    MODEL CO2120PDN—User’ s Manual 120V Plug-In Carbon Monoxide Alarm W ith Digital Display and Silence Feature M06-1045-000 6/99 120V AC 60 Hz .085A Standby .087A Alarm With Peak CO Level Display! ...

  • BRK electronic CO2120PDN - page 2

    T ABLE OF CONTENTS CHAPTER 1: INTR ODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 How Y our CO Alarm W orks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • BRK electronic CO2120PDN - page 3

    1 CHAPTER 1: Introduction BASIC SAFETY INFORMATION IMPORT ANT! Dangers, W arnings, and Cautions alert you to important operating instructions or to potentially hazar dous situations. Pay special attention to these items. IMPORT ANT! THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide fr om ANY source of combustion. It is ...

  • BRK electronic CO2120PDN - page 4

    2 HOW Y OUR CO ALARM WORKS General Information CAUTION! Leave your CO Alarm plugged in year -round. CO problems can occur any time during the year , and this alarm can only alert you if it is plugged in and r eceiving power . This CO Alarm is intended for use in a standard, unswitched 120V AC wall outlet. It is not intended for use in extension cor ...

  • BRK electronic CO2120PDN - page 5

    3 WHAT THE DIGITAL DISPLAY CAN SHOW Y OU The Digital Display is designed to indicate estimated carbon monoxide levels in a r esidential environment. It is not intended for use as an industrial or commer cial grade meter . The Digital Display shows the amount of carbon monoxide (measur ed in parts per million) the unit is sensing. An average, health ...

  • BRK electronic CO2120PDN - page 6

    4 WHAT THE LIGHTS AND ALARM T ONES MEAN During Power Up (or After Power Outage) Green light ON. Y ellow & red lights OFF . Horn “chirps”. Digital Display: Dash appears by “READY”. During an Alarm Green light ON. Y ellow light OFF . Red light FLASHES. Repeating horn patter n: 4 beeps, pause, 4 beeps, pause. Display: Shows CO levels in pp ...

  • BRK electronic CO2120PDN - page 7

    5 THE PEAK CO FEA TURE This feature lets you check the highest level of CO detected since you clear ed the Peak memory . This feature also helps a CO investigator . Since you should ventilate your home after any alarm — and since CO dissipates in fresh air — CO levels may dr op well below alarm levels by the time investigator arrives. T o check ...

  • BRK electronic CO2120PDN - page 8

    6 CO ALARM SPECIFICATIONS Gas Detection at T ypical T emperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically . UL tested for false alarm r esistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). V alues ...

  • BRK electronic CO2120PDN - page 9

    7 CHAPTER 2: Installation WHERE TO INSTALL CO ALARMS The Consumer Pr oduct Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. For added pr otection, install additional CO Alarms in each separate bedr oom, and on every level of your home. If your bedroom hallway is longer than 40 feet, ...

  • BRK electronic CO2120PDN - page 10

    8 WHERE NOT T O INSTALL Y OUR CO ALARM DO NOT locate this CO Alarm: • In garages, kitchens, furnace r ooms, or in any extr emely dusty , dirty or greasy ar eas. • Closer than 20 feet away fr om a furnace or other fuel burning heat sour ce, or fuel burning appliances like a water heater . • Within 5 feet of any cooking appliance. • In extrem ...

  • BRK electronic CO2120PDN - page 11

    9 HOW TO INSTALL Y OUR CO ALARM W ARNING! This CO Alarm can not operate without continuous electricity . It does not operate during a power failur e. Do not use in an extension cor d, or outlet controlled by a dimmer or switch — unit must have a constant power supply . CAUTION! Leave your CO Alarm plugged in year -round. CO problems can occur any ...

  • BRK electronic CO2120PDN - page 12

    10 CHAPTER 3: If Y our CO Alarm Alarms W ARNING! Actuation of your CO alarm indicates the presence of carbon monoxide (CO) which can KILL YOU. In other wor ds, when your CO Alarm alarms, you must not ignor e it! If the Alarm Signal Sounds: 1. Operate the T est/Silence button. Write down the numbers on the Digital Display and the current time. 2. Ca ...

  • BRK electronic CO2120PDN - page 13

    11 Using the Silence Feature W ARNING! NEVER unplug your CO alarm to silence the horn. Use the silence featur e. Unplugging the CO alarm r emoves your protection! See previous page for details on r esponding to an alarm. The silence featur e is intended to temporarily silence your CO Alarm ’ s alarm horn while you correct the pr oblem — it will ...

  • BRK electronic CO2120PDN - page 14

    12 CHAPTER 4: T esting and Maintenance W EEKLY T ESTING Push and hold the T est/Silence button on the cover until a loud alarm sounds — 4 beeps, a pause, then 4 beeps. The alarm sequence should last for 5-6 seconds. If the Alarm ever fails to test pr operly , replace it immediately . If the CO Alarm is not working pr operly , refer to the “ Lim ...

  • BRK electronic CO2120PDN - page 15

    13 CHAPTER 5: What Y ou Need T o Know About CO What is CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not bur n completely , or are exposed to heat (usually fi re). Electrical appliances typically do not produce CO. These fuels include: W ood, coal, charcoal, oil, natural gas, gasoline, ker osene, and propane. Common ...

  • BRK electronic CO2120PDN - page 16

    14 Potential Sources Of CO In The Home Fuel-burning appliances like: portable heater , gas or wood burning fi replace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insuf fi cient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or fl ue, or cracked heat exchanger , blocked or clogged chimney opening. ...

  • BRK electronic CO2120PDN - page 17

    15 How Can I Protect My Family? A CO Alarm is an excellent means of pr otection. It monitors the air and sounds a loud alarm before Carbon Monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for pr oper maintenance of home appliances. T o help prevent CO problems and r educe the risk of CO poisoning: • C ...

  • BRK electronic CO2120PDN - page 18

    16 CHAPTER 6: Underwriters Laboratories Inc. UL2034 What Levels of CO Cause an Alarm? Underwriters Laboratories Inc. UL2034 de fi nes 3 speci fi c alarm points by which all r esidential CO Alarms must alarm. They ar e measured in parts per million (ppm) of CO over time (in minutes). UL2034 Requir ed Alarm Points: • If the alarm is exposed to 40 ...

  • BRK electronic CO2120PDN - page 19

    17 CHAPTER 7: Troubleshooting Guide Problem... This means... Y ou should... Green light is OFF . Unit will not alarm when you pr ess the T est/Silence button. Unit may not be plugged all the way in, or receiving power . Gently push unit all the way into outlet. Make sure it is not plugged into an outlet controlled by a switch. Unit “ chirps ” a ...

  • BRK electronic CO2120PDN - page 20

    18 CHAPTER 8: General Limitations Of CO Alarms This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met. CO Alarms will not work without power . This CO Alarm requires a continuous supply of A ...

  • BRK electronic CO2120PDN - page 21

    Limited W arranty Coverage: BRK Brands, Inc. warrants its enclosed carbon monoxide alarm to be free fr om defects in materials and workmanship under normal use for a period of fi ve years fr om the date of purchase. During the fi rst year after the date of purchase, BRK Brands, Inc. will r eplace any defective carbon monoxide alarm without char g ...

メーカー BRK electronic カテゴリー Smoke Alarm

BRK electronic CO2120PDNのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CO2120PDNの取扱説明書
- BRK electronicの製品カード
- パンフレット
- またはBRK electronic CO2120PDNの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、BRK electronic CO2120PDNの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、BRK electronic CO2120PDNの取り付け説明書、サービスマニュアル、簡易説明書、またはBRK electronic CO2120PDNのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、BRK electronic CO2120PDNの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

BRK electronic CO2120PDNデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBRK electronic CO2120PDNを使用するのを助ける技術的文書のことです。説明書は通常、全てのBRK electronic CO2120PDNユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

BRK electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. BRK electronic CO2120PDNの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBRK electronic CO2120PDNの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。BRK electronic CO2120PDNに関してこのドキュメントで見つけることができる全てのヒントの目次
3. BRK electronic CO2120PDNデバイスの基本機能を使うにあたってのヒント。 BRK electronic CO2120PDNのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。BRK electronic CO2120PDNに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBRK electronic CO2120PDNのメーカー/サービスへの連絡先に関する情報。

BRK electronic CO2120PDNについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBRK electronic CO2120PDNの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBRK electronic CO2120PDNで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)