CDA HCG 731の取扱説明書

24ページ 1.88 mb
ダウンロード

ページに移動 of 24

Summary
  • CDA HCG 731 - page 1

    Customer Car e Department • The G r oup Ltd. • Harby Road • Langar • Nottinghamshi r e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu GB HCG 7 3 1 .. - HCG 7 4 1 .. C ooking Hobs Manual for Inst allation, Use and Maintenanc e ...

  • CDA HCG 731 - page 2

    2 Important This appliance is designed and manufactur ed solely for the cooking of domestic (household) f ood and is not suitable for an y non domestic application and ther ef ore should not be used in a commercial envir onment. The applianc e guar antee will be void if the appliance is used within a non domestic envir onment i.e. a semi commer cia ...

  • CDA HCG 731 - page 3

    3 Important Saf eguar ds and R ecommendations – Do not carry out any cleaning or maintenance without first disconnecting the appliance from the electrical supply. – During and after use of the hob, certain parts will bec ome very hot. Do not touc h hot parts. – After use alw ays ensur e that the contr ol knobs are in the “ ● ” OFF posi ...

  • CDA HCG 731 - page 4

    4 Featur es and T echnical Data Cooking P oints 1 . Auxiliary burner (A) - 1 ,00 kW 2. Semi-rapid burner (SR) - 1 ,75 kW 3. Rapid burner (R) - 3,00 kW 4. T riple ring burner (TR) - 3,50 kW Contr ol Panel 5. Auxiliary burner contr ol knob (1) 6. Rear left semi-r apid burner contr ol knob (2) 7 . T riple ring burner control knob (4) 8. Rapid burner c ...

  • CDA HCG 731 - page 5

    5 How t o Use the Hob Gas Burners Gas flow to the burners is adjust ed by turning the knobs (illustrated in fig.2) whic h contr ol the valves. T urning the knob so that the indicator line points to the symbols printed on the panel achieves the following functions: – Symbol ● : T ap closed (burner off) – Symbol : High (maximum) – Symbol : ...

  • CDA HCG 731 - page 6

    6 Lighting Gas Burners In order t o light the burner , you must: 1 – Press in the corr esponding knob and turn c ounter -clockwise (fig. 3) to the full flame position mark ed by the symbol and hold the knob in until the flame has been lit. In the case of a mains failure light the burner with a mat ch or lighted t aper . 2 – W ait about ten s ...

  • CDA HCG 731 - page 7

    7 Choice o f Burner The symbols printed on the panel by the side of the knob indicate whic h burner you are contr olling. Choose a suitable burner depending on the cookwar e diameter and capacity. The pan diameter should be suitable for the burner power to mak e the most of the burner's high efficiency and not waste fuel. A small pan does not ...

  • CDA HCG 731 - page 8

    8 WRONG C ORRECT WRONG C ORRECT Corr ect use of T riple-Ring Burner The flat-bottomed pans ar e to be placed directly onto the pan-support. T o use the W OK you need to place the proper stand in order to avoid any faulty operation of the triple- ring burner (Figs. 5a - 5b - 6a - 6b). Important : The wok pan stand (fig. 5b - 6b) MUS T BE PLACED ON ...

  • CDA HCG 731 - page 9

    9 Cleaning and Maintenanc e Gener al Tips – Befor e cleaning the hob switch it off and wait f or it to cool down. – Clean with a cloth, hot water and soap or liquid deter gent. – Do not use products whic h are abrasive, c orrosiv e or chlorine based. – Do not use steel pads. – Av oid using cleaning products with a c hlorine or acidic base ...

  • CDA HCG 731 - page 10

    10 F C Fig. 8 Fig. 7 Burners and Grids – These parts can be remov ed and cleaned with appropriat e products. – After cleaning, the burners and their flame spr eaders must be well dried and corr ectly replaced. – It is v ery important to c heck that the burner flame spreader and the cap have been corr ectly positioned. Failur e to do so can ...

  • CDA HCG 731 - page 11

    11 Corr ect Position o f T riple Ring Burner The triple ring burner must be correctly positioned (see fig. 9); the burner ribs must be fitted in their housing as shown by the arrow . The burner corr ectly positioned must not rot ate (fig. 1 0). Then position the cap A and the ring B (figs. 1 0 - 1 1) A B Fig. 1 0 Fig. 9 Fig. 1 1 Sensor “T” ...

  • CDA HCG 731 - page 12

    12 TIPS FOR INS T ALLA TION Location – The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a r oom or space containing a bath or a show er . – The appliance must not be installed in a bed-sit r oom of less than 20m 3 . – The appliance is designed and approv ed for domestic use only and should not be in ...

  • CDA HCG 731 - page 13

    13 Installation T echnical Inf ormation for the Installer In or der to install the hob into the kitchen fixture, a hole with the dimensions shown in fig. 1 2 has to be made, bearing in mind the following: – Within the unit, between the bottom of the hob and the upper surface of a shelf there must be a clearance of at least 30mm. – It is absol ...

  • CDA HCG 731 - page 14

    14 Applying the Seals – T urn the cooktop upside down. – Spread the longer seal “ A ” ar ound the left, rear and right sides as shown in figur e 1 5a. – With a cutt er or a scissors cut the ex cess seal “ C ” and r etain it for next use (figur e 1 5b). – Spread the seal “ B ” ar ound the left, front and right edges of the cook ...

  • CDA HCG 731 - page 15

    15 Fast ening the Installation Br ack ets Each cooktop is pr ovided with an installation kit including brackets and screws for fastening the top to fixture panels fr om 2 to 4 cm thick. – T urn the cooktop upside down and fasten the brackets “ F " and " R ” to the appropriate socket holes, without tightening the scr ews “ B ” f ...

  • CDA HCG 731 - page 16

    16 Gas Supply Requir ements Important Not e This appliance is supplied for use on NA TURAL GAS or LPG (chec k the gas regulation label attached on the appliance). – Appliances supplied f or use on NA TURAL GAS: they ar e adjusted for this gas only and cannot be used on any other gas (LPG) without modification. The appliances ar e manufactured fo ...

  • CDA HCG 731 - page 17

    17 Gas Connection The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a suitably qualified and register ed installer . Installers shall take due account of the pr ovisions of the relev ant British Standar ds Code of Practice, the Gas Safety Regulations and the Building Standar ds (Scotland) (Consolidation) R egula ...

  • CDA HCG 731 - page 18

    18 Gas connection Cat: II 2H3+ The fitting (fig. 1 7) is made up of: – 1 nut “ A ” – 1 elbow fitting “C” – gasket “F” Connection t o the Gas Supply – Be careful when flexible pipes ar e used that they do not come into contact with moving parts. – T o maintain the thickness of 3 cm, the hob is fit ted with a channel t o co ...

  • CDA HCG 731 - page 19

    19 Con v er sion to Natur al Gas or LPG Replacing the Burner Inject ors If the NA TURAL GAS/LPG conver sion kit is not supplied with the appliance this kit can be purchased by contacting the A fter -Sales Service. Choose the injectors t o be replac ed accor ding to the table below . The injector diameter , expressed in hundr edths of a millimetre, ...

  • CDA HCG 731 - page 20

    20 Regulating the Burner Minimum Set ting When changing from one type of gas to another , the minimum tap output must also be correct, considering that in this position the flame must be about 4 mm long and must r emain lit even when the knob is turned sharply from the maximum t o the minimum position. The adjustment is performed with the burner l ...

  • CDA HCG 731 - page 21

    21 Mains Electricity Connection Incorr ect installation ma y be danger ous and the manufacturer can no t be held responsible. W arning! This appliance must be earthed The manufacturer declines all responsibility f or any problem caused b y failure to observ e this rule. THIS APPLIANCE MUST BE C ONNECTED T O THE MAINS SUPPL Y BY A C OMPE TENT PERSON ...

  • CDA HCG 731 - page 22

    22 Appliance Servicing CDA pr ovide a quality and effective after -sales service to cov er all your servicing needs. Please attac h your r eceipt to this page f or safekeeping. Please help us to help you by ha ving the following inf ormation available when booking a servic e-call: 1 . Model type, make and model – see the product data plat e. 2. E ...

  • CDA HCG 731 - page 23

    23 Guar antee CDA applianc es carry a five-year parts and a one-year labour guar antee. CDA will repair or replac e any defect or part attributable to faulty material or workmanship. Within the first year this will be fr ee of both labour and parts char ges. Aft er the first year and within five years, the parts will be supplied fr ee of c harg ...

  • CDA HCG 731 - page 24

    Customer Car e Department • The G r oup Ltd. • Harby Road • Langar • Nottinghamshi r e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu T o contact our Customer Car e Department, or for Service, please contact us on the det ails below . Cod. 1 1 03535 - ß2 ...

メーカー CDA カテゴリー Cooktop

CDA HCG 731のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HCG 731の取扱説明書
- CDAの製品カード
- パンフレット
- またはCDA HCG 731の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、CDA HCG 731の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、CDA HCG 731の取り付け説明書、サービスマニュアル、簡易説明書、またはCDA HCG 731のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、CDA HCG 731の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

CDA HCG 731デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCDA HCG 731を使用するのを助ける技術的文書のことです。説明書は通常、全てのCDA HCG 731ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

CDAの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. CDA HCG 731の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCDA HCG 731の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。CDA HCG 731に関してこのドキュメントで見つけることができる全てのヒントの目次
3. CDA HCG 731デバイスの基本機能を使うにあたってのヒント。 CDA HCG 731のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。CDA HCG 731に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCDA HCG 731のメーカー/サービスへの連絡先に関する情報。

CDA HCG 731についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCDA HCG 731の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCDA HCG 731で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)