Trane 4YCY4060Aの取扱説明書

29ページ 2.93 mb
ダウンロード

ページに移動 of 29

Summary
  • Trane 4YCY4060A - page 1

    © 2008 Trane Pub. No. 22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A 22-1797-03 ...

  • Trane 4YCY4060A - page 2

    2 It's Hard to Stop a Trane. Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high ...

  • Trane 4YCY4060A - page 3

    3 Contents Optional Equipment Listing 4 General Data 5 Performance Data Cooling 9 Indoor Fan 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29 ...

  • Trane 4YCY4060A - page 4

    4 Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ✓ ✓ ✓ ✓ ✓ ] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BA Y ACCDOR1A[ ] Hinged Filter Access Door (4YCY4042-060) 8 ............................................... ...

  • Trane 4YCY4060A - page 5

    5 MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.—V/PH/HZ Min ...

  • Trane 4YCY4060A - page 6

    6 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.? ...

  • Trane 4YCY4060A - page 7

    7 General Data 1 1 1 1 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 2 2 2 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% ...

  • Trane 4YCY4060A - page 8

    8 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp. Rise — Min/Max ( ° F) Orifice Qty / Drill Size (Natural Gas) l POWER CONN.? ...

  • Trane 4YCY4060A - page 9

    9 Performance Data Cooling 4YCY4036A1/3 A T 1200 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CAP 72 75 78 80 KW 85 59 34.5 28.8 32.4 34.5 34.5 2.7 63 36.0 23.4 27.0 30.5 32.9 2.7 67 38.8 18.5 22.0 25.6 27.9 2.8 71 41.9 13.5 17.1 20.6 23.0 2.8 95 59 32.0 27.6 31.2 32.0 32.0 ...

  • Trane 4YCY4060A - page 10

    10 Performance Data Cooling 4YCY4048A1/3 A T 1600 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CA P 72 75 78 80 KW 85 59 45.3 38.2 42.9 45.3 45.3 3.6 63 47.2 31.0 35.7 40.5 43.7 3.6 67 50.9 24.4 29.1 33.9 37.1 3.7 71 55.0 17.7 22.5 27.3 30.4 3.7 95 59 42.7 37.0 41.7 42.7 42 ...

  • Trane 4YCY4060A - page 11

    11 Indoor Blower Performance Indoor Fan Performance 4YCY4024A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 52 66 89 115 140 164 186 206 229 259 300 CFM 706 716 727 733 731 719 700 679 662 659 682 Watts - 94 120 148 177 207 233 254 267 290 320 CFM - 793 805 813 813 806 793 780 778 799 800 Watts - - 125 153 182 211 24 ...

  • Trane 4YCY4060A - page 12

    12 Indoor Blower Performance Indoor Fan Performance 4YCY4042A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 162 173 197 226 256 285 313 343 383 440 525 CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts 179 230 265 296 329 366 403 431 450 485 555 CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 114 ...

  • Trane 4YCY4060A - page 13

    13 Indoor Fan Performance 4YCY4060A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 200 220 250 285 320 354 386 417 449 487 538 CFM 1407 1394 1396 1403 1408 1408 1402 1391 1380 1377 1392 Watts 268 316 354 386 417 448 483 520 559 597 630 CFM 1584 1608 1616 1615 1608 1600 1593 1586 1579 1568 1550 Watts 378 430 478 522 56 ...

  • Trane 4YCY4060A - page 14

    14 Heating Airflow, horizontal or downflow from .2 to .6” wg. Selection Low Stage High Stage 7-OFF 8-OFF A 600 850 7-ON 8-OFF B 625 900 7-OFF 8-ON C 650 925 7-ON 8-ON D 700 975 4YCY4024A1064 Switch Settings Nominal Airflow Selection Low Stage High Stage 7-OFF 8-OFF A 725 1000 7-ON 8-OFF B 775 1075 7-OFF 8-ON C 850 1150 7-ON 8-ON D 925 1250 4YCY40 ...

  • Trane 4YCY4060A - page 15

    15 Typical Field Wiring C 757192i2 B G Y W1 W2 R COMMON FA N COMPRESSOR HEA T FIRST ST AGE HEA T SECOND ST AGE 24V UNIT CONTROL BO X GROUND WIRE 3 PH POWER UNIT NO TE 1 1 PH POWER B G Y W1 W2 R COMMON FA N COMPRESSOR HEA T FIRST ST AGE HEA T SECOND ST AGE 24V B G Y W1 W2 R (GR) (WH) (WH) (GR) (WH) (WH) (GR) (WH) (WH) ...

  • Trane 4YCY4060A - page 16

    16 Typical Wiring ...

  • Trane 4YCY4060A - page 17

    17 From Dwg. 21D757165 P02 Typical Wiring ...

  • Trane 4YCY4060A - page 18

    18 Optional Equipment BA YCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 46 3/8 17 7/8 3 3 5/8 19 1/2 2 3/16 19 1/2 14 1 1/2 38 7/8 15 35 7/8 43 3/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build ...

  • Trane 4YCY4060A - page 19

    19 Optional Equipment BA YCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 56 1/8 15 7/8 3 10 7/8 19 1/2 4 3/4 19 1/2 14 41 7/8 20 1 1/2 38 7/8 53 1/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build ...

  • Trane 4YCY4060A - page 20

    20 Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is no t responsible for the unauthorized use of these drawings and expressly d ...

  • Trane 4YCY4060A - page 21

    21 BA YECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) BA YECON200,201A Horizontal Economizer and Rain Hood Return Duct Roofcurb Relief damper Mist eliminator Economizer rain hood HV AC Unit Outside air dampers Return air dampers Required filter kit, order separately A Optional Equipment The drawings ...

  • Trane 4YCY4060A - page 22

    22 A B C D FULL Y OPEN 2/3 1/3 FULL Y CLOSED BA YDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) BA YOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. T ...

  • Trane 4YCY4060A - page 23

    23 Dimensional Data 4YCY4024A through 4YCY4036A (1 of 3) ...

  • Trane 4YCY4060A - page 24

    24 Dimensional Data 4YCY4024A through 4YCY4036A (2 of 3) ...

  • Trane 4YCY4060A - page 25

    25 4YCY4024A through 4YCY4036A (3 of 3) Dimensional Data ...

  • Trane 4YCY4060A - page 26

    26 Dimensional Data 4YCY4042A through 4YCY4060A (1 of 3) ...

  • Trane 4YCY4060A - page 27

    27 Dimensional Data 4YCY4042A through 4YCY4060A (2 of 3) ...

  • Trane 4YCY4060A - page 28

    28 4YCY4042A through 4YCY4060A (3 of 3) Dimensional Data ...

  • Trane 4YCY4060A - page 29

    29 Mechanical Specifications General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 1 15°F. Cooling capacities shall be rated in accordance with A.R.I. standards. The 4YCY4 heating/cooling unit design is UL listed, s ...

メーカー Trane カテゴリー Heat Pump

Trane 4YCY4060Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 4YCY4060Aの取扱説明書
- Traneの製品カード
- パンフレット
- またはTrane 4YCY4060Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Trane 4YCY4060Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Trane 4YCY4060Aの取り付け説明書、サービスマニュアル、簡易説明書、またはTrane 4YCY4060Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Trane 4YCY4060Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Trane 4YCY4060Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTrane 4YCY4060Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのTrane 4YCY4060Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Traneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Trane 4YCY4060Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTrane 4YCY4060Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Trane 4YCY4060Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Trane 4YCY4060Aデバイスの基本機能を使うにあたってのヒント。 Trane 4YCY4060Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Trane 4YCY4060Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTrane 4YCY4060Aのメーカー/サービスへの連絡先に関する情報。

Trane 4YCY4060Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTrane 4YCY4060Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTrane 4YCY4060Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)