  • National Instruments NI 6509 - page 1

    USER GUIDE AND SPECIFICATIONS NI 6509 The NI 6509 is a 96-bit, high-drive digital input/outp ut (I/O) device for PCI, PXI, and CompactPCI ch assis . The NI 6509 features 96 TTL/CMOS-compatible digita l I/O lines, 24 mA high-driv e output, a watchdog timer , digital f iltering, and programmable power-up states. Contents Configuration ............... ...

  • National Instruments NI 6509 - page 2

    NI 6509 User Guide an d Specifications 2 ni.com Configuration The NI 6509 device is completely software config urable, so it is not necessary to set jumper s for I/O config uration. The PCI-6509 device is fu lly compliant with the PCI Local Bus Specification, Revision 2.2 , and th e PXI-6509 device is fully compliant with the PXI Hardware Specifica ...

  • National Instruments NI 6509 - page 3

    © National Instruments Corporation 3 NI 6509 User Gu id e and Specifications Programming Devices in Software National Instruments measurement de vices are packaged with NI-DAQ driver software, an extens ive library o f functions and VIs yo u can call from your application software, such as LabVIEW or LabWin dows ™ /CVI ™ , to program all the f ...

  • National Instruments NI 6509 - page 4

    NI 6509 User Guide an d Specifications 4 ni.com Functional Over view Figure 1 shows the key functional components of the NI 650 9 device. Figure 1. NI 6509 Block Diagram Safety Information The following section contains important safety info rmation that you must follow when installi ng and using National Inst ruments DIO devices. Do not operate th ...

  • National Instruments NI 6509 - page 5

    © National Instruments Corporation 5 NI 6509 User Gu id e and Specifications If you need to clean the DIO device, use a soft, nonmetallic brush. M ake sure that the DIO device is complete ly dry and free fr om contaminants before returning it to service. Operate the DIO device only at or belo w Pollution Degree 2. Pollution is foreign matter in a ...

  • National Instruments NI 6509 - page 6

    NI 6509 User Guide an d Specifications 6 ni.com • Measurement Category II is for m easurements performed on circuits directly connected to the electrical dist ribution system. This cat egory refers to local-le vel elect rical distribution, such as that provided b y a standard wall outlet (for example, 115 V for U.S. or 230 V for Europe). Examples ...

  • National Instruments NI 6509 - page 7

    © National Instruments Corporation 7 NI 6509 User Gu id e and Specifications Features The NI 6509 features digital filtering , programmable power-up states, change detection, and a watchdog t imer. Digital Filtering Use the digital filter option available on t he NI 6509 input lin es to eliminate glitches on input data. W hen used with change dete ...

  • National Instruments NI 6509 - page 8

    NI 6509 User Guide an d Specifications 8 ni.com Digital Filtering Example Figure 2 shows a filter configuration with an 800 ns filter interval (400 ns filter clock). Figure 2. Digital Filtering Example In periods A and B, the filter blocks th e glitches because th e external signal does not remain steadil y high from one rising edge of th e filter ...

  • National Instruments NI 6509 - page 9

    © National Instruments Corporation 9 NI 6509 User Gu id e and Specifications Change Detection You can program the NI 6509 to send an interrupt when a change occurs on any input line. The NI 6509 can monitor changes on selected input lines or on all input lines. It can monitor for rising edges (0 to 1), falling edges (1 to 0), or both. When an inpu ...

  • National Instruments NI 6509 - page 10

    NI 6509 User Guide an d Specifications 10 ni.com This example assumes the following line connections: • Bits 7, 6, 5, and 4 are connected to data lines from a four-bit TTL output device. The NI 6509 detects any change in the input data so you can read the ne w data v alue. • Bit 1 is connected to a limit sensor . The NI 6509 detects rising edge ...

  • National Instruments NI 6509 - page 11

    © National Instruments Corporation 11 N I 6509 User Guid e and Specifications Digital I/O Connections The 100-pin high-density SCSI conn ector on the NI 6509 provides access to 96 digital inputs and outputs. Use this conn ector to connect to external devices, such as solid-state relays (SSRs) and LEDs. For easy connection to the digital I/O connec ...

  • National Instruments NI 6509 - page 12

    NI 6509 User Guide an d Specifications 12 ni.com Figur e 3. SH100-100-F Connector Pinout Refer to the Signal D escriptions section for information about the signals av ailable on this connector . +5 V P3.0 P0.0 P3.1 P0.1 P3.2 P0.2 P3.3 P0.3 P3.4 P0.4 P3.5 P0.5 P3.6 P0.6 P3.7 P0.7 P4.0 P1.0 P4.1 P1.1 P4.2 P1.2 P4.3 P1.3 P4.4 P1.4 P4.5 P1.5 P4.6 P1.6 ...

  • National Instruments NI 6509 - page 13

    © National Instruments Corporation 13 N I 6509 User Guid e and Specifications R1005050 Connector Figure 4 shows the pin assignments for the R1005 050 cable when connecting to the NI 6509 device. The naming convention for each pin is P X . Y , where X is the port (P) number, and Y is the line number or nam e. Figure 4. R1005050 Connector Pinout Ref ...

  • National Instruments NI 6509 - page 14

    NI 6509 User Guide an d Specifications 14 ni.com Signal Descriptions Table 3 lists the signals and descriptio ns for all signals available on the NI 6509 device. Table 3. NI 6509 Signal Descriptions Pin Signal Name Description MSB LSB 1, 3, 5, 7, 9, 11, 13, 15 P2.<7..0> Bi-directional data lines f or port 2 P2.7 P2.0 2, 4, 6, 8, 10, 12, 14, 1 ...

  • National Instruments NI 6509 - page 15

    © National Instruments Corporation 15 N I 6509 User Guid e and Specifications Power Connections Pins 49 and 99 suppl y +5 V power to the I/O connect or. The I/O connector power has a fuse for overcurrent prot ectio n. This fuse is not customer replaceable. If the fuse is blown, re turn the device to NI for repair. Caution Do not connect t he +5 V ...

  • National Instruments NI 6509 - page 16

    NI 6509 User Guide an d Specifications 16 ni.com Figure 5. NI 6509 Sig nal Connections Protecting Inductive Loads When inductive loads are co nnected to outputs, a large counter-electromotive force may occu r at switching time because of the energy stored in the inductive load. These flyback voltages can damage the outputs and/or the power suppl y. ...

  • National Instruments NI 6509 - page 17

    © National Instruments Corporation 17 N I 6509 User Guid e and Specifications Figure 6. Limiting Flyback Voltages at the Inductive Load Sinking and Sourcing Examples The following sections provide examples of driving a relay less than 24 mA, driving a relay greater than 24 mA, and dri ving solid-state rel ays. Driving a Relay <24 mA Figures 7 a ...

  • National Instruments NI 6509 - page 18

    NI 6509 User Guide an d Specifications 18 ni.com Driving a Relay >24 mA Figures 9 and 10 are examples of conn ecting the NI 6509 to a relay that requires more than 24 mA of current. These examples use an additional transistor circuit. Figure 9. NI 6509 Sinking Connect ion Example, >24 mA Figure 10. NI 6509 Sourcing Co nnection Example, >24 ...

  • National Instruments NI 6509 - page 19

    © National Instruments Corporation 19 N I 6509 User Guid e and Specifications Accessories National Instruments o ffers the follow ing products for u se with the NI 6509. For more information about optional equipment available from National Instruments, ref er to the National Instrume nts catalog or visit ni.com . Specifications This section lists ...

  • National Instruments NI 6509 - page 20

    NI 6509 User Guide an d Specifications 20 ni.com Power-on state ................. ........ ...... .........Inputs high-Z (default), user-selectable input, output 1 or 0 Data transfers .......... ................. ... ........ ....Interrupts, programmed I/O I/O connector ................... .............. .........100-pin female 0.050 series SCSI Di ...

  • National Instruments NI 6509 - page 21

    © National Instruments Corporation 21 N I 6509 User Guid e and Specifications Physical Characteristics Dimensions (without connectors) PCI-6509 .................. .............. ......... 12.4 cm × 9.7 cm (4.9 in. × 3.8 in.) PXI-6509 .................... .............. ....... 16.0 cm × 10.0 cm (6.3 in. × 3.9 in.) Weight PCI-6509 ............. ...

  • National Instruments NI 6509 - page 22

    NI 6509 User Guide an d Specifications 22 ni.com Shock and Vibration (PXI-6509 Only) Operational shock ......... .............. ............30 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27; test profile developed in accordance with MIL-PRF-28800F) Random vibration 5 to 500 Hz, 0.3 grms ............... ......Operating 5 to ...

  • National Instruments NI 6509 - page 23

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e informat ion about Nationa l Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s . For patents covering Nat ...

メーカー National Instruments カテゴリー Network Card

National Instruments NI 6509のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NI 6509の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments NI 6509の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments NI 6509の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments NI 6509の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments NI 6509のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments NI 6509の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments NI 6509デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments NI 6509を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments NI 6509ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments NI 6509の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments NI 6509の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments NI 6509に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments NI 6509デバイスの基本機能を使うにあたってのヒント。 National Instruments NI 6509のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments NI 6509に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments NI 6509のメーカー/サービスへの連絡先に関する情報。

National Instruments NI 6509についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments NI 6509の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments NI 6509で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)