Bunn DUAL TM (Serial # DUAL010000 - Up)の取扱説明書

52ページ 3.79 mb
ダウンロード

ページに移動 of 52

Summary
  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 1

    BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com OPERA TING & SER VICE MANU AL C A U T I O N : W A R M E R S A N D S U R F A C E S A R E H O T CAUTION D IS C A R D D E C A N T E R IF : . C R A C K E D . S C R A T C H E D . B O I L E D D R Y . H E A T E ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 2

    Page 2 INTRODUCTION This equipment will brew two half-gallon, gallon, or gallon and a half batches of coffee into awaiting servers at the push of a button. The brewer is also equipped with a hot water faucet for allied beverage use and is designed to interface with a BUNN ® Grinder. The brewer is specifically designed for use with a BUNN ® 1.5 GP ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 3

    Page 3 Requires 2-wire, grounded service rated 200 to 240 volts ac, 30 amp, single phase 50 or 60 Hz. Requires 3-wire, grounded service rated 120/208 or 120/ 240 volts ac, 30 amp, single phase, 60 Hz. 120V A.C. 120V A.C. 120V A.C. 208 or 240V A.C. L2 RED L2 RED WHITE NEUTRAL L1 BLACK L1 BLACK 200 or 240V A.C. USER NOTICES (cont.) ELECTRICAL REQUIRE ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 4

    Page 4 CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Remove the front panel beneath the sprayheads. Models with electronic control assemblies: Place ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 5

    Page 5 27040 032201 Models with electro/mechanical thermostats: Rotate the control thermostat knob fully clockwise to the “ON” position and replace the front panel. 4. Wait approximately twenty minutes for the water in the tank to heat to the proper temperature. 5. Place an empty server beneath either brew station and the ON/OFF switch in the u ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 6

    Page 6 27040 032201 OPERA TING CONTROLS BREW SELECTOR SWITCH (Triple - set timer models only) Placing the switch in the 1 ⁄ 2 Gal, 1 Gal, or 1 1 ⁄ 2 Gal position selects the amount of coffee to be brewed in subsequent brew cycles. Repositioning this switch after a brew cycle has been initiated does not change the brew batch in progress. ON/OFF ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 7

    Page 7 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 8

    Page 8 TROUBLESHOOTING (cont.) Problem Brew cycle will not start (cont.) Automatic refill will not operate Remedy Refer to Service - ON/OFF switch for testing procedures. See page 31 Refer to Service - Start switch for testing procedures. See page 36 Refer to Service - Timer for testing procedures. See page 38 or 41 Refer to Service - Dispense valv ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 9

    Page 9 TROUBLESHOOTING (cont.) Problem Beverage level will not adjust (Selector switch in any position) Water flows into tank continuously . Water flows into tank continuously (ON/OFF switch "ON"). Water from tank is not hot Probable Cause 1. Brew Selector switch 1. Solenoid valve 2A. Level control board and level probe (Electro/mechanica ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 10

    Page 10 TROUBLESHOOTING (cont.) Problem Water from tank is not hot (cont.). Server warmer is not hot. Spitting or unusual steaming from sprayhead or airvents. Inconsistent beverage level in server. Probable Cause 6. Relay (Brewers with Recovery Booster) 1. ON/OFF switch 2. Warmer element 1A. Control thermostat (Electro/me- chanical) 1B. Control ass ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 11

    Page 11 TROUBLESHOOTING (cont.) Problem Inconsistent beverage level in server (cont.). Consistently high or low beverage level in server. Dripping from sprayhead. Water overflows filter. Beverage overflows server. Weak beverage. Probable Cause 3. Dispense valve 1. Timer adjustment 1. Dispense valve 1. Bypass valve 2. Needle Valve 3. Type of paper f ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 12

    Page 12 TROUBLESHOOTING (cont.) Problem Weak beverage (cont.) Brewer is making unusual noises. Probable Cause 3. Sprayhead 4. Funnel loading 5. Water temperature 1. Solenoid (Inlet) 2. Plumbing lines 3. Water supply 4. Tank Heaters 5. Contactor Remedy B.O.M. sprayhead #01082.0002 should be used to properly wet the bed of ground coffee in the funnel ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 13

    Page 13 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service pe ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 14

    Page 14 SERVICE (cont.) BYPASS VALVE Location: The bypass valves are located inside the right front and the center front of the hood. Test Procedures: 1. Disconnect the brewer from the power source and place a server beneath the funnel. 2. Check the water level in the tank to confirm that it is within 1/2" from the top of the tank. 3. Connect ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 15

    Page 15 SERVICE (cont.) BREW SELECTOR SWITCH Location: The brew selector switches are located in the front left and right side of the hood. Test Procedure: 1. Disconnect the brewer from the power supply. 2. Separate the connector on the selector switch harness from the brew timer circuit board. 3. Carefully slide the plastic cover off of the con- n ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 16

    Page 16 SERVICE (cont.) P776 27040 032201 To Left or Right Timer TAN GRY PNK WHI/VIO to Left or Right By-Pass Valve WHI/RED to Left or Right Dispense Valve GRY to Left or Right Selector Switch to GRY Lead on Interface Socket PNK from Left Switch to Grinder Switch (Lower Left) PNK from Right Switch to Grinder Switch (Lower Right) TAN to Left or Righ ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 17

    Page 17 SERVICE (cont.) CONTACTOR ASSEMBLY Location: The contactor assembly is located inside the hood just to the rear of the right dispense valve. Test Procedures: Mechanical Thermostat (Brewers with or without Recovery Booster) 1. Disconnect the brewer from the power source. 2. Disconnect the red wire of the two pole 200V or 240V terminal block ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 18

    Page 18 SERVICE (cont.) CONTACTOR ASSEMBLY (cont.) P778 27040 032201 Test Procedures : Electronic Control (Brewers w/Recovery Booster) 1. Disconnect the brewer from the power source. 2. Disconnect the gray wire from the black wire on the rear of the contactor coil and white /brown wire from the black wire on the front of the contactor coil. 3. With ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 19

    Page 19 b.) 200 to 240 volts ac for two wire 200 or 240 volt models. 4. Disconnect the brewer from the power source. If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the Wiring Diagrams and check brewer wiring harness. 5. Locate the black wires from the control thermo- stat. 6. Gently remove the ca ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 20

    Page 20 P780 SERVICE (cont.) 27040 032201 Removal and Replacement: 1. Remove wires from the control thermostat. 2. Remove the thermostat capillary bulb by firmly pulling up on the capillary tube at the tank lid. This will disengage the grommet from the tank lid. 3. Remove the #8-32 slotted head screw holding the control thermostat to the component ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 21

    Page 21 . M I N U T E S B U N N - O- M A T I C P / N 2 6 2 0 - 1 2 0 V A C . M I N U T E S B U N N - O- M A T I C P / N 2 6 2 0 - 1 2 0 V A C ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 22

    Page 22 SERVICE (cont.) Location: The electronic control assembly (1) is located inside the lower left front on the component bracket of the brewer. Access will also be needed to the tempera- ture sensor (8), liquid level probe (7) located on the tank lid and to the triac assembly (17) located beneath the tank. General: This system controls the liq ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 23

    Page 23 SERVICE (cont.) PROBLEM: LIQUID LEVEL CONTROL SYSTEM DOES NOT REFILL PROBLEM: LIQUID LEVEL CONTROL OVERFLOWS RETRY NO YES YES NO YES REPLACE CONTROL ASSEMBLY (1) DRAIN CUP (4) OVERFLOW ? OVERFLOW ? NO OVERFLOW ? REPLACE SOLENOID VALVE (14) DRAIN CUP (4) DISCONNECT WIRE SOLENOID VALVE (14) FROM RETRY REPLACE PROBE (7) DRAIN CUP (4) DISCONNEC ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 24

    Page 24 YES YES YES YES NO NO NO NO YES NO NO MEASURE VOLTAGE AT TANK HEATER (5) VOLTAGE PRESENT REPLACE TANK HEATER (5) LIMIT THERMOSTAT (6) OK ? REPLACE LIMIT THERMOSTAT (6) REPLACE CONTROL ASSEMBLY (1) MEASURE VOLTAGE AT TANK HEATER (5) VOLTAGE PRESENT REPLACE TRIAC (17) CHECK FOR SPLIT TANK HEATER (5) REINSTALL ORIGINAL CONTROL ASSEMBLY (1) REC ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 25

    Page 25 SERVICE (cont.) ELECTRONIC CONTROLS (cont.) PROBLEM: WATER BOILS YES NO NO NO NO REPLACE CONTROL ASSEMBLY (1) REPLACE TRIAC (17) CHECK FOR SPLIT TANK HEATER (5) DRAIN CUP (4) RETRY LED (13)(15) ON WHILE BOILING DISCONNECT BLUE WIRE FROM CONTROL BOARD PIN #7 RETRY STILL BOILING ? REPLACE CONTROL ASSEMBLY (1) assembly (1). NOTE - each tempera ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 26

    Page 26 SERVICE (cont.) ELECTRONIC CONTROL ASSEMBLY (cont.) O N CAUTION ! F ailu re To Com p ly V o id s W a rra n t y! Ho t W a te r S y s te m s – W a te r T a n k W ill F ill A u to m a tic a lly W h e n U n it Is C o n n e c t e d T o P o w e r! Coffe e Brewers – F ill T h e W a te r T a n k In A c c o rd a n c e W ith T h e In s ta ll a ti ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 27

    Page 27 P787 SERVICE (cont.) ELECTRONIC CONTROL ASSEMBLY (cont.) 11. Install new triac/heat sink assembly on right tank mounting bracket. 12. Route the wires up around the rear of the brewer. 13. Reinstall the bottom cover, four feet, tank mount- ing brackets and triac/heat sink to the bottom of the tank using four #10-32 keps nuts. 14. Secure bott ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 28

    Page 28 ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 29

    Page 29 SERVICE (cont.) LEVEL CONTROL BOARD AND LEVEL PROBE (Electro/ mechanical only) (cont.) 15. Move the probe's flat end to the brewer housing. The indication must be 0. 16. Move the probe's flat end away from the brewer housing. The indication should again be: a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 30

    Page 30 SERVICE (cont.) If voltage is present as described, reconnect the black wire to the limit thermostat from the terminal block, the limit thermostat is operating properly. If voltage is not present as described, refer to the Wiring Diagrams and check brewer wiring harness. Removal and Replacement: 1. Remove all wires from the limit thermostat ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 31

    Page 31 SERVICE (cont.) Location: The ON/OFF switches are located on the front of the hood just to the left and right of the start switches. Test Procedure: 1. Disconnect the brewer from the power source. 2. Viewing the switch from the back remove the white or red wire from the upper right terminal and the black wire from the center terminal. 3. Wi ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 32

    Page 32 Location: The overflow protection switch is located inside the hood on the center of the tank inside the copper overflow cup. To test the overflow protection switch, access will also be needed to the level control board or electronic control assembly and terminal block. Test Procedure: 1. Disconnect the brewer from the power source. 2. Remo ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 33

    Page 33 ! C A U T I O N H O T W A T E R . M IN U T E S B U N N- O-MAT IC P /N 2 62 0- 12 0 V A C . M IN U T E S B U N N - O-MAT IC P /N 26 20 - 1 20 V A C ST ART O N / W ARM E R S EL EC T O R R E AD Y R E A D Y O N / W A RM E R S T ART 1 1 ⁄ 2 g a l 1 g a l 1 ⁄ 2 g a l S EL E C T O R 1 1 ⁄ 2 g a l 1 g a l 1 ⁄ 2 g a l ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 34

    Page 34 RED BLK to BLK Lead on Contactor Coil BLK to BLK Lead on Thermostat WHI/RED to Left Dispense Valve WHI/BRN to Left Dispense Valve WHI/GRN to Right Dispense Valve BLU to BLU Lead from Thermostat BLU to BLU Lead from Liquid Level Board WHI/VIO to Right Dispense Valve RIGHT LEFT GRY to BLK Lead from Contactor Coil WHI/VIO to Right Dispense Val ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 35

    Page 35 SERVICE (cont.) SOLENOID VALVE (Inlet) ! C A U T I O N H O T W A T E R . M INU T E S B UNN - O-MA TIC P/N 26 20- 12 0 V AC . M IN UT E S B U NN - O-MATIC P /N 26 20- 120 V A C S T A RT RE A DY ON / WA RM ER S TA RT S E L E CT O R 1 1 ⁄ 2 g a l 1 g a l 1 ⁄ 2 g a l C A U T I O N : W A R M E R S A N D S UR F A C E S AR E H O T ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 36

    Page 36 START ON / W AR MER SELECTOR READY R EADY ON / W AR ME R START 1 1 ⁄ 2 g a l 1 g a l 1 ⁄ 2 g a l SEL EC TOR 1 1 ⁄ 2 g a l 1 g a l 1 ⁄ 2 g a l P792 START SWITCHES Location: The momentary start switches are located in front of hood just left and right of center. Test Procedure: 1. Disconnect the brewer from the power source and remove ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 37

    Page 37 tank heater(s). NOTE - If the tank heater remains unable to heat, remove and inspect the heater for cracks in the sheath. Electronic Models: 1. Disconnect the brewer from the power source. 2. Disconnect wires from heater(s). 3. Check for continuity across the tank heater termi- nals. If continuity is present as described, the tank heater is ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 38

    Page 38 Location: The timers are located inside the left front of the brewer on the upper part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the wires from the timer terminals TL3, TL4 and TL5 and rotate the dial(s) fully counterclockwise. 3. With a voltmeter, check the voltage across termi ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 39

    Page 39 . MINUTES B UNN-O-MATIC P/N 2620- 120 VAC . MINUTES BUNN-O-M ATIC P/N 2620- 120 VAC WHI/VIO TL1 to Right ON/OFF Switch WHI/VIO TL1 to Right Warmer Element WHI/RED TL1 to Left ON/OFF Switch WHI/RED TL1 to Left Warmer Element ORA TL3 to Left Start Switch WHI/BRN TL4 to Left Dispense Valve YEL TL5 to Left Start Switc WHI TL2 To Terminal Block ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 40

    Page 40 SERVICE (cont.) Timers (Early Models)(cont.) P847 . M I N U T E S B U N N - O - M A T IC P /N 2 6 2 0 - 1 2 0 V A C . M IN U T E S B U N N - O -M A T I C P / N 2 6 2 0 - 1 2 0 V A C WHI/VIO TL1 to Right ON/OFF Switch WHI/VIO TL1 to Right Warmer Element WHI/RED TL1 to Left ON/OFF Switch WHI/RED TL1 to Left Warmer Element ORA TL3 toInterlock ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 41

    Page 41 27040 032201 SERVICE (cont.) TIMERS (Late Models) P2194 Location: The timers are located inside the left front of the brewer on the upper part of the component bracket. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect the brewer fro ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 42

    Page 42 27040 032201 P2037 SERVICE (cont.) TIMERS (Late Models)(cont.) LEFT TIMER RIGHT TIMER YEL WHI/YEL wire to TL5 WHI/BRN WHI/GRN wire to TL4 ORA WHI/ORA wire to TL3 WHI WHI wire to TL2 (120V Two Pole, 120/208V or 120/240V Three Pole Terminal Block) RED RED wire to TL2 (200V or 240V Two Pole Terminal Block) WHI/RED WHI/VOI wire to TL1 1. Modify ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 43

    Page 43 SERVICE (cont.) WARMER ELEMENTS WHI/VIO to Right Timer TL1 WHI to Terminal Block (White Insert on Three Pole Terminal Blocks or Red Insert on Two Pole Terminal Blocks) WHI or Red to Left Warmer Element RIGHT WARMER ELEMENT LEFT WARMER ELEMENT WHI to Terminal Block (White Insert on Three Pole Terminal Blocks or Red Insert on Two Pole Termina ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 44

    Page 44 120/208 VOLTS AC OR 120/240 VOLTS AC 3 WIRE R T S E L E C T O R S W VIO PROBE PIN-20 1 4 3 2 LIQUID LEVEL BOARD BLU BLK K1 WHI LIMIT THERMOSTAT SOL WHI WHI OVERFLOW PROTECTION SW RED RED SW. & THERMOSTAT READY INDICATORS OPTIONAL RECOVERY BOOSTER BLK BLU K2 N.O. K3 N.O. RED SCHEMATIC WIRING DIAGRAM DUAL BREWER (W/TWO-GRINDER INTERFACE) ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 45

    Page 45 R T S E L E C T O R S W VIO PROBE PIN-20 1 4 3 2 LIQUID LEVEL BOARD BLU K1 RED SOL RED RED SW. & THERMOSTAT READY INDICATORS OPTIONAL RECOVERY BOOSTER BLK BLU K2 N.O. K3 N.O. RED SCHEMATIC WIRING DIAGRAM DUAL-A & -B BREWER (W/TWO-GRINDER INTERFACE) GRN/YEL RED-12 K1 N.O. BLU TANK HEATERS (TWO) 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 46

    Page 46 BLK-12 BLU-12 SCHEMATIC WIRING DIAGRAM DUAL BREWER ECA (W/TWO-GRINDER INTERFACE) R T S E L E C T O R S W WHI WHI/ORA WHI/VIO WHI/GRN WHI/YEL WHI WHI/RED WHI/GRN L1 N TANK HEATERS (TWO) BLK 1 RIGHT BREW TIMER 3 2 4 5 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH 3/4 BATCH BATCH COMMON FRACTIONAL BATCHES (CONNECT AS REQUIRED) FULL BATCH (NO CONNECT ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 47

    Page 47 SCHEMATIC WIRING DIAGRAM DUAL-A & -B BREWER ECA (W/TWO-GRINDER INTERFACE) R T S E L E C T O R S W RED WHI/ORA WHI/VIO WHI/GRN WHI/YEL RED WHI/RED WHI/GRN L1 GRN/YEL TANK HEATERS (TWO) BLK 1 RIGHT BREW TIMER 3 2 4 5 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH 3/4 BATCH BATCH COMMON FRACTIONAL BATCHES (CONNECT AS REQUIRED) FULL BATCH (NO CONN ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 48

    Page 48 120/208 VOLTS AC OR 120/240 VOLTS AC 3 WIRE R T S E L E C T O R S W VIO PROBE PIN-20 1 4 3 2 LIQUID LEVEL BOARD BLU BLK K1 WHI LIMIT THERMOSTAT SOL WHI WHI OVERFLOW PROTECTION SW RED RED SW. & THERMOSTAT READY INDICATORS OPTIONAL RECOVERY BOOSTER BLK BLU K2 N.O. K3 N.O. RED SCHEMATIC WIRING DIAGRAM DUAL BREWER (W/ONE-GRINDER INTERFACE) ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 49

    Page 49 BLK-12 BLU-12 SCHEMATIC WIRING DIAGRAM DUAL BREWER ECA (W/ONE-GRINDER INTERFACE) R T S E L E C T O R S W WHI WHI/ORA WHI/VIO WHI/GRN WHI/YEL WHI WHI/RED WHI/GRN L1 N TANK HEATERS (TWO) BLK 1 RIGHT BREW TIMER 3 2 4 5 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH 3/4 BATCH BATCH COMMON FRACTIONAL BATCHES (CONNECT AS REQUIRED) FULL BATCH (NO CONNECT ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 50

    Page 50 R T S E L E C T O R S W VIO PROBE PIN-20 1 4 3 2 LIQUID LEVEL BOARD BLU K1 RED SOL RED RED SW. & THERMOSTAT READY INDICATORS OPTIONAL RECOVERY BOOSTER BLK BLU K2 N.O. K3 N.O. RED SCHEMATIC WIRING DIAGRAM DUAL-A & -B BREWER (W/ONE-GRINDER INTERFACE) GRN/YEL RED-12 K1 N.O. BLU TANK HEATERS (TWO) 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 51

    Page 51 SCHEMATIC WIRING DIAGRAM DUAL-A & -B BREWER ECA (W/ONE-GRINDER INTERFACE) R T S E L E C T O R S W RED WHI/ORA WHI/VIO WHI/GRN WHI/YEL RED WHI/RED WHI/GRN L1 GRN/YEL TANK HEATERS (TWO) BLK 1 RIGHT BREW TIMER 3 2 4 5 1/4 BATCH 1/3 BATCH 1/2 BATCH 2/3 BATCH 3/4 BATCH BATCH COMMON FRACTIONAL BATCHES (CONNECT AS REQUIRED) FULL BATCH (NO CONN ...

  • Bunn DUAL TM (Serial # DUAL010000 - Up) - page 52

    Page 52 WHI/GRN WHI/GRN WHI/RED WHI/RED RT START SW BLK BLK LT START SW BLK GRN BLK YEL BLK RED BLK PNK TAN GRY WHI WHI RED RED GRY PNK PNK RED WHI PNK RED ORA YEL VIO BLU WHI/RED WHI/RED WHI WHI WHI BLK TAN BLU WHI/BLU 10864.0000H 9/00 © 1995 BUNN-O-MATIC CORPORATION WHI REFILL RED BLK RED WHI PNK RED GRY TAN PNK PNK BLU BLU WHI/VIO WHI/VIO RT ON ...

メーカー Bunn カテゴリー Coffeemaker

Bunn DUAL TM (Serial # DUAL010000 - Up)のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DUAL TM (Serial # DUAL010000 - Up)の取扱説明書
- Bunnの製品カード
- パンフレット
- またはBunn DUAL TM (Serial # DUAL010000 - Up)の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bunn DUAL TM (Serial # DUAL010000 - Up)の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bunn DUAL TM (Serial # DUAL010000 - Up)の取り付け説明書、サービスマニュアル、簡易説明書、またはBunn DUAL TM (Serial # DUAL010000 - Up)のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bunn DUAL TM (Serial # DUAL010000 - Up)の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bunn DUAL TM (Serial # DUAL010000 - Up)デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBunn DUAL TM (Serial # DUAL010000 - Up)を使用するのを助ける技術的文書のことです。説明書は通常、全てのBunn DUAL TM (Serial # DUAL010000 - Up)ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bunnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bunn DUAL TM (Serial # DUAL010000 - Up)の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBunn DUAL TM (Serial # DUAL010000 - Up)の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bunn DUAL TM (Serial # DUAL010000 - Up)に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bunn DUAL TM (Serial # DUAL010000 - Up)デバイスの基本機能を使うにあたってのヒント。 Bunn DUAL TM (Serial # DUAL010000 - Up)のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bunn DUAL TM (Serial # DUAL010000 - Up)に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBunn DUAL TM (Serial # DUAL010000 - Up)のメーカー/サービスへの連絡先に関する情報。

Bunn DUAL TM (Serial # DUAL010000 - Up)についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBunn DUAL TM (Serial # DUAL010000 - Up)の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBunn DUAL TM (Serial # DUAL010000 - Up)で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)