Omega Engineering HH501BRの取扱説明書

14ページ 0.18 mb
ダウンロード

ページに移動 of 14

Summary
  • Omega Engineering HH501BR - page 1

    OMEGA HH501AS/HH501BS/HH501AR/HH501BR Digital Thermometer ...

  • Omega Engineering HH501BR - page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing Nor th America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com omeg ...

  • Omega Engineering HH501BR - page 3

    1 The symbol on the instrument indicates that the operator must refer to an explanation in this manual. WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp fle ...

  • Omega Engineering HH501BR - page 4

    2 SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: -OL is displayed. Zero: Automatic. Reading Rate: one time per second. Low battery indication: the " " is displayed when the battery voltage drops below the ...

  • Omega Engineering HH501BR - page 5

    3 ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: 0°C to 1767°C, 32°F to 1999°F Resolution: 1°C, 1°F Accuracy: Accuracy is specified for operating temp ...

  • Omega Engineering HH501BR - page 6

    4 OPERATING INSTRUCTIONS Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. °C °F Selecting the Temperature Scale Readings is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the tempe ...

  • Omega Engineering HH501BR - page 7

    5 MIN MAX record Mode Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading, Minimum reading, "MAX-MIN" reading and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and key and all function key are disabled.The beeper emits a tone when a new minimum or maxi ...

  • Omega Engineering HH501BR - page 8

    6 TIMER STOP-WATCH Mode (for HH501AR / HH501AS) Press TIMER STOP-W key to enter stop-watch mode stop-watch is displayed. Press START/STOP key to toggle stop-watch starts and stops (Time goes up to 19 minutes & 59.9 seconds). Press CLEAR key to display 0.1 second, then press again to zero the stop-watch. Press TIMER STOP-W key again to exit the ...

  • Omega Engineering HH501BR - page 9

    7 SET mode (Relative value set and Hi/Lo Limits value set) 1. Press SET key to enter Relative valuse SET mode (Press ENTER key can escape relative valuse set mode), REL set mode. _ = = =.= is displayed (the ".=" is displayed when you set up the fourth number). Relative value is entered via overlay numbers, when you want to get negative va ...

  • Omega Engineering HH501BR - page 10

    8 Hi/Lo LIMITS mode Press Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode, "LIMIT" is displayed. In the this mode the automatic power-off feature is disabled and other funtion key are disabled, when input temperature value exceed Hi. The beeper emits a continuity pulse tone and "Hi" is displayed, and when input tempe ...

  • Omega Engineering HH501BR - page 11

    9 OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. (NEDA 1604, IEC 6F22). The " " appears on the LCD display when replacement is needed. To replace the bat ...

  • Omega Engineering HH501BR - page 12

    1 HH501(A,B) K / HH501(A,B) J / HH501(A, B)T / HH501( A,B)E HH508BR/HH508/HH509/ HH509R CA LIBRA TION PROCEDURE Note: The following calibration procedure s hould perform only by qualified technicians who have access to the items as fol lowing. Equipment: The class of calibrator ha d better 10 times g reater than the measur ed meter. 1. Set the jump ...

  • Omega Engineering HH501BR - page 13

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warr ants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warr anty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers ...

  • Omega Engineering HH501BR - page 14

    M-3204 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyrometers P ...

メーカー Omega Engineering カテゴリー Thermometer

Omega Engineering HH501BRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HH501BRの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering HH501BRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering HH501BRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering HH501BRの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering HH501BRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering HH501BRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering HH501BRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering HH501BRを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering HH501BRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering HH501BRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering HH501BRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering HH501BRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering HH501BRデバイスの基本機能を使うにあたってのヒント。 Omega Engineering HH501BRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering HH501BRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering HH501BRのメーカー/サービスへの連絡先に関する情報。

Omega Engineering HH501BRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering HH501BRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering HH501BRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)