a network coordinator . STEP 2 If a connection is not made, the words “NO ...

  • Emerson EE542-1Z - page 22

    NO TE: This product requir es 24V power supply via the C terminal to operate. W iring Chart O/B G W/E W2 L Y2 Y1 RC RH C O/B G W/E W2 L Y2 Y1 RC RH C NO TE: No thermostat installation uses all of the wir es shown belo w . In most cases, between 5 and 6 terminals ar e wired. The remaining terminals will not be used. * F AIL URE T O REMOVE PR OVIDED ...

  • Emerson EE542-1Z - page 23

    21 Y1 Conventional H VA C Cool Mode Stage 1 Compressor Contactor Heat P ump Y2 Cool Mode Stage 2 Compressor Stage 2 W/E Heat M ode Stage 1 A UX Heat Stage 1 W2 Heat M ode Stage 2 A UX Heat Stage 2 O/B – Reversing V alve The following terminals on the thermostat M ounting Plate are wir ed according to the type of HV A C system connected to and the ...

  • Emerson EE542-1Z - page 24

    37-7301C W iring T able Old T erminal W , W1, 4, E W/E Y , Y1 Y1 G G R C, R R C RH, 5, R5 RH W2, W-U W2 Y2 Y2 C C L, F L O, B O/B Wir e Color N ew T erminal 2013 Emerson, Emerson Climate Technologies are trademarks of Emerson Electric Co. or one of its affiliated companies. ©20 1 3 Emerson Electric Co. All rights reserved. ...

メーカー Emerson カテゴリー Thermostat

Emerson EE542-1Zのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EE542-1Zの取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson EE542-1Zの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson EE542-1Zの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson EE542-1Zの取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson EE542-1Zのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson EE542-1Zの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson EE542-1Zデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson EE542-1Zを使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson EE542-1Zユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson EE542-1Zの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson EE542-1Zの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson EE542-1Zに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson EE542-1Zデバイスの基本機能を使うにあたってのヒント。 Emerson EE542-1Zのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson EE542-1Zに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson EE542-1Zのメーカー/サービスへの連絡先に関する情報。

Emerson EE542-1Zについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson EE542-1Zの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson EE542-1Zで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)