Omega Engineering PHTX-11の取扱説明書

14ページ 0.47 mb
ダウンロード

ページに移動 of 14

Summary
  • Omega Engineering PHTX-11 - page 1

    AnO.VfEG.4 Group Company OjyjEGA ENGINEERING, INC. Operator ’ s Manual ...

  • Omega Engineering PHTX-11 - page 2

    M446/026 1 0 Copyright 1986 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing in this manual may be reproduced in any manner, either wholly or in part for any purpose whatsoever without written permission from OMEGA ENGINEERING, INC. Printed in U.S.A. OMEGA3 is a registered trademark of OMEGA ENGINEERING, INC. THERE ARE N ...

  • Omega Engineering PHTX-11 - page 3

    4/s 5/6 PART V SERVICE 1. 2. 3. 4. Block diagram 7 Table I 8 Transmitter dimensions input/output connections and Adjustment pot location Table II 9 10 1 2 2 2 3 4 - CALIBRATION 1. Calibration interval 5 2. Equipment required 5 3. Calibration procedure & TECHNICAL INFORMATION 1. Controls 2. Operation PART IV - OPERATION INSTRUCTION - INSTALLATIO ...

  • Omega Engineering PHTX-11 - page 4

    -l- @ 60 Hz Manual or auto to 95% 600 VDC or peak -120dB +60°C 0 .Ol%/Volt -10 to 3% digit LC D pH k.01 pH ht.01 02%/OC (Display and current out) f. pH *.Ol iim+DC>O~~~ONAL 0 to 3400 ohms Ez ii 2onlA 12 to 80 VDC 1013 ohm 4 to MODEL PHTX-11 SPECIFICATIONS Spans: Input Impedance: Output Current: Power Supply: Load Resistor: Linearity: Temperatur ...

  • Omega Engineering PHTX-11 - page 5

    -2- "U" bolts should bolt to the heavy PVC mounting feet. "U" bolts and nuts. The - attachment to a round pipe requires #lO screws and nuts. 2.3 Pipe Mounting - mounting to a flat surface requires the heavy PVC mounting feet be attached to the box. The surface should be drilled and the feet mounted with 3/4"). Cut the threa ...

  • Omega Engineering PHTX-11 - page 6

    -3- ppm/OC. f ppm/'C or wire wound *50 25'C compensation. The re- sistor used should be metal film 8.66K resistor is normally supplied with the transmitter, this value is correct for Manual temperature compensation requires only a resistor at the terminal strip connection marked with a resistor symbol. Refer to Table I for the value vs. t ...

  • Omega Engineering PHTX-11 - page 7

    -4- iO.0 buffer solution. to the user. pH or a adjustment.when the probe is in a The choice of a 4.0 or 10.0 is up 4.0 pH buffer solution "pH CAL" with the for a reading of 7.0 and the "Slope" probe in a 7.0 pH value of the buffer solution. 2.2 Probe standardization is accomplished by adjusting II-31 of this manual and placing t ...

  • Omega Engineering PHTX-11 - page 8

    -5- pH units. 112 in place. The output is adjustable for a span of 2 to 6 fl and #2 is with jumpers pH point of the range. The adjustments are sensitive and interactive, do not attempt large changes, work both ad- justments in turn with small changes. RANGE mA point at the highest 20 pH point of the range, and the "Span" sets the mA point ...

  • Omega Engineering PHTX-11 - page 9

    -6- pH levels. mA at the desired mA and the "Span" for 20 PII simulator at the input, a resistor at the temperature compensation terminals. (Refer to Table I for the correct resistor and millivolt values). Adjust the "Zero" for 4 h ZERO adjustments interact and require going back and forth between them. Connect a millivolt sourc ...

  • Omega Engineering PHTX-11 - page 10

    - --- _ - _ ----!-! -7 ‘ i _ iI __ l I < ...

  • Omega Engineering PHTX-11 - page 11

    -a- . 1.58K 1.98K 3.08K 4.74K 5.94K 8.66K 20.27K -518.2 Temp. Comp. Res. -4-4-8.8 -476. 6 -504. 4 -148.1 10 -162. 6 -177. 5 -186. 4 -192. 4 -204. 3 -216. 2 -222. 1 11 -216. 8 -236. 6 -248. 5 -256. 5 -272. 4 -288. 2 -296. 1 12 -270. 1 -295. 8 -310. 7 -320. 6 -340. 5 -360.3 , -370. 2 13 -325. 1 -354. 9 -372. 8 -384. 7 -408. 5 -432. 3 -444. 2 14 -379. ...

  • Omega Engineering PHTX-11 - page 12

    1 v- - 9 b ...

  • Omega Engineering PHTX-11 - page 13

    -l O - .t 7 ’ D I A . HOLE EL CUT-OUT TABLE II PAN ...

  • Omega Engineering PHTX-11 - page 14

    06907-0047 (203) 359-1660 Telex: 996404 Cable: OMEGA FAX: (203) 359-7700 Cornpuny One Omega Drive, Box 4047 Stamford, Connecticut AnO.MEGrl Group Benchtopllaboratory Meters Cl Controllers Cl Calibrators/Simulators ?? Transmitters PM •! Electrodes Cl Turbine/Paddlewheel Systems Cl Vortex Meters and Flow Computers FLOW C l Rotameters Cl Flowmeter S ...

メーカー Omega Engineering カテゴリー Satellite Radio

Omega Engineering PHTX-11のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PHTX-11の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering PHTX-11の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering PHTX-11の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering PHTX-11の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering PHTX-11のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering PHTX-11の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering PHTX-11デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering PHTX-11を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering PHTX-11ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering PHTX-11の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering PHTX-11の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering PHTX-11に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering PHTX-11デバイスの基本機能を使うにあたってのヒント。 Omega Engineering PHTX-11のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering PHTX-11に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering PHTX-11のメーカー/サービスへの連絡先に関する情報。

Omega Engineering PHTX-11についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering PHTX-11の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering PHTX-11で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)