Barnet Ensign Ross ED810の取扱説明書

10ページ 0.08 mb
ダウンロード

ページに移動 of 10

Summary
  • Barnet Ensign Ross ED810 - page 1

    INSTRUCTION MAN UAL ED810 GAS DE TECTOR I N D E X P a g e N o . IMPOR TANT NOTE 2 ATEX REQUIR EMENTS 2 MARKING 3 GENERAL 3 INSTALLATI ON 4 SOLENOI D VALVE 5 SENSORS 6 OPERATI NG INSTRUCTIONS 7 CALIBR ATION - SEMICONDUC TOR 7 CALIBR ATION – HEAD ELECTRONI CS 8 DECLARA TION OF CONFORMI TY 10 ED810 EC- TYPE EXAMINATIO N CERTIFICATE 11 ZB EC- TYPE EX ...

  • Barnet Ensign Ross ED810 - page 2

    ED810 INSTRUCTION MANUAL 27-02-07 2 IMPORTANT 1. The equipment suppl ied must not be m odi fied in any way since modifications will invalidate intrinsic saf ety certification, MCA and Lloyds app roval. 2. Care should be taken du r ing s ervicing as h igh voltages may be present on the ou tput contacts. 3. It is important to note th at the ED810 con ...

  • Barnet Ensign Ross ED810 - page 3

    ED810 INSTRUCTION MANUAL 27-02-07 3 MARKING All units have a rating label which carries the f ollowing important info rmation:- Model type: GAS DETECTOR TYPE E D810 Input voltage: 12Vdc/24Vdc (delete as appropriate) Vmax in; Um: 250V Code: [EEx ia] II C Certificate no. Baseefa03ATEX0507 Epsilon x, gas group II (1) G and category: CE mark ing, Notif ...

  • Barnet Ensign Ross ED810 - page 4

    ED810 INSTRUCTION MANUAL 27-02-07 4 INSTALLAT ION Note only EDL m anufac tured sensor s, which are suita bly certified can be c onnected to the ED810 and fitted in the Hazardous Area. The ED810 control unit and all uncert ified equipment should be located in the Safe Area o nly. Control Unit: The uni t should be mounted in a conv enient posi tion f ...

  • Barnet Ensign Ross ED810 - page 5

    ED810 INSTRUCTION MANUAL 27-02-07 5 In addition to the zene r barrier fuses (which can not be replaced) each se nsor is indiv i dually fused on the base board PCB. I f a sensor fails to respond the nom i nal 5V b etween blue and brown terminals should be checked and th e 160mA quick blow (F ) changed if necessa ry. Sensor Wiring: The Sensor cable s ...

  • Barnet Ensign Ross ED810 - page 6

    ED810 INSTRUCTION MANUAL 27-02-07 6 SENSORS Type EDF 1B, 2B, 3B a nd 3Bfig are sem i conducto r elem ents housed in a certified flam epr oof stainless steel housing . The housing has a male M32 t hread which can be screwe d into a conduit or suitable junction box. The sem iconductor sensors are av ailable in the f ollowing types:- a) EDF1B flam epr ...

  • Barnet Ensign Ross ED810 - page 7

    ED810 INSTRUCTION MANUAL 27-02-07 7 OPERATING INST RUCTIONS When power is first app lied the power light should illum i nate imm edia tely. The A1 and A2 lights of semiconduc tor sensors will illum i nate with in a few seconds and w ill be ready to be reset after a few m inutes, provided the sen sors are in cl ean air. The alarm l ights and re lays ...

  • Barnet Ensign Ross ED810 - page 8

    ED810 INSTRUCTION MANUAL 27-02-07 8 EDS/C and EDS/P Tran smitters INITIAL S ETUP It is vitally im portant that the ED810 an d EDS/C or P transmitter are calibrat ed tog ether ensuring that the ED810 indicates an alarm at the cor rect concentration. After installation is complete the following se tu p procedure should be fol lowed m atching the EDS/ ...

  • Barnet Ensign Ross ED810 - page 9

    ED810 INSTRUCTION MANUAL 27-02-07 9 EDS/P 1. At EDS/P transmitter measure between – I /P and + I/P, ensure voltage reading is i n the range 4.0 – 5.4V with a Dig ital volt meter. 2. Using the Zero adjustment potentiom eter on the EDS/P, rotate cl ockwise until the 50% lamp is just illum inated or 0.3V is m easured on the O/P terminal w.r.t 0V. ...

  • Barnet Ensign Ross ED810 - page 10

    ED810 INSTRUCTION MANUAL 27-02-07 10 Please note the - ED810 EC- TYPE EXAMINATI O N CE RTIFICATE And the ZB EC-TYPE EXAMIN ATION CERTIFICA TE Graphics have been rem oved t o reduc e the size of the d ocument for download pu rposes. The full manual and certificates can be ob tained by contacting Ele ctronic Devices ltd. ...

メーカー Barnet Ensign Ross カテゴリー Carbon Monoxide Alarm

Barnet Ensign Ross ED810のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ED810の取扱説明書
- Barnet Ensign Rossの製品カード
- パンフレット
- またはBarnet Ensign Ross ED810の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Barnet Ensign Ross ED810の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Barnet Ensign Ross ED810の取り付け説明書、サービスマニュアル、簡易説明書、またはBarnet Ensign Ross ED810のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Barnet Ensign Ross ED810の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Barnet Ensign Ross ED810デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBarnet Ensign Ross ED810を使用するのを助ける技術的文書のことです。説明書は通常、全てのBarnet Ensign Ross ED810ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Barnet Ensign Rossの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Barnet Ensign Ross ED810の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBarnet Ensign Ross ED810の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Barnet Ensign Ross ED810に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Barnet Ensign Ross ED810デバイスの基本機能を使うにあたってのヒント。 Barnet Ensign Ross ED810のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Barnet Ensign Ross ED810に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBarnet Ensign Ross ED810のメーカー/サービスへの連絡先に関する情報。

Barnet Ensign Ross ED810についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBarnet Ensign Ross ED810の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBarnet Ensign Ross ED810で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)