MRV Communications EM316T1の取扱説明書

23ページ 0.52 mb
ダウンロード

ページに移動 of 23

Summary
  • MRV Communications EM316T1 - page 1

    EM316 T 1 EM316 E 1 Fiber Driver Modem User’s Guide ...

  • MRV Communications EM316T1 - page 2

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 2 Registration Card Your name: Mr./Ms____________ _______________________________ Organization: _________________ _______Dept. __________________ Your title at organization:__ __________________ __________________ Telephone: _____________ ______________ Fax:__________________ Organization&a ...

  • MRV Communications EM316T1 - page 3

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 3 EM316E1 EM316T1 Fiber Driver Modem User’s Guide ...

  • MRV Communications EM316T1 - page 4

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 4 TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 ORDERING INFORMATION ...

  • MRV Communications EM316T1 - page 5

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 5 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installa tion and operation of the EM316E1/T1 Fiber Modem. Product description describes the product, it s functions, features, protocol supported, minimum req ...

  • MRV Communications EM316T1 - page 6

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 6 Features • Modules can be Inserted / Removed without powering off the chassis • Extensive Network Management Support when used with EM316NM • Provide Fiber Link for T1(ANSI T 1.403) or E1 (G.703) Applications • Built-in Elastic Buffer to Remove Jitter • LED Indicators to help Tr ...

  • MRV Communications EM316T1 - page 7

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 7 Connectivity Connectors Used Fiber: ST, or SC-APC (for single fiber) UTP: RJ48-MDI Coax: BNC (2 connectors: 1 for TX, 1 for RX) Cable Requirement Fiber: ST-ST fiber cable, or SC-APC fiber cable (for single fiber) UTP: Category 5 Coax: RG58/U Port Description Input: E1 (BNC) or T1 (UTP-RJ4 ...

  • MRV Communications EM316T1 - page 8

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 8 Display Information (LED Definition) • PWR/NMS: illuminates when unit is powered (green colo r), flashes (green color) when remote or local loop back is enabled by management. The remote loop back feature provid es a quick check of the basic functionality of both modem s and both fiber ...

  • MRV Communications EM316T1 - page 9

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 9 Typical Applications EM316E1/T1 (Fiber Modem) ...

  • MRV Communications EM316T1 - page 10

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 10 Configuration Jumper Settings: (Factory Default) DO NOT CHANGE THE JUMPER SETTINGS BELOW JUMPER SETTINGS RESULTS JP2 OPEN Factory Use Only JP9 OPEN Factory Use Only W1 OPEN Factory Use Only Note: * Jum per settings with asterisk (*) are factory default ...

  • MRV Communications EM316T1 - page 11

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 11 EM316E1 Jumper Settings for E1 120 Ω Application : 1) Install jumpers between JP3 pins 1 and 2, 2) No jumpers on JP4 and JP5 open, (all pi ns are open) 3) Set all switches on S1 to ON. (BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing mode 2 4 1 3 JP3 ...

  • MRV Communications EM316T1 - page 12

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 12 EM316E1 Jumper Settings for E1 75 Ω Application : 1) Install jumpers between JP3 pins 3 and 4, 2) Install jumpers between JP4 pi ns 1 and 2, JP5 pins 1 and 2 3) Set all switches on S1 to ON. (BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing mode 2 4 1 ...

  • MRV Communications EM316T1 - page 13

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 13 EM316T1 Jumper Settings for T1 100 Ω Application : 1.) Install jumpers between JP3 pins 1 and 2, 2.) No jumpers on JP4 and JP5 open, (all pi ns are open, no headers, not used) 3) Set RECEIVED CODE and TRANSMIT CODE on S1 to ON. (Choose B8ZS as encoder & decoder testing mode) 4) Set ...

  • MRV Communications EM316T1 - page 14

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 14 Theory of Operation Data encoding used on the EM316E1/T1 Fiber Modem consists of converting the incoming AMI B8ZS or HDB3 to a format suitable for fiber optic communication. A proprietary coding scheme is used which combines the input clock and data into a composite signal that is then tr ...

  • MRV Communications EM316T1 - page 15

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 15 2 HARDWARE INSTALLATION PREP ARA TION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards). Groundi ng prevents static charge buildup and electrostatic potential differenc es. T ...

  • MRV Communications EM316T1 - page 16

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 16 f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissip ates the static charge of personnel approaching the workbench. Special conduc tive tile or floor treatment can be used when mats are not practical or cause a safety hazar ...

  • MRV Communications EM316T1 - page 17

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 17 UNIT INSTALLATION STEP 1 Remove required amount of bla nk panels from the NC316BU-xx. NOTE : Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels. STEP 2 Align the edges of the EM316 module to the rail i ...

  • MRV Communications EM316T1 - page 18

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 18 STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid damaging any components on the m odule, handle it by the edges, using your thumb to push it securely inside the ch assis. Do not use excessive force, but make sure the module is fully inserted in the chassis. W hen the modul ...

  • MRV Communications EM316T1 - page 19

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 19 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration. However, if after following the troubl eshooting steps below (in order), you find that the unit is still not functio ...

  • MRV Communications EM316T1 - page 20

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 20 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0 ° C - +50 ° C (32 ° F – 122 ° F) Storage temp -10 ° C - +60 ° C (14 ° F – 140 ° F) Relative Humidity 85% maximum non-condensing Emissions Compliance FCC Part 15, Subpart B, 1999 ...

  • MRV Communications EM316T1 - page 21

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 21 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.com Fax: (978) ...

  • MRV Communications EM316T1 - page 22

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 22 5 GLOSSARY Complete definition of networking term s (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.fiberdriver.com for the latest updates on our products. Fiber Driver Division ...

  • MRV Communications EM316T1 - page 23

    Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 23 Place Stamp Here ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- 8928 Fullbright Avenue Chatsworth, California 91311 U . S . A . ...

メーカー MRV Communications カテゴリー Network Card

MRV Communications EM316T1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EM316T1の取扱説明書
- MRV Communicationsの製品カード
- パンフレット
- またはMRV Communications EM316T1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、MRV Communications EM316T1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、MRV Communications EM316T1の取り付け説明書、サービスマニュアル、簡易説明書、またはMRV Communications EM316T1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、MRV Communications EM316T1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

MRV Communications EM316T1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMRV Communications EM316T1を使用するのを助ける技術的文書のことです。説明書は通常、全てのMRV Communications EM316T1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

MRV Communicationsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. MRV Communications EM316T1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMRV Communications EM316T1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。MRV Communications EM316T1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. MRV Communications EM316T1デバイスの基本機能を使うにあたってのヒント。 MRV Communications EM316T1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。MRV Communications EM316T1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMRV Communications EM316T1のメーカー/サービスへの連絡先に関する情報。

MRV Communications EM316T1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMRV Communications EM316T1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMRV Communications EM316T1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。