Honeywell PRO-2200 - page 1
PRO -2200 One Reader Interface Installation Manual P art Number: PRO22R1 TD1147 rev0601 ...
-
Honeywell PRO-2200 - page 2
...
-
Honeywell PRO-2200 - page 3
PRO22R1-Reader Interf ace Introduction i T ab le of Contents W ar nings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v Product Liability; Mutual Indemnification . . . . . . . . . . . . . . . . . ...
-
Honeywell PRO-2200 - page 4
Introduction PRO22R1-Reader Interf ace ii NO TES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ _ ____ ...
-
Honeywell PRO-2200 - page 5
W W a a r r n n i i n n g g s s a a n n d d C C a a u u t t i i o o n n s s WARNING Bef ore installation, TURN OFF the e xter nal circuit breaker which supplies power to the system. Bef ore connecting the device to the pow er supply , verify that the output voltage is within specifications of the po wer supply . Do not apply power to the system unt ...
-
Honeywell PRO-2200 - page 6
Introduction PRO22R1-Reader Interf ace iv CAUTION IF ANY D AMAGE T O THE SHIPMENT IS NO TICED , A CLAIM MUST BE FILED WITH THE COMMERCIAL CARRIER RESPONSIBLE. CAUTION Electro-static discharge can damage CMOS integrated circuits and modules. T o pre vent damage alwa ys f ollow these procedures: Use static shield packaging and containers to tr anspor ...
-
Honeywell PRO-2200 - page 7
PRO22R1-Reader Interf ace Introduction D D i i s s c c l l a a i i m m e e r r Product Liability; Mutual Indemnification In the e vent that a Customer receiv es a claim that a Product or any component thereof has caused personal injury or damage to proper ty of others, Customer shall immediately notify Engineered Systems in writing of all such clai ...
-
Honeywell PRO-2200 - page 8
Introduction PRO22R1-Reader Interf ace vi Shipping Instructions T o ship equipment back to Engineered Systems: 1. Contact the customer ser vice depar tment at 800-323-4576 bef ore retur ning equipment. When calling, please hav e av ailable: • A description of the problem or reason f or retur ning the equipment. • Original purchase order number ...
-
Honeywell PRO-2200 - page 9
PRO22R1-Reader Interf ace Introduction vii O THER W ARRANTIES WHETHER EXPRESS, IMPLIED OR ST A TUT OR Y , INCLUDING IMPLIED W ARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY P AR TICULAR PURPOSE. NO REPRESENT A TION OR W ARRANTY OF THE DISTRIBUT OR SHALL EXTEND THE LIABILITY OR RESPONSIBILITY OF THE MANUF ACTURER BEY OND THE TERMS OF THIS PRO VISI ...
-
Honeywell PRO-2200 - page 10
Introduction PRO22R1-Reader Interf ace viii NO TES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ _ __ ...
-
Honeywell PRO-2200 - page 11
PRO22R1-Reader Interf ace Installation 1-1 Reader Interface (PRO22R1) The PRO22R1 pro vides interfacing to a TTL/Wiegand type reader and door hardware as needed, f or a single door . The Reader Interf ace can accept data from a reader with clock/data or Wiegand interf ace and provides a tri-stated LED control and buzz er control. T wo f orm-C relay ...
-
Honeywell PRO-2200 - page 12
Installation PRO22R1-Reader Interf ace 1-2 The f ollowing circuit is recommended. Locate the protection cir- cuit that is close to the load and one at the PRO22R1 (within 12 inches [30cm]), as the eff ectiveness of the circuit will decrease if it is located f ar awa y . ...
-
Honeywell PRO-2200 - page 13
PRO22R1-Reader Interf ace Installation 1-3 Communication to Controller The Interf ace communicates to a controller via a half duple x multi-drop RS-485 interf ace. The total cable length is limited to 4,000 f eet (1,200 meters). Shielded cab le of 24A WG with charac- teristic impedance of 120 ohm and <13pf/ft capacitance is speci- fied f or the ...
-
Honeywell PRO-2200 - page 14
Installation PRO22R1-Reader Interf ace 1-4 J2 1 2 3 4 5 67 8 1 2 3 4 5 67 8 2400 9600 19200 38400 BAUD RA TE OPEN, NORMAL OPERA TION ADDRES S SELECTION 2 345 6 78 1 ...
-
Honeywell PRO-2200 - page 15
PRO22R1-Reader Interf ace Installation Specifications The Interface is for use in lo w volta ge , class 2 cir cuits only . Ω 1-5 ...
-
Honeywell PRO-2200 - page 16
Honeywell Security & Data Collection 2700 Blankenbak er Pkwy , Suite 150 Louisville, KY 40299 (800) 675-3364 www.honeywellaccess.com ...