Amcor PVMB 9KEH-410の取扱説明書

15ページ 関係なし
ダウンロード

ページに移動 of 15

Summary
  • Amcor PVMB 9KEH-410 - page 1

    R E N O I T I D N O C R I A E L B A T R O P GB Portable air conditioner PVMB 9KEH-410 12KEH-410 15KEH-410 ...

  • Amcor PVMB 9KEH-410 - page 2

    2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer . Before you use your new air conditioner you should carefully read these instructions to maximise th ...

  • Amcor PVMB 9KEH-410 - page 3

    3 • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed • Keep a minimal 0. ...

  • Amcor PVMB 9KEH-410 - page 4

    4 Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S 10 6 5 8 7 9 3 1. Air outlet 2. Control panel 3. C arrying handle 4. Caster wheels 5. Grill housing 6. Upper air inlet 7. Exhaust air outlet 8. Lower air inlet 9. Cable storage 10. Drainage point with water stopper GB 1 2 ...

  • Amcor PVMB 9KEH-410 - page 5

    5 GB INS T A LL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – T o place the loose filters ...

  • Amcor PVMB 9KEH-410 - page 6

    6 GB CON TROL P ANEL A ND DISPLA Y F an speed Clock/timer T emperature Heating Cooling Sleep mode Timer settings Sensor remote control Down Sleep mode Swing Mode Up F an ON/OFF Timer ...

  • Amcor PVMB 9KEH-410 - page 7

    7 ON/OFF Press to switch the unit on, or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour . Press momentarily , the 2 right digits of the 4 digits wil ...

  • Amcor PVMB 9KEH-410 - page 8

    8 Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments in t ...

  • Amcor PVMB 9KEH-410 - page 9

    9 Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing. • Press the -button, the louvres will swing continuously up and down between 30° and 80° a ...

  • Amcor PVMB 9KEH-410 - page 10

    10 The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for pro ...

  • Amcor PVMB 9KEH-410 - page 11

    11 This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. A screen filter , to remove dust particles. b. An active carbon filter , to remove odours. 2. A screen filter in the lower air inlet, to remove dust particles. NOTE! The active carbon filter ...

  • Amcor PVMB 9KEH-410 - page 12

    12 EMP T YING THE INTERNAL W A TER CO NT AINER Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically . T o empty the water container do the following: • Switch off the unit and remove the ...

  • Amcor PVMB 9KEH-410 - page 13

    13 Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on. Is the LCD light fl ashing. Empty the internal water container . T ...

  • Amcor PVMB 9KEH-410 - page 14

    14 Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TEC HN ICAL DA T A Model PVMB 9KEH-410 PVMB 12KEH-410 PVMB 15KEH-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9400 11300 kW 2.2 2.75 3.3 Power consumptio n kW 0.8 1.0 1.5 ...

  • Amcor PVMB 9KEH-410 - page 15

    China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com - GB B M V P 2xxxx 1 3 1 9 ...

メーカー Amcor カテゴリー Air-conditioning

Amcor PVMB 9KEH-410のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PVMB 9KEH-410の取扱説明書
- Amcorの製品カード
- パンフレット
- またはAmcor PVMB 9KEH-410の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Amcor PVMB 9KEH-410の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Amcor PVMB 9KEH-410の取り付け説明書、サービスマニュアル、簡易説明書、またはAmcor PVMB 9KEH-410のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Amcor PVMB 9KEH-410の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Amcor PVMB 9KEH-410デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmcor PVMB 9KEH-410を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmcor PVMB 9KEH-410ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Amcorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Amcor PVMB 9KEH-410の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmcor PVMB 9KEH-410の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Amcor PVMB 9KEH-410に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Amcor PVMB 9KEH-410デバイスの基本機能を使うにあたってのヒント。 Amcor PVMB 9KEH-410のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Amcor PVMB 9KEH-410に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmcor PVMB 9KEH-410のメーカー/サービスへの連絡先に関する情報。

Amcor PVMB 9KEH-410についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmcor PVMB 9KEH-410の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmcor PVMB 9KEH-410で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)