Miller Electric HF-251-2の取扱説明書

40ページ 0.93 mb
ダウンロード

ページに移動 of 40

Summary
  • Miller Electric HF-251-2 - page 1

    HF-251D-1 And HF-251-2 Processes Description TIG (GT A W ) W elding OM-611 096 556U January 2004 High Frequency Arc Starter Visit our website at www.MillerWelds.com ...

  • Miller Electric HF-251-2 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric HF-251-2 - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . ...

  • Miller Electric HF-251-2 - page 4

    ...

  • Miller Electric HF-251-2 - page 5

    OM-61 1 Page 1 Return T o T able Of Contents SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _8/03 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of sym ...

  • Miller Electric HF-251-2 - page 6

    OM-61 1 Page 2 Return T o T able Of Contents Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly of f from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or ...

  • Miller Electric HF-251-2 - page 7

    OM-61 1 Page 3 Return T o T able Of Contents 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and pro ...

  • Miller Electric HF-251-2 - page 8

    OM-61 1 Page 4 Return T o T able Of Contents 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 (phone: 305-443-9353, website: www .aws.org). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Contain ...

  • Miller Electric HF-251-2 - page 9

    OM-61 1 Page 5 Revenez à la table des matières SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE A V ANT UTILISA TION som_fre 8/03 2-1. Signification des symboles Signifie « Mise en garde. Faire preuve de vigilance. » Cette procédure présente des risques identifiés par les symboles adjacents aux directives. Y Identifie un message de sécurit ...

  • Miller Electric HF-251-2 - page 10

    OM-61 1 Page 6 Revenez à la table des matières Le rayonnement de l’arc génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) suscep- tibles de causer des brûlures oculaires et cutanées. Des étincelles sont projetées pendant le soudage. LES RA YONS DE L ’ARC peuvent c au - ser des brûlures oculaires et cuta- n? ...

  • Miller Electric HF-251-2 - page 11

    OM-61 1 Page 7 Revenez à la table des matières 2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de l’appareil. Risque D’INCENDIE OU D’EXPLO- SION D Ne pas placer l’appareil sur une surface inflam- mable, ni au−dessus ou à proximité d’elle. D Ne pas installer l’appareil à proximité de produ ...

  • Miller Electric HF-251-2 - page 12

    OM-61 1 Page 8 Revenez à la table des matières 2-4. Principales normes de sécurité Safety in W elding, Cutting, and Allied Processes, norme ANSI Z49.1, de l’American W elding Society , 550 N .W . LeJeune Rd, Miami FL 33126 (téléphone : (305) 443−9353, site Web : www .aws.org). Recommended Safe Practices for the Preparation for W elding an ...

  • Miller Electric HF-251-2 - page 13

    OM-61 1 Page 9 Return T o T able Of Contents SECTION 3 − INST ALLA TION 3-1. Specifications W elding Circuit Rat- Input Powe r Cord With T ype Of Input Power Dimensions W eight Circuit Rat- ing Cord With Plug 1 15 V olts 230 V olts Height Width Length 1 15 V olts 230 V olts 250 Amperes At 60% Duty Cycle 10 ft (3 m) 1 15 V olts AC Single-Phase 50/ ...

  • Miller Electric HF-251-2 - page 14

    OM-61 1 Page 10 Return T o T able Of Contents Obtain gas cylinder and chain to running gear , wall, or other station- ary support so cylinder cannot fall and break of f valve. 1 Cap 2 Cylinder V alve Remove c ap, stand to side of valve, and open valve slightly. Gas flow blows dust and dirt from valve. Close valve. 3 Cylinder 4 Regulator/Flowmeter I ...

  • Miller Electric HF-251-2 - page 15

    OM-61 1 Page 1 1 Return T o T able Of Contents The supplied cord with plugs is for use with CC or CC/CV welding power sources having the proper , matching 14-pin receptacle. Do not use cordset on machines without the 14-pin receptacle. NOTE 159 645-A / Ref. S-0004-A / S-0283-A Y T ur n Off HF Unit and welding power source, and discon- nect input po ...

  • Miller Electric HF-251-2 - page 16

    OM-61 1 Page 12 Return T o T able Of Contents sb7.1 5/94 − Ref. 098 957-D / Ref. S-0004-A / S-0750 / Ref. 141 127-B 1 Operator Control Receptacle RC1 (See Section 3-6) 2 Keyway 3 Plug 4 Threaded Collar T o connect to receptacle, align keyway , insert plug, and tighten threaded collar . 3 4 OR AJ B K I C L NH D M G E F 12 The 14-socket Operator Co ...

  • Miller Electric HF-251-2 - page 17

    OM-61 1 Page 13 Return T o T able Of Contents Y T urn Off HF Unit and welding power source, and discon- nect input power before making connections. Stop engine on welding genera- tors. Y Not connecting work cables to HF Unit will damage power source. Always connect work cables to W ork Input/ Output terminal. 1 Electrode In T erminal Open left side ...

  • Miller Electric HF-251-2 - page 18

    OM-61 1 Page 14 Return T o T able Of Contents Ref. 159 606-B / Ref. 149 354-A Y Read and follow entire Sec- tion 8 about HF equipment be- fore i n s t a l l i n g u n i t . Y Direct Current (DC) will dam- age HF Unit. Connect unit only to Alternating Current (AC) supply . Do not cut grounding terminal off plug. 1 Grounded Receptacle See Section 3-1 ...

  • Miller Electric HF-251-2 - page 19

    OM-61 1 Page 15 Return T o T able Of Contents SECTION 4 − OPERA TION Ref. 098 956-D 1 Power Switch 2 Pilot Light 3 High Frequency Selector Switch 4 High Frequency Switch 5 High Frequency Intensity Control 4 5 12 3 4-1. Controls Ref. 139 573 1 High Frequency Switch Start − provides HF for arc starting only . Of f − provides no HF . Use Off for ...

  • Miller Electric HF-251-2 - page 20

    OM-61 1 Page 16 Return T o T able Of Contents 1 High Frequency Intensity Control Use control to change amount of HF energy used to start and/or maintain the arc. Set as low as practical to prevent interfering with electronic equipment. 1 4-4. High Frequency Intensity Control 1 Power Switch Use switch to turn unit On and Off. 2 Pilot Light 1 2 4-5. ...

  • Miller Electric HF-251-2 - page 21

    OM-61 1 Page 17 Return T o T able Of Contents SECTION 5 − MAINTENANCE & TROUBLESHOOTING Disconnect all power before maintaining. 3 Months OR Blow O u t Or V acuum Inside Clean And T ighten W eld T erminals Replace Unreadable Labels 6 Months 14-Pin Cord Gas Hose T orch Cable Replace Cracked Parts Adjust Spark Gaps 3 Months T ape Or Replace Cra ...

  • Miller Electric HF-251-2 - page 22

    OM-61 1 Page 18 Return T o T able Of Contents Ref. 098 956-G T urn Of f unit and welding power source and disconnect input power . Loosen screw on spark gap access door and open. 1 Tungsten End Of Point Do not clean or dress tungsten. Replace point if tungsten end disappears. 2 Spark Gap Normal spark gap is 0.008 in (0.203 mm). If spark gaps are ok ...

  • Miller Electric HF-251-2 - page 23

    OM-61 1 Page 19 Return T o T able Of Contents 5-3. T roubleshooting T rouble Remedy Unit completely inoperative; Pilot light Of f. Secure input power cord plug in receptacle (see Section 3-8 ). Place Power switch in the On position (see Section 4-5). Lack of high-frequency; difficulty in es- tablishing an arc. Place High Frequency Selector Switch i ...

  • Miller Electric HF-251-2 - page 24

    OM-61 1 Page 20 Return T o T able Of Contents SECTION 6 − ELECTRICAL DIAGRAMS 130 555-D Figure 6-1. Circuit Diagram For 1 15 V olts Model ...

  • Miller Electric HF-251-2 - page 25

    OM-61 1 Page 21 Return T o T able Of Contents 140 903-E Figure 6-2. Circuit Diagram For 230 V olts Model ...

  • Miller Electric HF-251-2 - page 26

    OM-61 1 Page 22 Return T o T able Of Contents SECTION 7 − HIGH FREQUENCY 7-1. Welding Processes Requiring High Frequency high_freq 12/96 − S-0693 1 High-Frequency V oltage TIG − helps arc jump air gap between torch and workpiece and/ or stabilize the arc. 1 TIG Work 7-2. Incorrect Installation 50 ft (15 m) S-0694 Sources of Direct High-Freque ...

  • Miller Electric HF-251-2 - page 27

    OM-61 1 Page 23 Return T o T able Of Contents 7-3. Correct Installation 1 High-Frequency Source (welding power source with built-in HF or separate HF unit) Ground metal machine case, work output terminal, line disconnect device, input supply , and worktable. 2 Center Point of Welding Zone Midpoint between high-frequency source and welding torch. 3 ...

  • Miller Electric HF-251-2 - page 28

    OM-61 1 Page 24 Return T o T able Of Contents SECTION 8 − SELECTING AND PREP ARING TUNGSTEN ELECTRODE FOR DC OR AC WELDING ac/dc_gtaw 2/2004 Y Whenever possible and practical, use DC weld output instead of AC weld output. 8-1. Selecting T ungsten Electrode ( Wear Clean gloves T o Prevent Contamination Of T ungsten ) Amperage Range - Gas T ype ♦ ...

  • Miller Electric HF-251-2 - page 29

    OM-61 1 Page 25 Return T o T able Of Contents 8-2. Preparing T ungsten Electrode For W elding Y Grinding the tungsten electrode produces dust and flying sparks which can cause injury and start fires. Use local exhaust (forced ventilation) at the grinder or wear an approved respirator . Read MSDS for safety infor- mation. Consider using tungsten con ...

  • Miller Electric HF-251-2 - page 30

    OM-61 1 Page 26 Return T o T able Of Contents 9 -2. T orch Movement During Welding 162 002-B T ungsten Without Filler Rod T ungsten With Filler Rod Form pool T ilt torch Move torch to front of pool. Repeat process. 75 ° 75 ° W elding direction Form pool Tilt torch Add filler metal Move torch to front of pool. Repeat process. Remove rod W elding d ...

  • Miller Electric HF-251-2 - page 31

    OM-61 1 Page 27 Return T o T able Of Contents Notes ...

  • Miller Electric HF-251-2 - page 32

    OM-61 1 Page 28 Return T o T able Of Contents SECTION 10 − P ARTS LIST Figure 10-1. Complete Assembly (Part 1 of 2) (115V Model) 098 955-L Part 1 of 2 . Hardware is common and not available unless listed. 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22 23 18 24 25 26 27 28 29 30 31 32 12 33 34 35 14 36 ...

  • Miller Electric HF-251-2 - page 33

    OM-61 1 Page 29 Return T o T able Of Contents 1 15V Description Part No. Dia. Mkgs. Item No. Figure 10-1. Complete Assembly (Part 1 of 2) Model Quantity 230V 2 206 108 SADDLE CLAMP ASSY 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 +129 366 WRAPPER 1 1 . . . . . . . . . . . . ...

  • Miller Electric HF-251-2 - page 34

    OM-61 1 Page 30 Return T o T able Of Contents 098 955-L Part 2 of 2 . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 7 9 10 16 17 18 19 20 25 21 22 24 25 26 27 23 15 13 14 12 Figure 10-2. Complete Assembly (Part 2 of 2) (115V Model) ...

  • Miller Electric HF-251-2 - page 35

    OM-61 1 Page 31 Return T o T able Of Contents 1 15V Description Part No. Dia. Mkgs. Item No. Figure 10-2. Complete Assembly (Part 2 of 2) Model Quantity 230V 1 SR3 035 704 RECTIFIER, integ 40A 800V 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C14 031 630 CAP ACITOR, elctlt 22uf 50VDC 1 . . . . . . . . . ...

  • Miller Electric HF-251-2 - page 36

    ...

  • Miller Electric HF-251-2 - page 37

    ...

  • Miller Electric HF-251-2 - page 38

    ...

  • Miller Electric HF-251-2 - page 39

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 8/03 Y ou r distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric HF-251-2 - page 40

    PRINTED IN USA  2004 Miller Electric Mfg. Co. 1/04 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 W es t Spenc er S treet Applet on, W I 5 4914 USA International He adquarte rs− USA USA Phone: 920-735-4505 Auto-A t t ended USA & C anada F AX: 920-735-4134 Int ernational F A X: 920-735-4125 European Headqua rt ers − U ...

メーカー Miller Electric カテゴリー Welding System

Miller Electric HF-251-2のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HF-251-2の取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric HF-251-2の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric HF-251-2の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric HF-251-2の取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric HF-251-2のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric HF-251-2の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Miller Electric HF-251-2デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric HF-251-2を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric HF-251-2ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric HF-251-2の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric HF-251-2の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric HF-251-2に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric HF-251-2デバイスの基本機能を使うにあたってのヒント。 Miller Electric HF-251-2のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric HF-251-2に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric HF-251-2のメーカー/サービスへの連絡先に関する情報。

Miller Electric HF-251-2についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric HF-251-2の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric HF-251-2で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)